pictures of 500kg per hour machine
Items/Model TS500(PLC) Picture ![]()
Principle Medical Waste Incineration Treatment how many burners does the primary have
Burn Rate Average 500 kg/hour,if 500kg has 1 burner Feed Capacity Average 500kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2700L Internal Dimensions 190x120x120cm Secondary Chamber 1300L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 3.0Kw Oil Consumption (kg/hour) Average 44(DO) Gas Consumption (m3/hour) *** Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 400L Feed Door 90x80cm Chimney 10Meter Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 15000kg External Dimensions 400x210x300cm(without chimney)
Nanjing Clover Medical Technology Co.,Ltd.
h. include an operator’s manual (in English and French and Spanish).
i. require minimal preprocessing i.e. there shall be no/very limited need for prior sorting, crushing or shredding.
j. be capable of handling mixed solid waste streams and incinerable hazardous wastes as indicated.
k. can accommodate large variations in waste composition and calorific value.
l. allow for batch loading
m. incorporate an Air Pollution Control System suitable for basic emission control
n. have a thermal efficiency of not less than 85%.
o. primary and secondary chambers shall preferably have rounded inside corners to avoid the formation of dead zones or cold pockets
p. have very low levels of unburned material in the slag
q. include a supplement fuel source and storage unit (e.g., diesel tank),
“r. proposals shall include the fuel consumption at the rated capacity
be CE Certified, meet relevant British, EU or American Standards, or equivalent.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | |
| Burn Rate (Average) | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | |
| Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. | |
| Combustion Chamber | 100L | 210L | 330L | 560L | |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | |
| Secondary Chamber | 50L | 110L | 180L | 280L | |
| Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber | |
| Feed Mode | Manual | Manual | Manual | Manual | |
| Voltage | 220V | 220V | 220V | 220V | |
| Power | 0.75Kw | 0.83Kw | 0.99Kw | 1.2Kw | |
| Diesel Oil Consumption (kg/hour) | Ave.8.4 | Ave.10.9 | Ave.13.3 | Ave.16.9 | |
| Natural Gas Consumption (m3n/hour) | Ave.10.1 | Ave.13 | Ave.16 | Ave.20.2 | |
| Temperature Monitor | Yes | Yes | Yes | Yes | |
| Temperature Protection | Yes | Yes | Yes | Yes | |
| Items/Model | TS100(PLC) | TS150(PLC) | TS300(PLC) | TS500(PLC) | |
| Burn Rate (Average) | 100 kg/hour | 150 kg/hour | 300 kg/hour | 500 kg/hour | |
| Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. | |
| Combustion Chamber | 1200L | 1500L | 2000L | 3000L | |
| Internal Dimensions | 120x100x100cm | 150x100x100cm | 170x120x100cm | 210x120x120cm | |
| Secondary Chamber | 600L | 750L | 1000L | 1500L | |
| Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber | |
| Feed Mode | Manual | Manual | Manual | Manual | |
| Voltage | 220V | 220V | 220V | 220V | |
| Power | 1.38Kw | 1.69Kw | 2.57Kw | 4.88Kw | |
| Diesel Oil Consumption (kg/hour) | Ave.20.4 | Ave.24.2 | Ave.33 | Ave.44 | |
| Natural Gas Consumption (m3n/hour) | Ave.24.5 | Ave.29 | Ave.39.6 | Ave.52.8 | |
| Temperature Monitor | Yes | Yes | Yes | Yes | |
| Temperature Protection | Yes | Yes | Yes | Yes | |
HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)
Mobile: +86-138139 31455(WhatsApp)
Website: www.hiclover.com
Email: sales
Email: hicloversales