Blog

clinical facility incinerator manufacturers


SCHEDULE 2

  • TECHNICAL SPECIFICATIONS OF THE INCINERATOR
  • General Description

Previous experience in the supply, installment as well as appointing of burners

  1. Overall plant layout
  2. Feed chamber/charging
  3. Primary combustion chamber
  4. Particulate scrubbers
  5. Acid gas
  6. The stack/chimney.
  7. Minimum capacity of primary chamber = 10cubic meters
  8. Burn rate (rate of waste incineration) = 10 kg per hour
  9. Should have a full width counterbalance loading door allowing easy access to the main chamber for loading and removing ash.
  10. The INCINERATOR should be NEMA approved in accordance with Environmental management and coordination (Waste management) Regulations of 2006.
  • Scope Of Work

at least10kg per day

  1. Supply, install and commission an incinerator as provided   in the technical specifications
  1. Provision for adherence to OSHA and other statutory requirement relating to Health and Safety of workers during execution of the works covered in this
  1. Assessment and preparation  and construction of  a standard incinerator shed with one waste  storage room  ( see the design )
  1. Provision of operation and maintenance manuals and drawings complete with maintenance schedule and
  1. Fuel oil storage tank- Mild steel 1000 liters capacity
  1. Onsite training for operation and maintenance

Basic Strategy design to Supply Overall plant layout.

Genuine estate center with one waste storage room

Deal Real estate designs with ideal cross air circulation

  1. TECHICAL SPECIFICATIONS OF THE INCINERATOR

Chamber (Afterburner Optimum departure temperature must not be much less than 1100oC

Security interlock, Fan Newbie, Heating System on/ off switch/door safety button, Vehicle layer button, temperature levels regulate device.

  • Primary Combustion
  • This chamber should be equipped with burners that use low sulphur
  • The chamber should ensure a minimum exit temperature of 850 degrees
  • This unit should operate at over 1100 deg C to ensure complete
  • This chamber should be equipped with burners that use low sulphur
  • Heavy-duty steel casing
  • High quality refractory lining and insulation
  • Large full size top load door and liquid retention
  • 1 x oil fired ignition burners operated on/off
  • Secondary Combustion Chamber (After burner)
  1. Heavy-duty steel casing
  2. High quality refractory lining and insulation
  3. 1 x oil burner
  4. Should be fitted with burners that use low sulphur
  5. Ensure secondary air supply is controlled.
  6. Ensure residence time is not less than two seconds.
  7. Ensure that the gas temperature as measured against the inside wall in the secondary chamber and not in the flame zone is not less than 1100 degrees
  8. Ensure the emitted oxygen content of the emitted gases is not less than 11%
  9. Ensure both primary and secondary combustion temperatures are maintained until all waste is completely
  • Particulate Removers

Key Combustion Chamber Minimum departure temperature level need to not be much less than 850oC

  1. Cyclone separator
  2. Electrostatic precipitators
  3. Fabric filters
  • Chimney/Stack
  1. The chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all The topography and height of adjacent buildings within 50 meters radius should be taken into account.
  2. The chimney should be visible to the operator from the feeding
  1. The minimum exit velocity should be 10 meters per second and at least twice the surrounding wind speed (Efflux velocity = wind speed x 2) whichever is higher to ensure no down washing of exiting
  2. The point for measurement of emissions shall be
  • Instrumentation
  1. Instrument for determining the inside wall temperature and not burner flame temperature must be provided for both primary and secondary
  2. An audible and visible alarm must be installed to warn the operator when the secondary chamber temperature drops to below the required
  3. A carbon monoxide and oxygen meter/recorder should be
  4. A smoke density meter/recorder should be
  5. A solid particulate meter/recorder should be
  6. Any other instrument that may be considered
  • Location / Siting of the Incinerator
  1. a) The incinerator must be sited in accordance with the relevant local municipal authority planning regulations and the topography of the site must be compatible with premises in the
  • Emission Limits
  1. Combustion efficiency (C.E) shall be at least00% where C.E = %Carbon dioxide x 100 / [% Carbon dioxide + carbon monoxide]
  2. The temperature of the primary chamber shall be 800 +/- 50 degrees centigrade
  3. The secondary chamber gas residence time shall be at least 1 second at 1050 +/- 50 degrees centigrade with 3% oxygen in the stack
  4. Opacity of the smoke must not exceed 20% viewed from 50 metres with naked
  5. All the emission to the air other than steam or water vapour must be odourless and free of mist, fume and
  6. A 99.99% destruction and removal efficiency (DRE) for each principal organic hazardous constituent (POHC) in the waste feed where DRE [ ( Win – Wout) /Win ] x

Second Burning Optimum leave temperature level need to be not a lot less than 1100oC

  1. The average dioxin and furan concentration in the emission should not exceed 80mg/m3 total dioxins and furans if measured for a period of 6 to 16
  • Ease of Use
  1. Auto
  2. No pilots to
  3. Automatic control and temperature monitoring
  4. Built-in skid facilitates placement
  • Fuel Efficiency
  1. Rapid incineration means low fuel
  1. Up to 20kgs per hour (dependant on application).
  2. Thick refractory lining rated to 1400 deg C in main chamber retains heat, increasing
  • Quality Built to Last
  1. Heat resistant 3mm
  2. Stainless steel
  • Key Features
  1. Low running and maintenance costs
  2. Fully Automatic and simple to operate control panel
  3. Afterburner Preheat
  4. Incineration Temperatures in Excess of 900 degrees C
  5. 3 mm Steel Casing and Fully insulated
  6. Dense Refractory Concrete Lining Rated to 1400 degrees C
  7. Solid Hearth to Allow Maximum Burnout
  8. Large Top Opening Lid For Easy Loading
  9. Stainless Steel Flue as standard
  10. 12 Months or 1000 hours
  11. Optional Stainless Steel Casing
  12. Heat Recovery System option
3.13 Fuel and Capacity  
1. Low sulphur fuel
2. Capacity (Cubic Mtr) .10
3. Average Capacity 40kg
4. Fuel Consumption (ltrs / hr) 3
  • External Dimensions
1. Length (mm)               735  
2. Width (mm)                500
3. Height Incl. Flue (mm) 1960
4. Door Opening (mm) 325 x 325
  • Internal Dimensions
1. Length (mm) 620
2. Width (mm) 390
3. Height 500
  • Operation
  1. Minimum Operating Temperature 950
  2. Maximum Operating Temperature 1320
3. Burn rate per hour 5-20kgs
4. Temperature Monitoring Available
  • Particulate Removers

SECTION VII

  1. Cyclone separator
  2. Electrostatic precipitators
  3. Fabric filters
  • Chimney /Stack
  • The chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all The topography and height of adjacent buildings within 50 meters radius should be taken into account.
  • If possible the chimney should be visible to the operator from the feeding
  • The addition of dilution air after combustion in order to achieve the requirement of these guidelines is
  • The minimum exit velocity should be 10 m/s and at least twice the surrounding wind speed (Efflux velocity = wind speed x 2) whichever is higher to ensure no down washing of exiting
  • Point for the measurement of emissions shall be
  • Control Panel
  1. Control of 2 burners
  2. Timer control 0- 12 hours
  3. Integral fan timer control
  4. Temperature and thermostatic control

COST TIMETABLE FOR THING

NO: REQUIREMENTS SUPPLIER’S REMARKS
1. Experience

Price schedule for Supply, Installment, Checking out as well as Appointing of an incinerator for Turkwel Power Terminal

 
2. 1 Year Maintenance Contract  
3. Work rate

WONDERFUL BARGAIN

 
4. Design

1

49,50,51,60,61,77,78,79,80,81,100

ENTIRE WHOLE LOT

GREAT DEAL

Offer Housing styles with appropriate cross air flow

Chamber (Afterburner Maximum departure temperature should not be less than 1100oC

 
5. Standard control panel

Security interlock, Follower Beginner, Heater on/ off switch/door safety switch, Car fold button, temperature levels regulate device.

 
6. Combustion Chambers

Key Combustion Chamber Minimum departure temperature level must not be much less than 850oC

Second Combustion Optimum leave temperature level need to be not much less than 1100oC

 

SECTION VII

PRICE SCHEDULE FOR ITEM

Rate schedule for Supply, Installment, Examining as well as Commissioning of an incinerator for Turkwel Power Station

1 2 3 4 5 6
Item Description Unit of sale Quantity Unit price Total price
1. Supply, install, and commission the incinerator as specified. LOT 1    
2. Construct a standard incinerator housing facility as per the drawing and architectural notes provided  

GREAT DEAL

 

1

   
4. Construct one  waste  storage  room (provide specs on room size, construction material etc) LOT 1    
5. Supply / adhere to  the requirement of OSHA 2007 act

49,50,51,60,61,77,78,79,80,81,100

LOT 1    
6. Onsite training of Operation and Maintenance staff. LOT 1    
7. All the key Spares (Attach a separate List) LOT 1    
8. Supply and install 1000 liters Fuel oil storage tank and its secondary containment with Diesel oil level indicator and necessary piping with valves for visual checking of fuel level. LOT 1    
9. Supply of Operation and Maintenance Manuals.  

WHOLE LOT

1    
10. All other items not specified but necessary to complete the Installation.   A separate list of these items to be attached.  

LOT

1    
11. Fencing of  a compound  of 10 meter length  by 10 meter  width   using Concrete  poles  high Gauge mesh wire , and a lockable gate. (Indicate size and design of gate) LOT 1    
  Sub Total        
           
  Discount  (%) if any        
  Applicable Taxes and Duties        
           
  Total Cost in Kshs        


medical waste incinerator china

medical waste incinerator china, Design, supply and manufacture ex works of one Surefire Manual Load TS50/1 Medical/General waste incinerator as detailed below: –

·         Waste type: Mixed type o,1,2,3,&4 hospital/clinical bio hazard waste

·         Waste density: 125 to 350Kg/M3

·         Waste CV: 4000 KCAL/kg

·         Moisture content: 10-25%

·         Estimated ash residue: 5-10%

·         Nominal capacity: 30Kg/hour batch load

·         Secondary chamber: 0.5 second @ 850oC
·         Compact laboratory style

·         Two combustion chambers

·         Ecologically friendly

·         Up to 50kg of waste / hour

·         To be used for animals

Clover Medical Incinerators

Product Description

Nanjing Clover Medical Technology Co., Ltd., Neighborhood in Nanjing city, China.

CLOVER supply medical equipment, medical waste incinerators, pet animal cremator, other solid waste treatment equipment, clean room equipment, fan filter units, air filter, etc.. We supply technology assistance, installation service and client produced. 

We’re one of the most significant waste incinerator producer and exporter of China. Pyrolytic incinerator specialized is primary waste treatment method all over the world, for Medical Waste, Animal Incineration, Pet cremation and other good waste. Currently we supply small and large scale incinerators as local client requirements and layout updated incinerator with our top technology. 

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Nanjing Clover Medical Technology Co., Ltd.  Tel: +86-25-8461 0201  Fax: +86-25-8461 0406

Containerized Mobile Incinerator Medical Waste Incinerator Model CA50

HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50


Model

CA50

Picture

Waste Treatment

Medical Waste Incineration Treatment

Feed Capacity

Average 100 kgs per feeding

Burning Rate

Average 50 kgs per hour

Burning Time per Feed

Average 2 hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Voltage

220V

Power

1.0 Kw

Gas

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Temperature Monitor

Digital Screen

Fuel consumption (Oil)

Average 16.9 Kgs/Hour

Internal Dimensions

100x80x70cm (Primary Chamber)

External Dimensions

230 x 130 x 155cm (main body)

Waste combustion chamber

560Liters

Post Combustion Chamber

280Liters

Oil Tank Capacity

200 Liters

Door Opening

70 x 50cm

Chimney

5.0M

Gross Weight

4500kgs

Chamber Material

Firebrick,Refractory Concrete

Max.

166,000Kcal/Hr.

Operation Technical Specifications

Solid Chamber temperature

8000C -10000C

Gas Chamber temperature

10000C -12000C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning efficiency

>98%

Waste Lower Calorific Power

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Small Medical Waste Incineraotr for COVID-19 Bio Hazardous Medical Waste

HICLOVER – Medical Environmental 

Model

YD-20

Picture

Burning Rate

Average 20 kgs/hour

Feed Capacity

Average 60 kgs/feeding

Primary Combustion Chamber

360 Liters

Secondary Combustion Chamber

200 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

1.0 Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 13.3 kg/hour

Gas Consumption (Natural Gas )

***

Internal Dimensions

100 x 60 x 60cm (primary chamber)

External Dimensions

145 x 90 x 260cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if Petroleum fuel)

200 Liters

Door Opening

48 x 60cm

Chimney Length

5.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

2300 kgs

Operation Technical Specifications

Primary Chamber Temperature

800℃–-1000℃

Secondary Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Burning Efficiency

>98%

Waste Lower Calorific Power

3000Kcal

Wearing a face mask to keep out the coronavirus has become an essential part of everyday life for many people 
around the world, but the huge amount of waste being created as the single-use items are tossed aside has the 
potential to become an ecological disaster.

How to deal with discarded face masks, which number in their millions or even billions, is another headache for 
Chinese authorities already caught between containing the viral disease and limiting the economic damage caused by it.

The country’s inadequate medical waste treatment capabilities have also been put under the spotlight, environmental experts said.

Environment and health authorities say masks and other protective gear, especially items used by medical personnel and 
people infected with the coronavirus, should be treated as clinical waste, and sterilised before being incinerated at high 
temperatures at dedicated facilities.

While it is difficult to get an exact figure on the number of discarded masks, it is reported that the volume of medical 
waste in Wuhan, the city in which the epidemic began in December, had quadrupled to more than 200 tonnes a day last 
week, according to mainland Chinese media reports.

The total amount of medical waste gathered across Hubei province on February 24 totalled 365 tonnes, of which 60 per 
cent came from hospitals, the report said.

By comparison, Wuhan produced 17,000 tonnes of medical waste in the whole of 2018, according to the country’s top 
environment watchdog.

Eric Liu, a toxic waste specialist at Greenpeace’s Beijing office, said China had a huge shortage of waste disposal facilities, 
specifically those capable of handling clinical waste.

“The waste treatment capacity in China, especially in terms of medical and hazardous waste, is barely enough to cope 
with everyday needs, let alone the country’s biggest public health crisis in decades,” he said.

While the environment ministry said most medical waste was being properly dealt with in major cities, just 31 per cent 
of the country’s 629,000 tonnes of medical waste were treated in 2015, up from 24 per cent in 2008, Xinhua reported 
last year, citing an industry study.

Du Huanzheng, director of the Recycling Economy Institute at Tongji University in Shanghai, also expressed concerns 
over the widening supply-demand gap in medical waste treatment, but said a large number of new facilities were being built or planned.

“The disposal of medical waste is a major part of the battle against the outbreak, which is a wake-up call for the government 
to speed up the construction of new facilities and research into waste treatment technologies,” he said.

The coronavirus outbreak could be the catalyst for expanding the medical waste sector and lead to the building 
of more incineration facilities, the experts said.

They said combustion remained the preferred means for disposing of medical waste in China, although industrialised 
countries were phasing out incinerators due to health and environmental concerns.

Masks could be split into three categories, Liu said. While clinical waste must be disposed of at dedicated incineration
 facilities, masks used by healthy people could be tackled in a similar way as household waste, which was burnt in industrial furnaces, he said.

The real challenge came from those used by people who were placed under home quarantine or others with mild symptoms, he said.

“There is a grey area over this kind of used mask, which are not under the jurisdiction of medical institutions but should 
be treated in accordance with standards for medical waste.”

In Wuhan, authorities are scrambling to find solutions to the challenge. The environment ministry said the city’s five incinerators 
for household waste disposal and various industrial furnaces at cement and other factories had also been assigned to help clear 
the garbage backlog, which stood at about 190 tonnes as of February 24.

According to a report by China Economic Daily, Wuhan is rushing to build more medical waste treatment plants near hospitals, 
including ones near Huoshenshan, Leishenshan and Jinyintan hospitals that will treat nine, 15 and four tonnes of clinical garbage respectively on a daily basis.

A total of 17 temporary storage facilities for medical waste, with a combined capacity of more than 1,000 tonnes, have also been built.

While authorities had to transfer some of the garbage produced in Wuhan to neighbouring cities for incineration, they have also 
tried to enlist help from waste treatment companies around the country.

China Shipping Group and a company in Anhui deployed a number of mobile medical waste incineration cabins to Wuhan last month, Xinhua reported.

The incinerators, each of which is capable of processing five tonnes of waste a day, were first used in 2003 during the Sars outbreak.


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

Высокоэффективный фильтр V-типа

2019-05-13 Воздушный фильтр342 просмотра


Ecolea d высокоэффективный фильтр V-типа

Особенности продукта:

л    Наружная рама: пластиковая рама, оцинкованная рама, рама из алюминиевого сплава или рама из нержавеющей стали

л    Материал фильтра: ультратонкое стекловолокно или полипропилен.

л    Разделитель: термоклей

л    Максимальная температура: 80 ℃

л    Максимальная влажность: 99%

л    Эффективность: 99,99% @ 0,3 мкм (H13) 99,999% @ 0,3 мкм (H14)

Приложения:

л    Широко используется в очистном оборудовании для кондиционирования воздуха с большим объемом воздуха

л    Области, в которых предъявляются строгие требования к чистоте воздуха, например, терминальная фильтрация систем кондиционирования воздуха.

Кривая зависимости начального сопротивления от объема воздуха

Общие технические характеристики и параметры производительности

тип    номер

Габаритные размеры

Морской узел    Состав

Рамка    тело

Площадь фильтра

(м 2 )

Номинальный объем воздуха

(м 3 / ч)

Падение начального давления

(Па)

Ш × В × Г (мм)

F8

H10

H13

МВ1212-2ВФ25

287 × 287 × 292

287

Одинарный выпуклый

25мм

2В

Пластиковый каркас / металлический каркас

4.2

800

110

180

260

МВ1220-2ВФ25

287 × 490 × 292

7,7

1200

МВ1224-2ВФ25

287 × 592 × 292

9,4

1600

МВ2012-3ВФ25

490 × 287 × 292

490

Одинарный выпуклый

25мм

3В

Пластиковый каркас / металлический каркас

6.4

1100

МВ2020-3ВФ25

490 × 490 × 292

11,6

1900 г.

МВ2024-3ВФ25

490 × 592 × 292

14,4

2400

МВ2412-3ВФ20 / 25

592 × 287 × 292

592

Одинарный выпуклый

20/25 мм

3В

Пластиковый каркас / металлический каркас

6.4

1100

МВ2420-3ВФ20 / 25

592 × 490 × 292

11,6

1900 г.

МВ2424-3ВФ20 / 25

592 × 592 × 292

14,4

2400

МВ2412-4ВФ20 / 25

592 × 287 × 292

4В

Пластиковый каркас / металлический каркас

8,4

1600

МВ2420-4ВФ20 / 25

592 × 490 × 292

15.4

2500

МВ2424-4ВФ20 / 25

592 × 592 × 292

18,8

3200

МВ2412-5ВФ25

592 × 287 × 292

592

Одинарный выпуклый

25мм

5В

Пластиковый каркас / металлический каркас

10,5

1800

МВ2420-5ВФ25

592 × 490 × 292

19.0

3200

МВ2424-5ВФ25

592 × 592 × 292

23,5

3900

МВ1212-2В

305 × 305 × 292

610

Коробка

2В

Пластиковый каркас / металлический каркас

5,4

850

МВ1224-2В

305 × 610 × 292

10,8

1700

МВ2412-4В

610 × 305 × 292

4В

Металлический каркас

11

1700

МВ2424-4В

610 × 610 × 292

двадцать два

3400

МВ2412-5В

610 × 305 × 292

5В

Пластиковый каркас / металлический каркас

13,5

2100

МВ2424-5В

610 × 610 × 292

27

4200

МВ2412-6В

610 × 305 × 292

6В

Металлический каркас

16

2500

МВ2424-6В

610 × 610 × 292

32

5000

1. В случае изменения спецификации и структуры, последние данные, предоставленные нашей компанией, имеют преимущественную силу.

2. Компания принимает заказы на фильтры, не указанные в таблице.

URL с дополнительным содержанием: www.ecolead.cn Тел: 025-57138032

incinérateurs dans 3 établissements pour raffiner les déchets de soins médicaux

une. 2,5 charges métriques par jour brûleur de déchets de soins de santé

b. Brûleur de déchets de soins de santé de 1,5 tas par jour

c. Brûleur de déchets de soins médicaux de 300 kg par jour

Notre technologie préférée est l’incinération à double chambre, mais si vous suggérez une technologie moderne différente, c’est acceptable.

Nous demandons des informations sur les éléments suivants pour chacune des demandes ci-dessus:

1. Coût en capital (dépense fournie à Oman)

2. Frais de fonctionnement et d’entretien (annuellement)

3. Nombre de pilotes demandés

4. Spécifications de l’article (tailles, niveaux de température, temps de la maison, temps de cycle, etc.)

5. Divers autres équipements auxiliaires nécessaires ou recommandés par vous

Waste Incineration HICLOVER Model TS75

Waste Incineration HICLOVER Model TS75 

Items/Model

TS75(PLC)

Picture

Principle

Waste Incineration

Burn Rate

Average 75 kg/hour

Feed Capacity

Average 150kg

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

770L

Internal Dimensions

100x81x95cm

Secondary Chamber

385L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.7Kw

Oil Consumption (kg/hour)

Average 16.9

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

100L

Feed Door

99x91cm

Chimney

3Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800℃–-1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

4500kg

External Dimensions

2.30mx1.30mx2.55m

15kg-20kg LPG driven Clinical waste incinerator to burn highly infectious materials
100kg per hour *medical incinerator* is needed in the size of a *20ft container.* 
100Kg/Hour Burning rate with
       with Secondary burning Capacity
Je suis intéressé par votre produit Longue durée de vie Pet Crematory (YD-15), je veux savoir plus de détails sur:
Veuillez me proposer une liste de prix précis.
Ce serait formidable si vous pouvez me faire parvenir plus de détails sur ce produit.
Human Cremator For Crematorium Cremation Machine 
Automatic Medical Waste Incinerator with Auto Loading Systems.
The working capacity 150 KGs EACH BATCH
incinerator to be used for medical/clinical wastes incineration 

mobile incinerator china

Temperature:  ambient temperature ranges between 21 – 450  C or more in poorly ventilated rooms. The hottest month

of the year is March. Environmental temperature can be such that inferior rubber and plastic materials can easily melt

or deformed. Bidders must ensure all materials will be able to withstand such temperatures

 

4)  Humidity: humidity is usually high about 65 – 90%. Electronic units must be protected to prevent the effect of

condensation.

 

5)  Dust: this is a major problem especially during the dry season. Dust get into equipment and clogs up filters.

Additional protection must be provided where necessary and where applicable spare filters supplied to last not less

than five years continuous use.

 

6)  Vermin: these are also available and occasionally enter into equipment to chew cables and urinate on boards to

cause short circuit. This can be prevented by providing vermin guard where necessary to prevent entry of such

destructive animals.

7)  The proposed equipment must conform to the current relevant international standard such as ISO; CE; IEC, ANSI

and/or BS

 

8)  Language:

  1. a) All labels and markings on the equipment must be in English language. b) All software programmes in the proposed

equipment must be in English

language

手動經濟型卷繞式過濾器

2019年05月10日 自動卷繞式過濾器 446 views


產品簡介:

手動搖卷繞式過濾器實際上為了節省客戶經費,一種簡易型的捲簾空氣過濾器產品,主要特點是節約了自動控制的功能,人力搖動手輪實現了濾料更換的過程。 

工作原理

主要是由濾料、傳動系統及自動控制系統組成。

新過濾材料裝在上料箱,當進風帶有高濃度含塵空氣通過卷繞式過濾器后,過濾器前後壓差隨濾塵增加而逐步上升;當過濾器阻力上升到設定的終阻力值時,壓差開關開始動作,卷繞系統更新濾料;當達到捲簾時間,停止傳動,更新濾料工作完畢,重新進行過濾。 

產品特性:

*結構堅固,可以滿足最惡劣的工作環境

*人力更換濾料,有效節約能源,降低成本

*模塊化的設計能夠滿足任意類型的系統設計和安裝要求

*低中高端不同材質和配置備選,滿足客戶差異化需求

材質:優質冷軋鋼板烤漆、鋁型材或SUS 304

控制:手動

濾料:專用覆網過濾材料,G3、G4(EN779)效率

安裝:成品出貨現場只需通電便可運轉,若因現場安裝空間限制可散件包裝發運,貨到現場即可靈活拼裝成型 

產品應用:

*對潔凈室新風進行空氣大顆粒物進行有效的過濾器,提供更加合格的空氣進入潔凈室內部;

*有效防止空調的新風口周圍出現污漬的表象,廷長後段中效高效過濾器的使用壽命;

*有效防止污水處理廠鼓風機積灰嚴重,安裝在鼓風機前端對鼓風機給予有效保護;

*對於化工廠、紡織廠、噴塗車間等空氣過濾器系統進行初效過濾,去除大部分的顆粒物,有效提高排出廢氣和循環氣體的質量。

產品尺寸與風量參數表

註:1.以上風速@2.5m/s時計算得出的風量值 

    2.當寬度>06ft需分為多台拼裝

    3.可為客戶提供各種非標尺寸定製

標準圖紙

更多內容 網址: www.ecolead.cn 電話: 025-57138032