Blog

burning 150 kg of waste incinerator

In an attempt to make a temporary relief in the mounting waste disposal issues, a new incinerator will begin functioning at the Kozhikode Medical College soon.

The incinerator was installed with the finance in the Hospital Development Society (HDS).

HDS member Saleem Madavoor advised’City Express’ that the society has allotted’15 lakh towards the expenses that will be obtained for the installation functions.

An official of this medical school said that an expert group, deputed from SIDCO, has seen the medical school to reassess the primary arrangements.

The work order was awarded to SIDCO and an agreement was signed between the medical college government and SIDCO officials three weeks ago.

The medical school official added that the functions of this incinerator are finished and installation functions will start within few days.  If the new incinerator begins working, the waste disposal problems will be partly addressed. The incinerator which has a capacity of burning 150 kg of waste, will eliminate the residue generated from the medical college hospital.

Meanwhile, the medical school will continue to grapple with the waste being produced in the Institute of Maternal and Child Health (IMCH) and Super Specialty block because the incinerator for those blocks, which have been suggested at a price of’63.5 lakh from the state authorities still remains on papers. If the incinerator becomes a reality around 5,000 kg of waste could be disposed everyday.

advice from: http://www.newindianexpress.com/states/kerala/Waste-Woes-Medical-College-Gets-Partial-Relief/2015/07/17/article2924500.ece

INCINERATOR QUESTIONNAIRE

1. Type of waste: Trash  
2. Any other type:
3. Quantity of waste generated per day in kg: (50 Ton per day) SOW
4. Duration – incinerator will be used per day: (Minimum 12 hours) SOW
5. Approximate moisture content: 
6. Local incinerator operating and emission standards: US-EPA 
7. What is the height of the chimney required: Not known
8. Fuel proposed to be used: Deiseal Oil 
9. Availability of power and type: 220 or 110 
10. Details of space available: Plenty of space 
11. Do you require an automatic loading system: [**] Yes  [**] No 
12. Do you require a gas scrubbing system: [**] Yes  [ ] No 
13. How soon do you require the system to be delivered: 30 
14. Any other specific requirements:
15. Nature: (Solid/Semi-solid/Liquid)
Burning Capacity: 125 kg minimum/time (3-6times/day), double chamber, double combustion system
Imputing door Mouth Width (mm): 760*760 (approx.)
Chimney External Diameter (mm): 300 ± 10
Combustion Improver Device: 0.11kw, Fuel consumption: 7kg/ hour (max)
Re-Burning Device: Oil consumption: 5kg/h, 0.37kw, Oil consumption: 10-20kg/h
Voltage: 380v/220v AC, Warranty: 1 Year, 50 Hz 

incinérateurs de gros animaux

L’incinérateur doit également être équipé de dispositifs et de mécanismes de chargement spéciaux permettant une incinération sûre des

déchets solides en même temps que les boues liquides. Le chargement des déchets solides peut être réalisé à travers des sacs.

Tous les tuyaux intermédiaires, soufflets et autres raccords pour la connexion entre les réservoirs

, le brûleur, le compresseur et les autres équipements fournis sur la palette doivent être fournis par le soumissionnaire retenu. Le soumissionnaire doit

indiquer les points de raccordement pour les boues, l’OD et l’eau chaude. Les tuyauteries jusqu’à ces points de connexion seront à la charge de

la CEB. Tous les équipements, tels que les pompes, les ventilateurs, les compresseurs, etc. faisant partie du lot d’incinérateur doivent prendre

leur alimentation électrique à partir d’un panneau électrique. Le panneau doit être équipé de disjoncteurs appropriés

et des contacteurs pour chaque composant et doivent permettre le cadenassage indépendant de l’équipement par les opérateurs sans

intervenant de l’intérieur du panneau. Tous les travaux de cadenassage doivent être effectués depuis l’extérieur du panneau électrique. le

Le panneau électrique doit être alimenté par une alimentation triphasée externe.

2.4 Panneau électrique

La tension nominale du panneau doit être de 415 Vca et sa tension d’isolation nominale doit être de 1000 Vca.

– Le compartiment principal doit être alimenté par un tableau existant

Le panneau doit être assemblé en usine, revêtu de métal et de type débrochable pour une application extérieure.

Newsletter – medical waste

Google
medical waste

Medical Waste Incinerators ⋅ 2019年9月23日
www.imcha.net

The worldwide Medical Waste Containers Market 2019 report is expansive research reliant on Medical Waste Containers, which inspects the raised …
Facebook Twitter 标记为不相关

This “Global Medical Waste Management Market” Market report 2019-2024 gives an essential market direction and progressed logical data about …
Facebook Twitter 标记为不相关

Dataintelo, has recently developed a report on the ‘Medical Waste Container market’ which presents substantial inputs about the market size, market …
Facebook Twitter 标记为不相关

Containers which are used in biomedical waste disposal and other medical waste disposal are termed as sharps containers. These are designed to …
Facebook Twitter 标记为不相关

Los Angeles, United State, September 23, 2019,- Global Rubber Shredders Market report is a professional and in-depth study on the market overview, …
Facebook Twitter 标记为不相关

“Because either they’ve got no medical waste bin, or purely because they want to get rid of some rubbish, and it’s been put into the coffin with the …
Facebook Twitter 标记为不相关

… Rs 1,38,500 from meat sellers for dumping waste in open, Rs 1,69,000 for improper disposal of medical waste, and Rs 6,91,000 from garage owners …
Facebook Twitter 标记为不相关
查看更多结果 | Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification)
Newsletter。

|
RSS 以RSS Feed的形式接收此快讯

发送反馈

Medical waste incinerators bio Capacity incinerator medical waste to high combustion temperature

Medical waste incinerator bio Capacity incinerator medical waste to high combustion temperature 
With a smokeless device to protect the environment and with two combustion chambers equipped with gas burners or oil 
-incinerator to burn large volume pieces of 70 cm 
deviation: Automatic Control System 
-destructive capacity from 20 to 30 kgs 
First-room / Temperature = 900 ° C combustion 
2nd bedroom / Temperature = 1200 ° c afterburner 
-burner = 116Kw
Burning Rate: 50Kg/Hr
Feed Capacity: 150Kgs
 Primary Combustion Chamber: 900 Litres
Secondary Combustion Chamber: 300 Litres
Mix Combustion Chamber: Yes
Smoke Filter Chamber: Yes
Feed Mode: Manual
Power: 0.7kW
Fuel Type: Diesel/LPG/Natural Gas
Internal Dimension: 120 x 90 x 85cm (Primary Chamber)
External Dimensions: 200 x 160 x 310cm (Without Chimney)
Burning Efficiency: >98%

brûleur animal

L’usine d’incinération comprendra un tableau de contrôle pour son traitement. Sur le panneau de contrôle, nous aurons une esthétique

affichage des niveaux de température de la chambre. Cet écran esthétique a besoin de garder un œil et de manipuler le brûleur en plus de ses performances.

La capacité de destruction en poids sera de 60 Kg / h.

Il doit pouvoir fonctionner très peu moins de 10 heures / jour

Ce brûleur doit avoir la capacité de détruire tous les déchets inflammables créés par les centres de santé, les installations personnelles, le laboratoire,

instituts, etc.

Spécifications de conception: types A, B, C, D, en plus de E de déchets médicaux

Fourniture, configuration et & & & criblage des SYSTÈMES DE FENTE EN CANAL dans le magasin de déchets avec une capacité suffisante pour garder le système interne

température à 14 degrés Celsius en saison estivale en plus du temps froid

Мусоросжигательный завод Hiclover

описание продукта

Компания Nanjing Clover Medical Technology Co., Ltd. является ведущим производителем мусоросжигательных установок в Китае. Мы – местный производитель и один из крупнейших экспортеров Китая. Техническое оборудование пиролитических инсинераторов является основной обработкой отходов во всем мире, для медицинских отходов, для использованных медицинских отходов в Италии, для использованных мобильных установок для сжигания масла, для использованного кремационного оборудования для домашних животных, цены для использованных инсинераторов для домашних животных, для использованных инсинераторов для домашних животных, использует отходы больничных инсинераторов, для сжигания животных, Кремация домашних животных и др. Solid wste. Емкость от 10кг / час. До 500 кг / час, до 6 тонн в день. В настоящее время мы поставляем различные серии в соответствии с требованиями местных клиентов и проектируем обновленную мусоросжигательную печь с использованием наших передовых технологий. Обновленные конструктивные особенности нашего ассортимента мусоросжигательных печей делают их одними из самых экономичных в мире.

Инсинератор с ПЛК модели TS – это новейшая разработка для обработки отходов, включая медицинские отходы, кремацию животных и другие твердые отходы. Это качественное конструктивное оборудование для различных объектов, таких как больница, экологический отдел, агентства по кремации животных и т. Д. CLOVER Incinerator поставляет обновленные модели с двойной камерой сгорания и камерой дымового фильтра с огнеупорными линиями и температурой камеры сгорания до 1200 ° C.

Предметы / Модель TS10 (ПЛК) TS20 (ПЛК) TS30 (ПЛК) TS50 (ПЛК) TS100 (ПЛК)
Скорость сжигания 10 кг / час 20 кг / час 30 кг / час 50 кг / час 100 кг / час
Емкость подачи 20кг 40кг 60кг 100кг 200 кг
Режим управления ПЛК ПЛК ПЛК ПЛК ПЛК
Камера сгорания 100л 210л 330 л 560 л 1200L
Внутренние размеры 50x50x40 см 65x65x50 см 75x75x60 см 100x80x70 см 120x100x100 см
Вторичная камера 50 л 110л 180л 280L 600 л
Камера дымового фильтра да да да да да
Режим подачи Руководство по эксплуатации Руководство по эксплуатации Руководство по эксплуатации Руководство по эксплуатации Руководство по эксплуатации
Напряжение 220В 220В 220В 220В 220В
Мощность 0,5 кВт 0,5 кВт 0,5 кВт 0,7 кВт 0,7 кВт
Расход масла (кг / час) 5,4–12,6 7,8–16,3 10,2–20 12.1–24 14–28
Расход газа (м3 / час) 6,2–11,4 8–15,7 9,8–20 9,9–26,1 10–32,2
Монитор температуры да да да да да
Температурная защита да да да да да
Масляный бак 100л 100л 100л 100л 200л
Дверца подачи 30×30 см 45×40см 55×50см 70×55см 80×60 см
Камин 3 метра 3 метра 5 метров 5 метров 10 метров
Тип дымохода Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь
Время проживания 2.0 сек. 2.0 сек. 2.0 сек. 2.0 сек. 2.0 сек.
Вес брутто 1500 кг 2200кг 3000кг 4500кг 6000кг
Внешние размеры 140x90x120 см 160x110x130 см 175x120x140 см 230x130x155 см 260x150x180 см

Design standard Multiple chamber incinerator

Waste type organics domestical  waste
Calorific value of waste 9,25 MJ/kg
Ash content 20.80 %
Density 291 Kg/m3
Waste quantity (kg per hr) 12,500
Total Heat input (Gcal/hr) 23.71
organics domestical  waste Solid Domestic waste, after separating the recyclable, such as: plastic, cloth, metal, paper, wood, glass, stones, etc. than larger 10 cms
Design standard Multiple chamber incinerator to the design of EPA  standards, Air pollution control
Description of the Chimney Top mounted, self supporting
Incinerator performance 150kg/hr
Refuse  Hospital waste and carcasses
Recommended Temperatures Minimum 1000⁰C
Dimensions:
Length 
Width 
Height 
Extra width for burners At least 3000mm
Loading door opening Minimum 700mm x 600mm
Hearth area 5.00square meters
Description or grate/hearth A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume At least 3 cubic meters
Mixing chamber volume At least 1 cubic meters
Settling chamber volume At least 3 cubic meters
Weight excluding chimney 15, 000kg at manufacture
Firing tools supplied Hoe, Poker and rake

Precio del incinerador

Descripción del producto

Clover suministra incineradores de desechos médicos, crematorios para mascotas y animales, y otros incineradores de desechos sólidos a más de 30 países. Hemos rediseñado la configuración del revestimiento de los incineradores. También hemos diseñado e instalado nuestro propio sistema informático PLC en el sistema operativo del incinerador. Clover sabe que es importante construirlos mejor, mantenerlo simple y ofrecer un excelente servicio. Hacemos productos de calidad que brindan una excelente recuperación de la inversión, nuestros incineradores son los más robustos y los incineradores médicos de desechos, los incineradores de desechos médicos, los quemadores de aceite usado, los quemadores de aceite usado, los incineradores de aceites usados de China, los incineradores de desechos de aceite en industria.

Las líneas de incineración tienen escala pequeña a gran escala, hasta 500 kg por hora. La cámara de combustión utiliza material de alta resistencia, costoso pero de mejor calidad que la competencia. El sistema de operación del incinerador utiliza el modo de control del programa PLC, renuncia a la complicada operación manual.
Gracias por el apoyo,

incinérateurs de petite capacité

1 Conception de base de l’installation Une installation approuvée doit avoir quatre sections distinctes qui démontrent que trois principes de turbulence, de temps de séjour et de température sont intégrés dans la conception de l’installation. Les sections réglementées peuvent inclure, mais sans s’y limiter:

Disposition générale de l’usine.
Chambre d’alimentation / chargement
Chambre de combustion primaire.
Chambre de combustion secondaire.
Épurateurs de particules
Épurateurs de gaz acides
La cheminée / cheminée.
2 Alimentation et chargement Des méthodes d’alimentation hygiéniques, mécaniques ou automatiques contrôlées doivent être utilisées qui n’influenceront pas négativement la température de l’air dans les chambres primaire et secondaire de l’incinérateur.

Aucun déchet ne doit être introduit dans l’incinérateur:

1. Jusqu’à ce que les températures minimales soient atteintes.
2. Si les températures minimales de combustion ne sont pas maintenues.
3. Chaque fois que la charge précédente n’a pas été complètement brûlée dans le cas de l’alimentation par lots.

4. Jusqu’à ce que l’ajout de déchets supplémentaires ne fasse pas dépasser les paramètres de conception de l’incinérateur.

3 Chambre de combustion primaire La chambre de combustion primaire doit:

1. Être accepté comme zone de combustion primaire.
2. Être équipé d’un brûleur brûlant du gaz / combustible ou des combustibles liquides à faible teneur en soufre. Les autres méthodes de combustion seront jugées au mérite.

3. S’assurer que l’alimentation en air primaire est contrôlée efficacement
4. Assurez-vous que la température de sortie minimale n’est pas inférieure à 850 ° C

4 Chambre de combustion secondaire (post-combustion). La chambre de combustion secondaire doit:

1. Être accepté comme zone de combustion secondaire.
2. Être équipé de brûleur (s) secondaire (s) brûlant du gaz ou du combustible liquide à faible teneur en soufre ou tout autre combustible approprié.

3. Assurez-vous que l’alimentation en air secondaire est contrôlée efficacement.
4. Assurez-vous que le contact de la flamme avec tous les gaz est obtenu.
5. Assurez-vous que le temps de séjour n’est pas inférieur à deux (2) secondes.
6. Assurez-vous que la température du gaz, mesurée contre la paroi intérieure de la chambre secondaire et non dans la zone de flamme, n’est pas inférieure à 1100 ° C.

7. Assurez-vous que la teneur en oxygène des gaz émis n’est pas inférieure à 11%.
8. Assurez-vous que les températures primaire et de combustion sont maintenues jusqu’à ce que tous les déchets aient complètement brûlé.

5 Suppresseurs de particules Un collecteur de particules mécanique doit être incorporé après la chambre de combustion secondaire pour éliminer les particules polluantes entraînées dans le flux de gaz de combustion. Les collecteurs de particules peuvent comprendre l’un quelconque des éléments suivants ou une combinaison de ceux-ci:

Séparateur cyclone
Précipitateurs électrostatiques
Filtres en tissu
6 Cheminée / cheminée 1. La cheminée doit avoir une hauteur minimale de 10 mètres au-dessus du niveau du sol et dégager le point le plus élevé du bâtiment d’au moins 3 mètres pour tous les toits. La topographie et la hauteur des bâtiments adjacents dans un rayon de 50 mètres doivent être prises en compte.

2. Si possible, la cheminée doit être visible pour l’opérateur depuis la zone d’alimentation.
3. L’ajout d’air de dilution après la combustion pour satisfaire aux exigences de ces directives est inacceptable.

4. La vitesse de sortie minimale doit être de 10 m / s et au moins deux fois la vitesse du vent environnant (vitesse d’efflux = vitesse du vent x 2), la valeur la plus élevée étant retenue pour garantir l’absence de lessivage des gaz sortants.

5. Un point de mesure des émissions doit être fourni.

7 Instrumentation Un instrument permettant de déterminer la température de la paroi intérieure et non la température de la flamme du brûleur doit être fourni pour les chambres primaires et secondaires.

2. Une alarme sonore et visible doit être installée pour avertir l’opérateur lorsque la température secondaire descend en dessous de la température requise.

3. En plus de ce qui précède, les instruments suivants peuvent également être nécessaires.
Un compteur / enregistreur de monoxyde de carbone et / ou d’oxygène
Un densimètre / enregistreur de fumée
Un débitmètre / enregistreur de gaz
Un compteur / enregistreur de particules solides
Tout autre instrument ou mesure qui peut être considéré comme nécessaire

8 Emplacement / emplacement 1. Doit être situé conformément au plan d’aménagement des autorités municipales locales pertinentes, à la topographie de la zone et être compatible avec les locaux du quartier,

2. Doit être logé dans une pièce convenablement ventilée.

9 Limites d’émission 1. Efficacité de la combustion:

L’efficacité de combustion (CE) doit être d’au moins 99,00%
L’efficacité de la combustion est calculée comme suit;

CE =% CO2 x 100
% CO2 + CO

2. La température de la chambre primaire doit être de 800 ± 50 ° C

3. Le temps de séjour du gaz dans la chambre secondaire doit être d’au moins 1 (une) seconde à 1050 ± 50 ° C, avec 3% d’oxygène dans le gaz de cheminée.

4 L’opacité de la fumée ne doit pas dépasser 20% vue à 50 mètres à l’œil nu
5. Toutes les émissions dans l’air autres que la vapeur ou la vapeur d’eau doivent être inodores et exemptes de brouillard, de fumée et de gouttelettes.

6. L’Autorité peut exiger que le titulaire du certificat fasse effectuer des tests par un établissement accrédité pour déterminer les concentrations à la cheminée et / ou au sol des substances suivantes.

Cadmium et composés sous forme de Cd
Mercure Hg
Thallium Tl

Chrome Cr
Béryllium Be
Arsenic As
Antimoine Sb
Baryum Ba
Plomb plomb
Argent Ag
Cobalt Co
Cuivre Cu
Manganèse Mn
Étain Sn
Vanadium V
Nickel Ni
HCL chlorhydrique
Acide fluorhydrique HF
Dioxyde de soufre S02

7. Une efficacité de destruction et d’élimination (DRE) de 99,99% pour chaque principal constituant organique dangereux (POHC) dans l’alimentation des déchets lorsque:

DRE = [(Win – Wout) / Win] * 100
Où: Win = débit d’alimentation massique du POHC dans le flux de déchets acheminé vers l’incinérateur, et
Wout = taux d’émission massique de POHC dans la cheminée avant le rejet dans l’atmosphère.

8. La concentration moyenne de dioxines et de furanes dans les émissions ne doit pas dépasser 80 ng / m3 de dioxines et furanes totaux si elle est mesurée pendant une période de 6 à 16 heures.

Noter:
Toutes les concentrations de polluants doivent être exprimées à Oo C et 1,013 x 10 5 N / m2, gaz sec et correction d’oxygène de 11%.

La correction d’oxygène est calculée comme suit:

Es = 21 – Os x EM
21 – OM

Où: Es = Concentration d’émission calculée à la concentration standard en pourcentage d’oxygène
EM = concentration d’émission mesurée
Os = concentration d’oxygène standard
OM = concentration d’oxygène mesurée

10 Fonctionnement 1. Les matériaux destinés à l’incinération doivent être d’origine et de composition connues et ne doivent être incinérés que dans un four enregistré pour le type particulier de déchets.

2. Il faut tenir un registre de la quantité, du type et de l’origine des déchets à incinérer.
3. L’incinérateur doit être préchauffé à la température de fonctionnement avant de charger les déchets.
4. L’incinérateur ne doit pas être surchargé.
5. L’incinérateur doit être en bon état de fonctionnement à tout moment et ne doit pas être utilisé en cas de défaillance d’un composant. Tout dysfonctionnement doit être consigné dans un journal de bord et signalé à l’autorité compétente.

6. L’opérateur de l’incinérateur et tout le personnel concerné doivent être formés à la satisfaction de l’autorité de contrôle compétente.

11 Entretien ménager Le site où est construit l’incinérateur doit:

1. Ayez de l’eau courante.
2. Avoir un sol solide.
3. Avoir un éclairage si fonctionnement 24h / 24
4. Avoir la conteneurisation et le stockage des cendres volantes avant l’élimination.

12 Santé et sécurité (équipement de protection) 1. Le personnel chargé de la manipulation des déchets doit être bien formé à la manipulation en toute sécurité des déchets dangereux
2. Le personnel doit être équipé d’un équipement de protection approprié tel qu’un masque à gaz, des tabliers, des bottes en caoutchouc, des casques, des gants, des lunettes.

3. Des panneaux de mise en garde et d’avertissement doivent être fournis.
4. Un équipement de lutte contre l’incendie doit être fourni
5. Il ne devrait y avoir ni fumer ni manger sur le site.