Day: October 28, 2022

incinerator Model TS150

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service. Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses. WWW.HICLOVER.COM|Waste Incinerators WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters Nanjing Clover Medical Technology Co.,Ltd. Tel:  +86-25-8461 0201    Website: www.hiclover.com   Email: [email protected] Email: [email protected]    

incinérateur de déchets à sac rouge

«Chambre à déchets Capacité de la chambre 300 kg Volume de la chambre .54m3 Taille de la chambre (extérieur) Largeur: 91cm, Hauteur: 86cm Longueur: 152 cm Ouverture de porte 66 x 76 cm Hauteur jusqu’à la porte 84 cm Hauteur au sommet de la pile 5,4 m Taille de dalle suggérée (L xlx épaisseur) 1,8 […]

Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste

Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste. HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator Tel:  +86-25-8461 0201    Mobile: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/  Email: sales@hiclover.com Email: hicloversales@gmail.com   Nanjing Clover Medical Technology Co.,Ltd.   2020-07-21

incinérateur de contrebande medi burn 30

rétention d’air pendant au moins 2 secondes à une température inférieure à 850 ° C, la combustion Afin d’obtenir le bon effet. ? doit être un incinérateur à deux chambres, primaire et secondaire Poêles à combustible ? Les déchets pour réduire le volume initial Possibilité de minimiser (environ 5% de cendres stériles Forme). Objectif: Incinérateur […]

PECIFICATIONS OF A PYROLYTIC MEDICAL WASTE INCINERATOR

An incinerator represents a complete solution to the problem of disposal of all hospital waste types. The liquid fuel is diesel. The incinerator should meet the environment standards.  Expected Technical specifications The incinerator shall be fully self contained.  The incinerator plant shall incorporate a control panel for its operation. On the control panel we shall have a visual display of the chamber temperatures. This visual display must control and monitor the incinerator and his performance. Capacity of destruction in weight shall be 60 Kg/h.  It should be able to operate not less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…  Design Specification : Types A, B, C, D, and E of medical waste  “PYROLYTIC” combustion, by controlling the gasification of waste.  The incinerator must avoid the release of black smoke and fine dust, during the loadings. It shall be able to reduce the volume of wastes by 98%. It shall be able to hold emission in the second burn with gas residence of not less than 2 seconds.  The incineration should be completely free from visible smoke as well as offensive odours.  1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel. The primary combustion chamber shall be constructed from heavy steel plate and the unit is internally lined with a complete layer of hote face refractory and high efficiency insulation.  The Internal diameter of the Chimney at least: Ø 400 and its height: 8 m  The Volume of the combustion chamber at least: 1.200 L  The Dimension of the door for loading in cm at least: 70×70.  Burner operation should be Automatic On/Off   Fuel : diesel Manufacturer to provide  necessary information for the best of  the installation 

Малая ветеринарная инсинераторная установка для сжигания 20 кг в час

Базовая информация. Номер модели: минимальное сжигание отходов в энергетической системе Экспортные рынки: глобальный описание продукта Аналитика международного рынка мусоросжигательного завода Дата. 10 июня 2012 г. Скачать: формат Word / формат PDF Ключевое слово: Малые мусоросжигательные заводы Установка для сжигания медицинских отходов Мусоросжигательная установка для кремации домашних животных Производители инсинераторов Инсинератор – это оборудование для сжигания […]