Blog

Dual Chamber Incinerator available for sale 50-200kgs per hr( in supply).


We supply Double Chamber Incinerator with primary chamber size average 1570Liters and burnning rate 50kgs per hour,100kgs per hour,150kgs per hour,200kgs per hour.

the incinerators are now ready for shipping.

Contact with us for quick respond: +86-13813931455

Secret Product Listing per 01 collection

Trick Burning Chamber

Secondly Burning Chamber

Smoke Filter Chamber

Incinerator PLC Control Situation

Smokeshaft:10.0 Meters

*( upgrade to Stainless-steel, cost-free price)

Italy oil/gas burner: 02 devices

Oil Container (if oil gas): 300Liters

Items/Model

TS150( PLC)

Idea

Waste Incineration Therapy

Shed Rate

Criterion 50/100/150/ 200 kg/hour

Feed Capability

Average 750kg/feeding

Control Establishing

PLC( Programmable Thinking Controller Incinerator)

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Second Chamber

750L

Smoke Filter Chamber

Yes

Feed Setting

Manual

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Usage (kg/hour)

Ordinary 20.4( D.O)

Thermal ability( kw/hour)

166-332

Gas Use (m3/hour)

***

Temperature Level Show

Digital Existing

Temperature Protection

Yes

Oil Storage Tank

300L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature Level

800 ℃–– – – -1000 ℃

secondly. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

Exterior Dimensions

300x160x280cm( without smokeshaft)


hospital burner

Supply, setup and testing of clinical waste burner with a capability of 75 kg/ hr gas (LPG) total with all accessories and also as a result with the chimney based on the technical specs as well as conditions of public wellness
make a space for the incinerator that fit 3 incinerators as in thing 3.1.1 and affixed to the burner room waste store that suit waste for a period of seven days as well as all the buildings of enhanced concrete with preparingg burner building and also shop with all the work of wiring, electrical as well as illumination systems, water supply and also sanitation
supply incinerator building as well as the waste stockroom with a fire extinguish sprinkler system relies on the source of the water from network of teh basic site, along with a fire alarm system contains sensing units for warm, smoke and this system is linked with the medical facility emergency alarm systems
Supply, setup as well as screening of the air flow system of the incinerator room and also the stockroom with fans ROOF COVERING TOP EXHAUET FOLLOWERS offering them with filters with high performance (HEPA FILTER trip to draw fans with taking the air modification price of 5 times per hr with streams and also air required grilles
Supply, setup, testing different conditioning unit for waste database DUCTED SPLIT UNITES and capability enough to maintain the interior temperature level at 14 degrees Celsius in summertime and winter
Supply, installation, screening of the cooling shop of shielded premade wall surfaces inside the waste room with a capacity of 35 cubic meters to conserve the medical waste at a temperature of no Celsius till shedding including the cooling unit and all accessories
UNSAFE wood.
play timber.
petroleum residual waste.
hydraulic hose system.
calcium hydroxide bags.
bags or wooden boxes including cyanide.
medical waste.
filters.
pharmaceuticals.
NO HAZARDOUS sawdust.
plastic.
plastic and also textil awnings.
wood.
plastic bathtubs.
rubber.
hygienic waste.
EPPs.
plastic bags.
building and construction recurring.
infected dustcloths or towels.
plastic or packaging of food.
polyestirene dishes, glasses, spoon, fork, etc.Capacity incinerator clinical waste to high burning temperature level.
With a smokeless gadget to shield the setting as well as with two combustion chambers furnished with gas burners or oil.
– burner to shed large volume items of 70 cm.
discrepancy: Automatic Control System.
– destructive capability from 20 to 30 kgs.
First-room/ Temperature = 900 ° C combustion.
Second room/ Temperature level = 1200 ° c afterburner

конструкция мобильной мусоросжигательной установки

Орган может потребовать, чтобы владелец сертификата прошел испытания, проведенные аккредитованным учреждением, чтобы

определить концентрацию следующих веществ в дымовой трубе и / или на уровне земли.

Кадмий и соединения в виде Cd

Ртуть Hg

Таллий Tl

Хром Cr

Бериллий Be

Мышьяк как

Сурьма Sb

Барий Ба

Свинец Pb

Серебряный Ag

Cobalt Co

Медь Cu

Марганец Mn

Олово Sn

Ванадий V

Никель Ni

Соляная соляная кислота

Плавиковая кислота HF

Диоксид серы S02

  1. Эффективность уничтожения и удаления (DRE) 99,99% для каждого основного органического опасного компонента (POHC) в

подача отходов, где:

DRE = [(Победа – Победа) / Победа] * 100

Где: Win = массовая скорость подачи POHC в потоке отходов, подаваемых в установку для сжигания отходов, и

Wout = массовая скорость выброса POHC в дымовой трубе перед выбросом в атмосферу.

ИНСИНЕРАТОР ДЛЯ ТВЕРДЫХ ОТХОДОВ

1

еа

1,5 MMBtu / час сжигания отходов, обеспечивая 200-250 фунтов / час (90-114 кг / час)

Производительность по переработке смешанных потоков отходов со средней брутто

HHV 5500-8500 БТЕ / фунт

Пакетная операция: прибл. 1,9 yb3 (1,45 м3) за 4-6-часовой рабочий цикл

waste incinerator

Burring Capacity 100/ 200 KG/ human resources Please create your offer here
Variety of Heater 02 Nos Please write your deal here
Incinerator Type Double Chamber
Main Chamber
Secondy Chamber Please write your offer here
Burner Layout Controlled Air Please compose your offer below
Gas to be made use of Gas/ Deisel Please write your offer here
Packing System Guidebook/ Batch Type Please create your offer here
Warmer Time 20 minutes Please create your deal below
Sort of Paint Heat Resistance enamel paint Please compose your offer below.1. Gasoline: diesel

2. Intake: 8-10liter/ hour

3. Ability: to cremate (carrion and also spoils) 350-400kg/ hour

4. Temperature level: 900-1350? C

5. Operation temperature: -30 ~ 40? C

6. Burner weight: 1800-2000 kg

7. Quantity: 0.70-0.80 m/cube

8. Outside measurement: 1.4-1.6 * 1.0-1.15 m (L * W)

Capacidad del calentador de devastación de 350 kg / hora

El baño de sangre diario común implica 120 cerdos. El producto condenado y también los resultados del matadero para su eliminación es de alrededor de 1000 kg diarios.

– – – – – – – – Los residuos serán con sistema de alimentación automático directamente al quemador.

– – – – – – – – El tablero de control estará absolutamente equipado con una vista sinóptica beneficiosa que revele el escenario operativo del conjunto

calentador, así como también atendido por el sistema DCS / PLC.

– – – – – – – – El sistema de calefacción ciertamente se producirá como un sistema empaquetado, con un enlace web eléctrico al final, así como tuberías precableadas

en opciones.

– – – – – – – – Los residuos serán sin duda con el sistema de alimentación automática directamente en el calentador.

– – – – – – – – El tablero de control estará absolutamente equipado con una valiosa vista sinóptica que revela la situación de funcionamiento de todo

sistema de calefacción así como también tratado por el sistema DCS / PLC.

– – – – – – – – El TOC de la escoria y las cenizas de fondo definitivamente será mucho menos del 3% del peso completamente seco.

– – – – – – – – El calentador definitivamente se creará como un sistema empaquetado, con el enlace eléctrico precableado y las últimas tuberías

en la colocación.

– – – – – – – – El quemador ciertamente tendrá un sistema de eliminación de cenizas automático con instrucciones más altas.

en posición.

– – – – El incinerador contará con un sistema de eliminación de cenizas automático con dirección ascendente.

– – – – El quemador ciertamente tendrá un sistema completo de terapia de gases de combustión [pila de derivación para situaciones de emergencia, sistema de enfriamiento de gas,

dos activadores así como también sistema de filtrado de partículas] así como aseguramiento de descargas fuera del quemador.

– – – – Formación de trabajadores de AKU en sitio web.

– – – – El sitio web podría revisarse y también echar un vistazo al fabricante de ATI existente, capacidad 150 kg / h. en 1 día de tratamiento.

– – – – El espacio de las instalaciones existentes está convenientemente disponible en el sótano, 100 ′ ′ Tamaño x 30 ′ grande x 20 ′ Altitud para el segundo incinerador.

– – – – El tamaño actual del conducto de humo es de 12 metros, y también el tamaño es de 24 ″ ″ de diámetro.

Simply just how you can find practical incinerators for your regional site?


The heater with dual/double combustion chamber as well as completely dry filter chamber, two gas burner from

Italy created, hot sale version for little range waste result, the ability is 30kgs per hr

as well as likewise 50kgs per human resources.

Heater is not a cost-effective gadgets, generally the tiny range version’s cost around $5,000 usd per device

We are famous small scale incinerator manufacturer and brand, dispatch incinerator products 
and best services with lower price for customer all around the world.

as well as massive range version’s price even more than $50,000 usd each. Before purchase one system burner,

you have to make clear adhering to products:

A, burn what?

you have to make clear adhering to products:

A, burn what? Incinerator is a incineration tools, function is fire waste. What kind of

waste you want to treatment?

B, tiny or huge? This according to the waste result each day or the waste volume per

feed time, like animal dimension.

C, fuel? Incinerator use oil or gas fuel, usually, gas fuel is cheaper than oil and the smoke

cleaner than oil gas version. Some neighborhood website do not have gas supply system.

As well as other technology items, like power( 220v, 380v), waste feed door kind, burner framework, etc.

WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel: +86 -25 -8461 0201

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm


animal burners up for sale

SMART ASH INCINERATORS FOR THE DISPOSAL OF HAZARDOUS WASTE
? Amount: 20 units
? The Burner works with a 55 gallon open finished steel drum
? The unit operates without fuel and utilized only 120v or 220v electrical power for the blowers
? Unit can melting oil infected waste and also medical wastes with a moisture material of 0 to 15%.
? Each unit is provided with 2 steel drums, to make sure that a spare is readily available.
? Each unit to be provided with suggested spare components.
? Service warranty– minimum one year from invoice as well as approval.
? User’s manual to be offered in French and English

HAZARDOUS WASTE TO BE INCINERATED

Dangerous Solid Chemicals.
Different sorts of flammable solids, made use of textiles, oil and toner cartridges, chemicals for water filtration and also photo consumables, and plastic product, empty steel/ plastic cans that still have residues of dangerous products, oil absorptive

Unsafe Fluid Chemicals.
Mostly various types of Acid, Paint, Varnish, White Spirit, Aromatic-Less Solvents, Artificial Fluid For Brake Solutions, Aircraft De-icing Liquid, Hydraulic And Also Compressor Oil, Freon used in some older refrigeration systems, Pesticide Liquid/Spray, Air Refresh Spray and various other comparable chemicals

Infected Gas.
Mostly diesel or gas contaminated by water or solvents

Used and/or Polluted Oil.
Utilized electric motor oils and/or mineral oils unfit for their originally meant usage. Generally motor/gear box oil (approx. 80%) infected by a combination of white spirit and also acetone (approx. 5%) hydraulic liquid (approx 5%)

Contaminated Water.
Waste oils/water, leaches, hydrocarbons/water mixtures, emulsions and also leachate

Infected Dirt.
Dirt polluted by oil gas of chemicals,.
Soil contaminated that has to be reused in landfill,.
Soil dealt with as well as changed on site

Oil Polluted Solids.
Cloths, absorbents, cardboard, oil and fuel filters, air filters are not considered as unsafe products

Electronic Waste.
Waste electrical or digital appliances or settings up, including printed circuit boards having harmful product and/or hefty metal and/or discharging reduced radiation

Utilized Battery Cells.
Dry battery, ups battery or other kinds unsorted waste batteries/battery cells, having products that are harmful

Used Lead Acid Batteries.
Waste lead acid batteries, drained/ un-drained as well as whole or smashed

Hazardous Medical Waste.
Scientific as well as associated waste emerging from clinical, nursing or similar methods and waste produced in facilities during the examination or treatment of people (biography threat)

Ended Medicines Strong.
Waste drugs, drugs as well as medications, consisting of sensitive medicines

Expired Medicines Liquid.
Waste liquid pharmaceuticals, various type fluid chemicals for treatment, medical oil as well as paraffin based ended medications

Ended and/Or Contaminated Food.
Spoiled fresh food or pointless dish prepared to eat meals (MRE’s) completely dry food

производитель установки для сжигания опасных отходов в Китае

? Сжигайте минимум 80 кг / час X 12 часов в день

? Удаление потоков как неопасных, так и опасных отходов (в соответствии с перечнем отходов)

? Мобильный блок (предпочтение устанавливается на салазках с точками подъема)

Дизайн / Технические характеристики

Мусоросжигательные заводы должны иметь вторичную камеру сгорания с минимальным диапазоном температур 900 ° C

? Потоки жидких отходов должны сжигаться с помощью соответствующей системы впрыска жидкости.

• Мусоросжигательные печи будут оснащены визуальной сигнализацией для предупреждения операций о низкой температуре во вторичной камере.

Рабочая среда и окружающие условия

Блок инсинераторов должен быть спроектирован для работы в следующих условиях:

? Среднесуточная максимальная / минимальная температура июня, 21-39 ° C

? Среднесуточная максимальная / минимальная температура января, 2-12 ° C

8. Инсинератор должен иметь аварийную вентиляцию. Аварийный вентиль должен оставаться закрытым, т.е. не должно быть дымохода

газообразный при нормальной работе инсинератора.

9. Металлический топливный бак из черной стали (емкость не менее 2500 литров) устанавливается в помещении мусоросжигательного завода.

Резервуар должен быть снабжен всей необходимой арматурой, включая линии наполнения, вентиляции, слива и перелива, индикацию уровня.

и доступ для осмотра и обслуживания. Реле уровня должны быть предоставлены для следующих услуг.

(а) Сигнализация низкого уровня

(b) Сигнализация высокого уровня

(c) Запуск перекачивающего насоса на низком уровне

(d) Остановка перекачивающего насоса по высокому уровню

10. Для размещения инсинератора должно быть предоставлено готовое сборное помещение. Помещение будет оформлено таким образом

свободное пространство доступно со всех сторон, а тепловое излучение сведено к минимуму, что позволяет операторам легко

рабочая среда и вентиляция. В материалах будет достаточно конструкционной толщины уголков из низкоуглеродистой стали аккуратно

покрытый грунтовкой по металлу и эпоксидной краской, чтобы противостоять морской коррозии

Сертификат 11.CE и соответствие нормам ЕС

12. Необходимые запасные части для обслуживания и сопутствующие аксессуары должны поставляться с системой сжигания отходов.

Класс 1: промышленные предприятия, сжигающие отходы в качестве дополнительного / альтернативного топлива

Установки для сжигания отходов, в которых отходы служат топливом или дополнительным топливом в промышленном процессе (например, при использовании

цементные печи или любые другие промышленные котлы или печи для удаления ядовитых или опасных материалов).

tiny range incinerator

Incinerators Organic waste disposal system (incinerator)

Burner must satisfy the adhering to specifications:

— Combustion capacity( kW )= 581+/ -10 %

— Combustion capacity( kcal/h )= 500,000 +/ -10%

— Max. l/h( at approx. 50% water content )= 100+/ -10%

Further specifications will be offered with the query.

The burner will be fully self contained.

The burner plant shall include a control board for its procedure. On the control panel we shall have an aesthetic display screen of the chamber temperatures. This visual screen should manage as well as check the incinerator and also his performance.

Ability of destruction in weight will be 60 Kg/h.

It should have the ability to run not less than 10 hours/day

This incinerator must be able to ruin all combustible wastes produced by medical facilities, personal centers, research laboratories, institutes, and so on.

Style Spec: Kinds A, B, C, D, and also E of clinical waste

“PYROLYTIC” burning, by regulating the gasification of waste.

The incinerator need to stay clear of the release of black smoke and fine dust, during the loadings.

It will be able to decrease the quantity of wastes by 98%.

It will be able to hold discharge in the 2nd burn with gas residence of not less than 2 seconds.

The incineration need to be entirely free from visible smoke as well as offending smells.

1.0 The primary ignition heater shall providing ignition of the waste to 850 ° C and must turn off to conserve gas.

The main combustion chamber will be created from hefty steel plate as well as the system is internally lined with a full layer of hote face refractory as well as high performance insulation.

The Internal size of the Smokeshaft at the very least:? 400 and its elevation: 8 m

The Quantity of the combustion chamber a minimum of: 1.200 L

The Measurement of the door for filling in cm a minimum of: 70 × 70.

Burner procedure ought to be Automatic On/Off Fuel?: diesel

Manufacturer to give necessary details for the very best of the installment

The control board shall have all suitable audible and aesthetic alarms to make sure safe operation.

This burner with” PYROLYTIC “burning need to have: 1.
A burning chamber of waste: oPerfectly tight door for the hands-on loading of waste. The loading should be Manual, Set Load oA heater of lighting which the use is restricted to the ignition of waste. oFrontage of loading with door seals increased on joints, wheel of screw plug, flexible joint, as well as stuffing protecting out of refractory. oThe insulation of the burning chamber need to be composed of refractory bricks, having a high web content of aluminium as well as insulates bricks in order to ensure a minimum temperature outside sheet metal. o Structure of the refractory;

? Refractory concrete:. Density: ≥ 100 mm. Nature: 42 %of Al203? Insulate in fibrous panels: Thickness: ≥ 75 mm Nature: Calcium silicate.? Burner of illumination of waste, with fuel, conventional mono-bloc spreading directing plunging fire, illumination and also safety and security of digital ignition, irreversible ventilation,
electromagnetic sluice gate of regulation and isolating valve.
Plate of combustion in Carborundum, preventing the fixing of glass as well as slags

A chamber of post burning of gases oA heater of burning of gases, oA gadget of injection of air allowing a complete recombustion of gases, oA tool of air inlet of air conditioning of waste gases, oA sheath of discharge of the gases charred. oCarcass in solid
sheet steel with assistance of connection. oComposition of the refractory;? Refractory concrete:? Thickness: ≥ 150 mm? Nature: 65% of Al203? Insulate in fibrous panel:? Density: ≥ 85 mm? Nature: Calcium oBurner with gas, mono-bloc spreading directing kind with straight flame, illumination as well as safety and security of digital ignition, long-term ventilation, electromagnetic sluice entrance of regulation and also separating shutoff.
oA second shot of air to guarantee excellent oxygen material.

A control box guaranteeing the complete cycle of combustion.

Follower: oElectro-ventilator dispersing the second air, the regulation of the air circulation being carried out by valves and also adhering to the control of the automated cycle. Controls and also guidelines: Control box watertight to dust, consisting of:

A button circuit breaker for every engine (ventilators as well as burners). A timer with flexible temporization for the guideline of each burner. A regulator with watch for the temperature level of burning. A regulatory authority with digital watching for the temperature of message burning. Electric box

The secondary
burning chamber should damage the pollutant item and must resist to high temperature( 1100 ° C)

Refine Filtering system: Scruber to be mentionned as optional

Waste burners extra components


HICLOVER now supplies additional components including:

— — — — Burners (diesel oil, LPG or gas)

— — — — Facet for heaters

— — — — Fire ropes

— — Incinerator chamber maintenance items

— — — — Air Follower