Design standard Multiple chamber incinerator

Waste type organics domestical  waste Calorific value of waste 9,25 MJ/kg Ash content 20.80 % Density 291 Kg/m3 Waste quantity (kg per hr) 12,500 Total Heat input (Gcal/hr) 23.71 organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control Description of the Chimney Top mounted, self supporting Incinerator performance 150kg/hr Refuse  Hospital waste and carcasses Recommended Temperatures Minimum 1000⁰C Dimensions: Length  Width  Height  Extra width for burners At least 3000mm Loading door opening Minimum 700mm x 600mm Hearth area 5.00square meters Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated Primary chamber volume At least 3 cubic meters Mixing chamber volume At least 1 cubic meters Settling chamber volume At least 3 cubic meters Weight excluding chimney 15, 000kg at manufacture Firing tools supplied Hoe, Poker and rake

Precio del incinerador

Descripción del producto Clover suministra incineradores de desechos médicos, crematorios para mascotas y animales, y otros incineradores de desechos sólidos a más de 30 países. Hemos rediseñado la configuración del revestimiento de los incineradores. También hemos diseñado e instalado nuestro propio sistema informático PLC en el sistema operativo del incinerador. Clover sabe que es importante […]

incinérateurs de petite capacité

1 Conception de base de l’installation Une installation approuvée doit avoir quatre sections distinctes qui démontrent que trois principes de turbulence, de temps de séjour et de température sont intégrés dans la conception de l’installation. Les sections réglementées peuvent inclure, mais sans s’y limiter: Disposition générale de l’usine. Chambre d’alimentation / chargement Chambre de combustion […]

Newsletter – waste incinerator

waste incinerator 每天更新 ⋅ 2019年9月23日 www.imcha.net Row as Scottish council sends biodegradable waste to foreign incinerator The Sunday Post A row has erupted over a council’s plans to ship biodegradable waste from Scotland to a Swedish incinerator. With a total landfill ban due in … 标记为不相关 Dozens of people flock to get first glimpse of waste […]

diesel Fuel incinerators

diesel Fuel incinerators 16.  The supplier must provide necessary information for the best of the installation.  This incinerator with “PYROLYTIC”  combustion must have: 17.  A combustion chamber of waste:   Perfectly tight door for the manual loading of waste.  The loading should be manual, batch load.   A burner of lighting which the use is limited to the ignition of waste.   Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out  of refractory.   The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and  insulates bricks in order to assure a minimum temperature on the outside sheet metal.   Composition of the refractory;   Refractory concrete:     Thickness :>100mm     Nature: 42% of Al203   Insulate in fibrous panels:     Thickness: >75mm   Nature: Calcium silicate.   Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of  electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.   Plate of combustion in Carborundum, avoiding the fixing of glass and slags. 18.  A chamber of post combustion of gases   A burner of combustion of gases,   A device of injection of air allowing a total re-combustion of gases,   A device of air inlet of cooling of waste gases,   A sheath of evacuation of the gases burnt,   Carcass in strong sheet steel with support of connection   Composition of the refractory;   Refractory concrete:     Thickness :>150mm     Nature: 65%% of Al203   Insulate in fibrous panels:     Thickness: >85mm     Nature: Calcium   Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition,  permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.   A secondary injection of air to ensure perfect oxygen content.

crémation des animaux en Chine

Le panneau comprendra un compartiment pour la connexion des câbles d’alimentation et de commande. Passage pour câbles d’alimentation et les câbles de commande doivent être réalisés par la partie inférieure du tableau. Le tiroir doit être verrouillé en position isolée par des cadenas. 1.Deux systèmes doivent être installés dans le sud du Royaume d’Arabie saoudite. […]

Municipal Waste Incinerator

Basic Info. Pullution Sources:Solid Waste Processing Processing Methods:Combustion Export Markets:Global Additional Info. Trademark:clover Product Description Program Scope:  1. Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC) Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour Feed Capacity 20kg 40kg 60kg 100kg 200 kg Control Mode PLC PLC PLC PLC PLC Combustion Chamber 100L 210L […]