Containerized Mobile Incinerators

○ Containerized Mobile Incinerator(CA Model)

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.

Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce.

 

※Main Feature:

— Double Combustion Chamber

— Double Italy Burner

–Burning Rate: 10-100kgs per hour

–Combustion Chamber: 0.1M3-1.2M3

— Mobile Incinerator, Standard shipping containers, Easy to move/transport system

— Free Installation, Pre-installed incinerator, Ideal for camps

— Ultraviolet lamp sterilization inside

※Optional Function/Parts/Material/Burning Rate:

— Stainless Steel Chimney

— Dry Smoke Filter Chamber

— Chimney Height Custom Made

— Upgrade/Downgrade Burning Rate

déchets de risque de soins de santé ainsi que brûleur de déchets de base

Nous recherchons une croissance durable, par conséquent, nous adoptons un système de surveillance des déchets médicaux durable, qui comprend la construction d’un incinérateur moderne et durable qui ne fournira certainement pas seulement notre centre, mais aussi les nombreux autres centres situés dans la zone plus grande du site. Type de déchets: déchets dangereux pour les soins de santé et déchets standard
5. Cheminée:
Arbre de fumée: acier léger de 3,5 mm
Altitude à partir de la base: 11 m et en plus s’il y a des structures à l’intérieur
30 m de l’appareil de chauffage, l’arbre de fumée doit s’étendre d’au moins 3 m
au-dessus des sommets de toutes les toitures de tels bâtiments
Taille de l’arbre de fumée en tête: 430 mm.
Poids de la pile: ± 500 Kg.
L’instance et la pile doivent être repeintes avec de la peinture noire immunisée à la chaleur à 400 ° C.
6. Systèmes de chauffage:.
Première chambre 850 ⁰ C—- 900 ⁰ C.
deuxième chambre 1000 ⁰ C.
7. Souffleurs d’air à débit variable.
8. Quantité de la chambre principale ± 1,05 mètre cube.
9. Quantité de la chambre de mélange ± 0,30 mètre cube.
10. Traitement de la quantité de chambre ± 0,89 mètre cube.
11. Poids sans arbre de fumée ± 6 400 kg à la fabrication.
12. Outils de tir fournis: Hoe, Texas Hold’em en plus du râteau.
13. Dimensions.
Dimension ± 2125 mm.
Taille ± 1890 mm.
Élévation ± 2125 mm.
Dimension supplémentaire pour les brûleurs ± 1000 mm.
14. Ouverture de la porte d’emballage 610 * 540mm.
15. Superficie du foyer ± 1,19 mètre carré.
16. Résumé de la grille / foyer: Un foyer total à fournir pour éviter d’être contaminé.
17. Les fluides s’écoulent directement dans la fosse à cendres sans être brûlés.
18. Conformité à la loi sud-africaine sur la prévention de la contamination atmosphérique n ° 45 du.
1965 ou critères de contamination de l’air égaux.
19. Documents à fournir: Traitements et manuel d’entretien avec demande.
traitements courants (SOP).
20. Commandes d’échappement:.
écran réfractaire chauffé.
Chambre de nettoyage des grains à taux réduit.
Affichage du parafoudre en acier inoxydable

21. Produit réfractaire: teneur en alumine>>>> 49% ainsi que densité commune de 102 mm.
22.: à corriger 2-3 jours.
23. Produits de structures.
Boîtier: acier modéré de 5 mm.
Soutenant: angle lourd et même réseau.
Foyer: 1550 ⁰ C.
Porte cendrée: fonte de haute qualité.
Porte d’emballage en acier modeste de 5 mm revêtu de béton réfractaire monolithique à haute résistance et à haute résistance à l’abrasion.
Surfaces de la paroi du brûleur en plus du revêtement du toit: réfractaire monolithique coulable 1550 ° C

Veterinary Incinerators

Product Description

From 17th May, 2013, company name change to be”Nanjing Clover Medical Technology Co., Ltd.”  The former company”Clover Medical Limited” exists as a subsidiary company. 

Incinerator is a incineration equipment, direct fire waste from the combustion chamber amount capacity, the price of animal crematory, the tempreture of the stoker moving grate incinerator, the waste oil stove gasoline ignition pdf, gasoline fuel or oi gas. As different circumscription, incinerator could be named many words as below: 

Therapy capacity: Small scale incinerator, big scale incinerator and incineration pant. 

Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 

Incinerator gas: Gas incinerator, oil incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator producer, UK incinerator producer, USA incinerator producer, India incinerator manufacturer. 

Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 

Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Incinerador de dos cámaras

Información básica.

Fuentes de extracción: procesamiento de residuos sólidos
Métodos de procesamiento: combustión
Mercados de exportación: Global

Información adicional.

Marca registrada: trébol

Descripción del producto

Nanjing Clover Medical Technology Co., Ltd. es un fabricante líder de incineradores de desechos en China. Somos fabricantes locales y uno de los mayores exportadores de China. El equipo técnico de incineración pirolítica es el principal tratamiento de desechos en todo el mundo, para desechos médicos, incineración de animales, cremación de mascotas y otros wste sólidos. La capacidad de 10kgs / Hr. Hasta 500kgs / Hr., Hasta 6ton por día. Actualmente, suministramos a uzbekistán distribuidor médico, crematorios veterinarios, incineradores veterinarios, equipos de cremación, crematorios veterinarios, crematorios de hospitales veterinarios, diferentes series para los requisitos del cliente local y un incinerador de diseño actualizado con nuestra tecnología líder. La característica de diseño actualizado de nuestra gama de incineradores los convierte en uno de los más rentables del mundo.

Artículo Especificación
Modelo YD-30 YD-50 YD-100 YD-150 YD-300 YD-500
Tasa de quema 30kgs / hora 50kgs / hora 100kgs / hora 150kgs / hora 300kgs / hora 500kgs / hora
Lista de productos principal Cámara de doble combustión
Cámara de mezcla de combustión
Cámara de filtro de humo
Caso de control
Apilar
Quemador de gasoil / gas Italia: 02 unidades
Tanque de aceite (si es combustible de aceite)

Крематорий для мелких животных Оборудование

Базовая информация.

Номер модели: стоимость инсинератора со скоростью загрузки 20 кг / час.
Источники очистки: переработка твердых отходов
Методы обработки: сжигание
Экспортные рынки: глобальный

описание продукта

Ответ по технологиям (FAQ)

В: Какие отходы можно использовать в этом оборудовании?
A: Это оборудование для медицинских отходов, домашних животных, бытовых отходов, живых отходов. Запретить любые взрывчатые и радиационные материалы, жидкие отходы и газовые отходы.

Q: Стандарт дыма из инсинератора
A: Стандарт правительства Китая: № GB18484-2001.

Q: способность лечения
A: Средняя мощность, рассчитанная по медицинским отходам (низшая теплотворная способность (LC P): 3,0TH ккал / кг в час), не означает никаких отходов. Скорость сгорания животных / домашних животных составляет около 2/3 средней мощности.

Время использования инсинератора Clover в сутки до 24 часов. Между каждой загрузкой / сжиганием есть время охлаждения примерно 0,5-1 час и время для загрузки отходов. Фактическое время горения в день составляет около 16 часов. Срок службы инсинератора от 5 до 10 лет в зависимости от использования.

Как правило, мы предлагаем небольшую лабораторию, небольшую клинику с производительностью до 20 кг в час. При использовании инсинератора в больнице, пожалуйста, рассчитайте производительность отходов около 2 кг на человека в день. Если в больнице 200 коек, это означает, что вам нужна одна мусоросжигательная печь мощностью около 400 кг в день, изменение производительности в час составляет около 30-40 кг в час. В зависимости от продолжительности работы в день, отходов, бюджета, развития и т. Д. Вы можете использовать установку для сжигания отходов от 30 до 50 кг в час.
* Как рассчитать уровень сжигания кремации животных: 2/3 медицинских отходов.

Q: Сборка и тестирование
О: Мы поставляем всю документацию и инсинераторы, простые в установке и эксплуатации. Малогабаритная медицинская установка для сжигания отходов, интеллектуальная установка для сжигания золы, установка для сжигания 30 кг в час, установка для сжигания животных на продажу, установки для сжигания отходов, установки для сжигания отходов на продажу. Заказчик может отправить людей на наш завод для ознакомления с установкой и работой. Как правило, мы не отправляем инженера на местный объект, если нет запроса. Стоимость отправки оплачивается дополнительно в соответствии с заказом.

Q: Температура сгорания
A: Первая камера сгорания: 800-1000 градусов сантиметра.
Вторая камера сгорания: 1000-1200 градусов санти.

В: Режим управления инсинератором
A: Режим управления по умолчанию – это общий случай управления. Режим ПЛК в зависимости от модели и заказа.

В: Затраты на эксплуатацию и техническое обслуживание
A: Стоимость эксплуатации в зависимости от расхода топлива и мощности / персонала и т. Д.

Ежегодное обслуживание от 500 до 1000 долларов США в год в зависимости от модели и ситуации использования.

Один человек может обслуживать мусоросжигательные заводы 02 блока. Персонал должен обладать базовыми знаниями электрика для эксплуатации / проверки / обслуживания инсинератора / горелки / воздуходувки в соответствии с инструкциями по эксплуатации, а также знать риск медицинских отходов, чтобы защитить себя с помощью необходимых элементов защиты.

Q: Время пребывания во вторичной камере сгорания
A: 02 сек.

Предметы Технические характеристики
Скорость сжигания 10 кг / час 20 кг / час 30 кг / час 50 кг / час 100 кг / час
Модель TS10 (ПЛК) / TS20 (ПЛК) / TS30 (ПЛК) / TS50 (ПЛК) / TS100 (ПЛК)
Список основных продуктов Двойная камера сгорания
Камера дымового фильтра
Случай управления режимом ПЛК
Дымоход из нержавеющей стали
Горелки дизельные / газовые, Италия: 02 шт.
Масляный бак (если жидкое топливо)

Newsletter – incinerator

Google
incinerator

Medical Waste Incinerators ⋅ 2019年9月24日
www.imcha.net

Plans for an incinerator at a former steel works have been approved despite objections from nearby heritage sites, schools and a council.
Facebook Twitter 标记为不相关

Global Incinerator Market Expert Insights 2019. If you have heard about the Incinerator market, then you know the Incinerator Industry is growing at a …
Facebook Twitter 标记为不相关

The objective of Incinerator Equipment Market Report provides a complete decision-making overview including definition, market gains, key …
Facebook Twitter 标记为不相关

A crucial report on Waste Incinerator Market provides comprehensive insights that allow to everyone to understand particular things of Waste …
Facebook Twitter 标记为不相关

Before the vote, Cameron defended the incinerator against those who say it’s not safe for the environment, and blasted the slate of lawmakers whose …
Facebook Twitter 标记为不相关

Dataintelo’s latest research report on ‘Medical Waste Incineration Equipment Market’ delivers a comprehensive study on current market trends.
Facebook Twitter 标记为不相关

Before the vote, commissioner Cameron defended the incinerator plant against those who claim it is harmful to the environment: “This last session, the …
Facebook Twitter 标记为不相关
查看更多结果 | Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)
Newsletter。

|
RSS 以RSS Feed的形式接收此快讯

发送反馈

small waste incinerator for ZAMBIA model YD30C

YDC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. 
This equipment quality structural for kinds of site, like hospital, environmental department, animal cremation agencies, 
etc. CLOVER Incinerator supply updated models with dual combustion chamber, mix combustion chamber and smoke 
filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.

Items Specification
YDC Model YD-10C / YD-20C / YD-30C / YD-50C
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel:  +86-25-8461 0201   

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 2100 kgs 2100 kgs 2300 kgs 2500 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃

Floor Weighing Scale
“A digital weighing scale is needed to accurately weigh the wastes before entering the sterilizer. All the components of the plant are at the same ground level, so the balance should allow weighing the cart with wastes easily then roll it into the sterilizer.The size of the balance platter are left to the supplier as they will depend on the sizes and weights of the provided carts. Minimum size will be 900X550X6 mm.The power in the building has a voltage 200-240, therefore, the scale should work safely with this power and in addition should satisfy the following: 
? Durable construction with Stainless Steel Platter 
? Bidirectional RS-232 data interface 
? Easy-to-read 1″” / 25.4 mm high LCD Display with Backlight 
? Weighing units conversion through keypad: kg, lb, oz, counting 
? Auto zero tracking 
? Stability and low battery indicator 
? Overload and underload indication 
? Auto off (battery) 
? Power: AC/DC Adaptor 12VDC Operating Temp.: 5-35 °C. Digital indicator can be wall mounted and is connected to the weighing platform by a spiral extension cable (Length >1 m)
“
Truck cleaning set
A basic truck cleaning system shall be offered, consisting of a supply of surface disinfection chemicals, a knapsack sprayer and a high pressure cleaner. The containers shall be sprayed by a surface disinfection solution, will be scrubbed and afterwards finally cleaned with the pressure cleaner. 200 litre of approved, concentrated surface disinfection solution shall be supplied. 
The knapsack sprayer shall be of daily commercial use type and come with standard accessories: Pivoting stainless steel spray lance, flexible high-pressure hose, easy-press trigger gun,  shoulder strap and hand spray gun. The tank volume should be not less than 5 l with a maximum pressure of 5 bar.  It shall be a steel sheet container, hot-dip galvanizes with manometer, bleeder valve, TüV and GS certificated and different kinds of nozzles as accessories.
The high-pressure cleaner shall be delivered with the cleaning equipment. Power supply shall be 1/230/50 (~/V/Hz), the water flow rate should be about 230-560 l/h and the operating pressure  30-130/3-13 (bar/MPa . The max. water feed temp. shall be 60 °C.
Radiation detector  
“A mobile, hand-held radioactive detector shall be supplied to check the radioactive wastes in the medical wastes and to prevent radioactive wastes from entering the system. The acquired information must be recorded to the system automatically. The detector must warn both auditory and visually.
“
It should have two electrodes and be able to be adjusted according to beta and gamma rays and it must be approved by an Atom Energy Institution. 
Monitoring package
A one year supply of monitoring equipment and consumables for monitoring shall be supplied together with the plant. The package shall include 2500 standard chemical indicators test stripes (indication of successful reaching of the treatment temperature by colour change).
300 biological spore test (Bacillus Stearothermophilus) and one incubator for spore test (55°C). The biological spore test shall be adjusted for the chosen treatment temperature and time.
52 standard Bowie Dick test set (non-reusable) for the test of successful air removal (only if the treatment plant is using a vacuum process) 
Personal Protection Equipment 
Sets of PPE designed for the working with bio-hazardous materials (Risk level I to&nbsp
;III) shall be provided. Each set shall include at least: one pair of safety boots (size to be determined later), one overall (size to be determined later), 30 masks, 1 pair needle stick proof Gloves, 3 goggles. 
The needle stick proof gloves shall be made with a Nitrile Butadiene coating (water repellent) which shall cut down penetration by blood and body fluids, sewage etc. The inner Gloves are made from knitted Kevlar for cut resistance, and have more than 350 elasticated steel Teflon platelets incorporated into them to stop needles penetrating. Test Standard: Injection Needle, DIN 13097, ISO 7864.
Sets of PPE designed for the working with steam treatment plants shall be provided. Each set shall include at least: one pair of safety boots (size to be determined later), one overall (size to be determined later), 30 masks, 1 pair Heat resitant gloves, 3 goggles. 
“Heat resistant gloves, Made from Kevelar, Application: Personal Protection Equipment for the loading / unloading of waste bags in incinerators, autoclaves, etc, 
? High heat resistant
? Good protection against cuts
“
Waste disposal equipment
Cart-Hydraulic loader (hydraulic operated bin lift-tip device)
“External, moblile lift tipping device with a control system. Must come with a hydraulic power pack consisting out of an electrical motor with oil-pump working with a centrifugal fan pump. Hydraulic valve shall direct the flow of oil so that the tilting structure moves upwards or downwards when pressing the corresponding push-button switches. Effected by two-hand operation. The device shall be designed to emptying the treatment container of the reatment plant directly into the waste skip without spillages.
“
“Width x Depth x Height: about 2 x 1.8 x 3.4 m
Minimum lifting capacity 500 kg
Electrical Data >2 kW
220C240 V/50Hz
Tilting Height >1.7 m”
Waste Skip (5,5 m3)
“Waste Skip (container) with 2 hatches
Volume: 5,5 m3, Liquid proof
Built in accordance with DIN 30720
Materials
Bottom C Mild steel – 5mm
Sides C Mild steel, 4mm
Hatch C Mild steel- 2,5 mm.
Reinforcement  RSC 76mm x 38mm x 6.7kg/metre
Lifting Lugs: 4 no Shepperd Meiler type manufactured skip lugs welded through both the channels and side plates
Tipping Bars 35 mm mild steel tipping bar with FLT6 mm pressed plate supports
Hatches to be fitteld with a detachable handle to ease opening, each hatch shall be fitted with 2 steel hinges and secured using a hasp and staple to which a padlock may be fitted
One coat primer, two coats finishing enamel in colour of your choice.
Anticorrosion protection: One coat primer, two coats finishing enamel in light green (RAL) 
Each dump hatch shall be equipped with a spring for facilitating opening
Containers should be equipped with effluent grate with drain valve. “
Deposit Tipper Truck
“Truck:
Should have a wheel base of >2750 mm.
Load capacity >5 tons
Cabin type: single cabin  
Engine capacity: >100 Kw, Fuel type: Diesel  
Gearbox kind: Manual, Number of Gears: 5  
Power steering: yes  
Number of seats: 2 with appropriate seat belts, with Sun Visor
Cloth Seat Covers and rubber floor mats (ruffnuts).
Front & rear mud flaps.
Lockable fuel cap, factory type where applicable.
Should come with an Hour meter.
Spare tyre and rim. jack, wheel brace and spanner. A spare tyre carrier is also to be fitted.
Provide two (2) amber revolving lights, both to be fitted permanently on cabin or roof bar. “
“Deposit tipper mounting:
For carriages up to 3 tons total weight to transport skips ranging from 1.5 to 7 cbm.
Compact design for good manoeuvrability. 
The system should work with two separately operated rotating arms and a telescoping equipment which enables stacking of containers
Expansion to the left and to the right should be separately operated, skip should be able to be clamped on to the loading area. 
Should come with two built in front stoppers which secure the skip to the front.
An additional securing with straps or chains should not be necessary.”
Other Works
Supply, install and operate Ventilation Works:
A complete washable aluminum centrifugal fan with its own electric motor, vibration stoppers,and air cleansing filters,according to the specifications and as follows: 280 m3/min at a 50 mm water static external pressure.  
A complete washable axial exhaust fan with rain protective cover and its own electric motor, according to the specifications and as follows: Ex-1 fan 70 m3/min at a 50 mm water static external pressure.  
0.7 mm galvanized iron sheets air passages with 
controllers according to specifications and industry standards.    
Un-painted Aluminum air outlets with the dimensions shown in the drawings and according to technical specifications.  
Supply and install a cold storage room
“Supply and install a modular storage cold room including cooling system with a size of about 4m x 6m and about 2 m high. The temperature in the cooling room shall not be more than 7°C. The cold room shall be constructed of prefabricated insulated panels. The panels should be fire resistant Class 1, the refrigeration equipment should be ‘CE’ approved and appliance tested at point of construction or after installation.
“
“The exterior height of the room including floor and ceiling panels shall be 2000 mm. Corner panels shall be formed in one piece for greater strength and ease of installation. Panels shall be of foamed-in-place polyurethane, which will be blown using, CFC/HCFC agent sandwiched between galvanised steel substrate minimum 0.6mm thick and the outer surface will be white polyester.
The polyester thickness shall be minimum 25mm and with a smooth finish for ease of cleaning. Edges of all panels including wall/wall, wall/corners, wall/ceiling, wall/floor shall be male, female jointed to give good insulation factors and be equipped with cam action locking devices to all sections, locking devises to be foamed-in-place at time of fabrication.”
“Floor panels shall be same as wall panels with the addition of marine plywood surface coated with a non-slip glass fibre resin suitable for pedestrian traffic and trolleys with rubber wheels. Floor panels to be capable of supporting 250kg per 0.145 m2 evenly distributed when panels are fully supported. 
Insulation Factors:
Each panel shall be completely filled with rigid CFC/HCFC Free polyurethane foam to a density of no less than 40kg/m’ and having a thermal conductivity of 0.28 w/m2 k. The panels will also have: –
A.    Coefficient of thermal conductivity of gn = 0.024 w/mk
B.     Coefficient of thermal expansion n.70 x 10-6/k
C.    Water vapour transmission rate (0,1…1,2) x 10-12kg m/m2 sPa
D.    Water absorbency in 100% relative humidity max. 0.2 volume%
Overall thickness of each panel is 100mm. “
“The assembly of the cold room shall be accomplished by excentric action cam lock panel fasteners. These shall be foamed in place and activated by hex key wrench provided with each cold room. All butted joints on exterior where visible and all interior joints should be sealed by silicon mastic provided with the room, to ensure no debris or dirt can accumulate at any time.
The cold room shall be equipped with one (1) semi-rebated hinged door complete with heavy duty hinges and lockable door handle, fitted with a luminous emergency entrapment release, which will override the locking mechanism. Door gaskets will be of a pullout push-in type for easy field replacement. Door surround and threshold will be in stainless steel Grade 304. The door shall provide a clear opening of minimum 900 X 1900 mm. The door blade will be of the same finish as the room panels supplied.”
“The room shall be fitted with an on-board air cooled refrigeration system capable of holding waste at the required temperature of +6 to +8°C The unit shall be manufactured to take up the full length of a panel and take condenser air from the coolest area i.e. Bottom of unit. The condenser will be fitted with a filter, which can be removed for easy cleaning. The unit shall be selected to operate in ambient temperatures of Yemen. A control panel shall be incorporated to include a digital temperature display that will be easily adjusted to the required temperature.
The refrigeration system should use environmentally friendly refrigerants. The unit shall also be supplied with bulkhead light and light on/off switch. “
Civil Works:Execute all the civil works according to specifications:
Reinforced concrete for the hall floor, including a layer 15cm thick of plane concreted and stone. 
Supply and install an epoxy-insulating layer on the hangar-lab floor at the rate of  0.5 litre/m2 over the lightly reinforced concrete with all necessary requirements for the conclusion of works according to the drawings and specifications, and the instructions of the supervising engineers.
Plastering work according to specifications
Supply and install ceramic tiles similar to the existing one for the walls of the hangar in accordance to specifications. 
Supply, install, operate, testing and handing over the electrical works inc
luding all work requirements such as plastic pipes, wires, cables, switches, sockets, and whatever needed according to the European specifications and norms. The contractor shall be responsible in case of supplying apparatuses or materials that are not approved by the management or the supervising engineer:  
An armed copper ground cable (7x240mm2+1x240mm2) extending from the transformer to the main board. The price covers excavation and back-filling, the warning strip, pipes, and whatever needed for concluding the job according to the drawings, specifications, and the supervising engineer’s instructions.
Ditto, but cross section (4x70mm2+25mm2)
Ditto, but cross section (4*70mm2)
Ditto, but reinforced with the cross section (4*25mm2 + 16mm2)
Ditto, but normal with the cross section (4*25mm2 + 16mm2)
Ditto, but  normal with the cross section (4*16mm2+10mm)
Ditto, but reinforced with the dimension (4*16mm2+10mm)
Armed copper ground cable (4×10 + 6mm2) for lightening the site and the fences. 
A complete earthing system 
Supply, install and operate a main distribution board with 10 lines, 800 ampere equivalent to Legerand type or ABB.The item includes the installing of the board on a concrete base with room partition.It shall include:
One (800 A) 3 Ph MDB 
One (2×160 A) 3 Ph Branch C.P.
Two (2×100 A) 3 Ph Branch C.P
Four (4×63,3 A) 3 Ph Branch CP
The contact breakers shall be of the MCCB type. 
A normal 80 Watt 50 cm dangling lamps from the roof 
125-Watt halogen down light systems, with an arm, and an internal and external wall base.
 35 cm-diameter fans for drawing air out at the café and WCs
15 Ampere 220 V 3-openings electric socket with switch 
 20 Ampere 220 Volts electric socket with a red indicator
Supply and install a telephone socket at the hall and management room
Supply, install and operate a fire alarm and fire fighting system including all parts and accessories required to operate the system in accordance with the drawing and specifications:
A sensitivity scalable T type Ionization smoke detector that works in air-conditioned and non-conditioned spaces including its complete cables in reinforced pipes.
A heat detector that is sensitive to the rapid rise of temperature and can work with a stable pre-determined controllable temperature, complete with cables in reinforced pipes.
A sirne should be installed to work automatically through the detectors and the volume level can be varied between 85:95 db according to the drawing complete with its cables.
A break glass according to the drawing and specifications.  
A fire alarm control pannel complete with cables in reinforced pipes.
Fire fighting foam in full 25kg containers with carrying wheels of a guaranteed source with all accessories
Fire fighting dry powder in full 6kg containers, of a guaranteed source complete with carrying frame and all accessories 
Telecommunication: To connect the office building to the telephone network and to install one switchboard for at least 2 lines. 
Operate and maintain the whole plant for one month including training the management local staff on its operation and maintenance through out the one month. 

incinérateur de déchets scientifiques en vente

Type de déchets: déchets de soins de santé
Densité des déchets: 125 à 350Kg / M3
Valeur calorifique des déchets: 4000KCAL / kg
Contenu Web d’humidité: 10– – 25%. Dépôt approximatif de cendres: 5– – 10%. Capacité nominale: lots de 50 kg / h.
2ème chambre: 2 [e-mail protected] C.
Environnement: NEMA ACT (EMCA) 1999, Waste Keeping track of plans, 2006.
Trick Burning chambre:.
La principale chambre de combustion est la structure importante de l’appareil de chauffage, produite à partir d’une plaque d’acier modérée en plus de zones en acier laminé.

Il est porté à partir du niveau du revêtement de sol sur une structure de support en acier considérable. L’intérieur du revêtement est doublé d’un isolant en silicate de calcium ainsi que d’une combinaison de visage chaleureux de maçonnerie incroyablement engageante ou de moulage à haute résistance.

La chambre de combustion principale doit s’assurer que le niveau de température de séparation minimum n’est pas beaucoup moins de 850? C.
Un brûleur de lots manuel constituant:.
Porte de chargement à commande manuelle.
Cheminée droite forte, chambre de combustion primaire revêtue de réfractaire. Approximatif. dimensions 800x2100mm (DxL).
Porte de chargement massique / d’élimination des cendres.
1 brûleur d’allumage diesel – – gestion du niveau de température.
1 suiveur d’alimentation en air de combustion ainsi que système de distribution, contrôle automatisé.
Deuxième chambre de combustion de grande capacité avec un temps de séjour très peu inférieur à 2 secondes @ >> 850? C.
1 post-combustion au diesel– – température régulée.
Panneau de contrôle – – traitement automatisé.
Indicateur de température supplémentaire et chambres primaires 0-1200? C.
Cheminée à brides à revêtement réfractaire à une élévation de 10 m au-dessus du niveau du sol.
NB: La chambre de combustion supplémentaire doit s’assurer que le niveau de température du gaz mesuré par rapport à la paroi intérieure de la 2ème chambre & & & & pas dans la zone d’incendie, n’est pas inférieur à 1100? C

Débit: 50 kg / h à une faible valeur calorifique de 4000 kca / kg ainsi qu’une densité de masse typique de 120 kg / m3 pour les déchets fondamentaux en plus de 160 kg / m3 pour les déchets de soins de santé.
Cendres: Les déchets seront abaissés de 90 ~ 95% pour laisser 10-5% de cendres.
Critères Qualité / Environnement: NEMA ACT (EMCA) 1999, BS3316.
Période de fonctionnement: préparée pour une période de fonctionnement quotidienne de 8 heures.
Durée maximale de fonctionnement: 12 heures.
Chambre: doit être doublée réfractaire à la liste ci-dessous besoin;.
Foyer ainsi que section abaissée supplémentaire des surfaces de la paroi de la chambre.
Article de visage chaud:.
Brique réfractaire super obligation.
Restreindre la restriction de solution constante 1500? C.
Epaisseur: 100 mm.
Conductivité thermique: 1,3 W / mk.
Isolation:.
Silicate de calcium.
Limiter la limite de solution continue 1000? C.
Densité: 25 mm.
Conductivité thermique: 0,095 W / mk.
Cheminée / cheminée: Doit être fabriqué à partir d’acier modeste doublé réfractaire ou de superbes s / s refroidis par air de haute qualité.
La cheminée / cheminée doit avoir une hauteur minimale de 10 m au-dessus du sol.
Unités de chauffage à allumage: type d’huile entièrement emballé, dans l’ensemble avec allumage électrique en plus des commandes anti-incendie, câblées avec suiveur à fonctionnement continu en plus de compléter avec tous les arrêts, ventilateur ainsi que moteur électrique.
Score optimal: un minimum de 450 kW / h.
Chauffage: configuration de la procédure marche / arrêt.
Consommation maximale: au moins 6 L / h.
Apport typique: un minimum de 3 L / h.
Postcombustion:.
type d’huile entièrement emballé, total avec allumage électrique ainsi que des commandes de travail coupe-feu supplémentaires, câblées avec un ventilateur en fonctionnement continu ainsi que toutes les vannes, le ventilateur ainsi que le moteur en plus.
Puissance optimale: au moins 450 kW / h.
Unité de chauffage: aménagée pour traitement marche / arrêt.
Utilisation maximale: au moins 9L / h.
Usage courant: au moins 4,5 L / h.
Thérapie des gaz de combustion: devrait avoir un éliminateur de particules (épurateurs).
Alimentation électrique: étage solitaire: 220 / 240VAC; 50 / 60Hz

Documents:.
chauffe-déchets scientifique à acheter Manuel de procédure: 2 collections.
Manuel de service / maintenance: 2 jeux.
Certification: certification NEMA (ou autre identifiée).
Capacité à résoudre les outils: l’agent / fournisseur disposera de suffisamment de centres, de pièces supplémentaires, de consommables ainsi que d’une équipe technique qualifiée également certifiée.
Formation: l’agent exécutera une formation de 2 jours sur les chauffages après l’installation et la sélection des appareils.

Le représentant fera certainement une formation sur la procédure et l’entretien de 2 jours aux travailleurs de la conception biomédicale après l’installation et la nomination des appareils.

SUPPLY, INSTALLATION AND COMMISSIONING OF WASTE INCINERATOR – TECHNICAL SPECIFICATIONS

SUPPLY, INSTALLATION AND COMMISSIONING OF WASTE INCINERATOR – TECHNICAL SPECIFICATIONS
The Waste Incinerator is designed to burn Type IV of pathological waste and infectious, contaminated “red bag,” surgical dressings, plastic test devices and other wastes. 
General Specifications
Burner:  2 burners (primary burner and second burner)

Fuel: Oil 
Capacity (Cubic Mtr): 0.65 
Ave Capacity: 60 kg per hour 
Fuel Consumption (ltrs / hr):13 
External Dimensions
Length (mm): 2300 
Width (mm): 1220 
Height Incl. Flue (mm) 7000 
Door Opening (mm) 610 x 710 610 x 710
Operation
Min. Operating Temperature: 950 
Max. Operating Temperature: 1320 
Residency Time in Second Chamber: 5 sec 
Temperature Monitoring: YES 
Other clarification
Easy and safe operation
Large counter-balanced fill door with electrical    lockout.
Automatic control system provides preset burn times and shut off. 
Reload light indicates to operator when it is time to recharge. 
Be required for burnout of final charge.  
Low energy consumption levels 
Programmable digital temperature controls maintain temperature, assuring complete combustion while conserving fuel. 
 Pressure blower with modulating air control creates turbulence and distributes combustion air to secondary chamber. 
 Secondary burner with temperature activated modulating control provides fast preheat and   sustains high temperature performance at low energy consumption levels.  
Charging rate 

Up to 600kgs per ten-hour day of Type IV pathological waste or red bag waste rated at 2200 BTU’s per kg, based on batch loading twice daily.
Thermocouples (2 pcs/ each thermocouple assembled on the unit )
Thermocouples with pocket (1 pcs/each burner )
Nozzles (2 pcs/burner)
Nozzle line (1 pc/burner)
Glass fibre (2 roll/size)
Ignition electrode ( 2 pcs/burner)
High tension cable ( 2 pcs/burner)
Flame photometer (1 pcs/burner)
Burner primary chamber (1 set)
Burner secondary chamber (1set)
Control panel parts (1 set)
Fuse (1 pk from each rating )
Solenoid valve (1 pcs/assembled on the unit)
Burner oil filter  (10 pcs/burner)
Fuel pump (1 pcs/burner)
Shaft seal kit (1 set /shaft)
Seal plate gasket ( 1 set / plate )
Mechanical seal (1 set)
Flue gas restricting  ring bricks (1set)
Refractory cement (1 pk ) 
Shaft bearing (1 set)
V belts (1 set)

conception d'incinérateur d'hôpital

Conception d’incinérateur hospitalier INCINERATEUR DE DECHETS HOSPITALIER

TECHNIQUES DE SPÉCIFICATIONS.
Capacité destructive de 55 Kg / h jour de déchets hospitaliers avec un p? .C. je jusqu’à 3.200 Kcal / Kg
1) Type de déchet

hospitalier
2) Pouvoir calorifique inférieur 3.200 kcal / kg
3) Humidité 20%
4) Teneur en cendres et / ou inertes 8%
5) Capacité destructive nominale 55 kg / h
6) Volume chambre de combustion 1,65 m3
7) Volume chambre postcombustion 2,1 m3
8) Temps transit des fumées en postcombustion / sec. <2
9) Température minimale en postcombustion 1.100 ° C
10) Teneur d’oxygène libre en postcombustion 6%
11) Attribution refus confectionné en sachets PEHD
12) Dispositif de chargement ?: hydraulique ?; capacité de charge 0,5 m3

13) Gazole combustible prévu
14) Br? Leur en chambre de combustion nbr?: 1
15) Br? Leur en chambre de postcombustion nbr?: 2

CONSTITTUTION DE L’APPAREIL.
1.CHARGEMENT
Système de chargement hydraulique afin de pouvoir charger le four en toute sécurité même durant son fonctionnement et

aussi assurer la puissance destructive globale de 450 kg / j?
Le système comprend ?:
1-1Trémie de chargement de forme parallélépipédique de 0,5 m3 de volume, réalisée en t? Le d’acier, bridés sur la paroi

frontale de la chambre de combustion et munie d’un couvercle à charnières actionné par vérin hydraulique ?.
Dimensions?:
oLongueur 1200 mm
oHauteur 700 mm
oLargeur 600
1-2Un poussoir hydraulique assurera le chargement de la chambre de combustion
1-3 Une porte de chargement de la chambre de combustion constituée d’une guillotine à vérin hydraulique revêtue

de réfractaire
1-4Un central hydraulique pour piloter tous les vérins de commande, comprenant ?: réservoir, pompe, électrovannes et

tuyauteries

2.CHAMBRE DE COMBUSTION PRIMAIRE

2-1- Le bati est une structure métallique cylindrique revêtue intérieurement d’une couche d’isolant et d’une

couche de réfractaire.
2-2-Volume intérieur ?: 1,65 m3
2-3-Aménagement
? portillon de décharge des cendres ?: frontal ?; monté sur double charnière et revêtu de réfractaire avec hublot

inspection
? La connexion à la chambre de chargement est revêtue de réfractaire
? La connexion de la chambre de combustion et de la chambre de post combustion est revêtue de réfractaire
? Installation des bruleurs
? Installation du système de distribution de l’air comburant
? Installation des sondes de mesure de la température
? Le bac de récolte des cendres est en acier au carbone sur roulettes, équipé de racloir métallique permettant

l’évacuation manuelle des cendres
3. BRULEUR DE LA CHAMBRE DE COMBUSQTION
Un bruleur de type à une flamme à l’air soufflé, alimenté par gasoil, équipé des dispositifs de sécurité Puissance

thermique installée 165 KW.
4. COMBURANT À L’AIR
Le système de distribution et dosage de l’air primaire en chambre de combustion comprend ?:
Ventilateur centrifugeuse
? Canalisations de distribution d’air
? Système de distribution d’air à 2 canaux
? Soupape de régulation de l’air motorisé selon les phases de cycle de fonctionnement et de la température

5. CHAMBRE DE POST COMBUSTION
5-1- Chambre de post combustion est installée au dessus du foyer de combustion, elle est constituée d’un

cylindre métallique revêtu intérieurement d’une couche d’isolant et d’une couche de matériaux réfractaires.
5-2- Volume intérieur?: 2,1 m3
Est dimensionnée pour pouvoir garantir un temps de fumée de 2 secondes à 1100 ° C avec un pourcentage d’oxygène libre

d’au moins 6%.
5-3 -Accessoires
Trappe de visite boulonnée frontale pour permettre l’inspection périodique
? La liaison à la chambre de combustion est tapissée de réfractaire
? Installation les br? Leurs
? Installation des sondes de mesure température
6. PRODUCTION DE L’AIR COMBURANT DE LA CHAMBRE DE POST COMBUSTION
Ventilateur centrifugeuse
? Tuyauteries de distribution d’air
? Série de vannes de distribution d’air
? Soupape de régulation de l’air soufflé asservi par la sonde du débit d’oxygène

7. BRULEUR DE LA CHAMBRE DE POST COMBUSTION
Sont prévus 2 br? Leurs du type à l’air soufflé au gasoil équipé des dispositifs de sécurité.
A la mise en route du quatre les deux br? Leurs sont allumés pour assurer la température minimale d’au moins 1100 ° C ?;

ils restent en marche successivement pour maintenir la température constante.
Puissance thermique installée (290 + 350) KW.

8. CHEMINEE D’EVACUATION
Constitué par un conduit métallique vertical de 8 m de long installé au-dessus de la chambre de PC, diamètre 630 mm

en t? le d’acier au carbone avec garnissage intérieur en réfractaire

9. ARMOIRE ELECTRIQUE DE COMMANDE ET REGULATION
Composée de?:
Circuit 380 V- 50 HZ-3 phases
? Voyant sous tension
? Commande d’arrêt général
? Voyant état des bruleurs
? Affichage des températures des deux chambres
? Minuterie des temps des cycles.
? Une variation des vitesses des ventilateurs
? Le tableau et les cablages sont prévus aux règles CEI avec protection IP 55
Microprocesseur pour le contrôle et la régulation des températures, ainsi que les cycles d’opération
? Cablages réalisés selon les règles CEI.

10. INSTRUMENTATION DE CONTROLE ET DE MESURAGE CONTINU
Les dispositifs suivants sont prévus ?:
1) Thermocouples pour la mesure de la température en chambre de combustion? et postcombustion, à la sortie de

l’échangeur dans la section d’entrée du filtre
2) Système de mesure de la concentration d’oxygène dans les fumées humides à la sortie de la chambre de postcombustion

constitué de?:
? Sonde de mesure de l’oxygène à l’oxyde de zirconium
? Pompe à la membrane
? débitmètre