Incinerator model A
Burn Rate 65kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Minimum operating temperature 850 °C, please indicate
One year Spare Parts Package for complete maintainability
10m Hose Pipe, indicate length
I000 Litre Fuel Tank + Pipe System, indicate volume
Additional chimney extension, indicate height
Warranty, indicate no of years
i. The primary combustion chamber shall be accepted as the primary combustion zone;
ii. The minimum combustion temperature of the primary chamber shall not be less than 800 degrees C;
Secondary combustion
The residence time in the secondary chamber shall not be less than 2 seconds;
The gas temperature as measured against the inside wall in the secondary chamber, not in the flame zone, shall not be less than as indicated in Lots 1-7 ;
Both the primary and the secondary temperatures shall be maintained until all the waste has been completely combusted;
Chimney
The chimney shall have a minimum height of 4 meters above ground level;
The minimum exit velocity of the emissions shall not be less than 10 metres/second;
Temperature Warnings
An audible and/or visible alarm to warn the operator when the secondary temperature drops to below the required temperature;
General
Control box can be detached and mounted on separate stand at least 1.5 meters from incinerator at approximately 1.6 meter height;
Lot 2
Item 5 Incinerator model B
Burn Rate 150kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Diesel/LPG/LNG, please indicate
Power Supply for Control Box- 220V-240V 50Hz single phase
Minimum operating temperature 920 °C, please indicate
One year Spare Parts Package for complete maintainability
Item 6 10m Hose Pipe, indicate length
Item 7 I000 Litre Fuel Tank + Pipe System, indicate volume
Item 8 Additional chimney extension, indicate height
Warranty, indicate no of years
Lot 3
Item 9 Incinerator model C
Burn Rate 250kg/h minimum
Weight (kg) please indicate:
Secondary Chamber
Gas Retention Time 2 Seconds
Fuel Diesel/LPG/LNG, please indicate
Power Supply for Control Box 220V-240V 50Hz single phase
Minimum operating temperature 920 °C, please indicate
One year Spare Parts Package for complete maintainability
Item 10 10m Hose Pipe, indicate length
Item 11 I000 Litre Fuel Tank + Pipe System, indicate volume
Item 12 Additional chimney extension, indicate height
Warranty, indicate no of years
Lot 4 – High Temperature Waste Incinerator
Item 13 HTW Incinerator model D
Burn Rate – 150kg/hour minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time 2 Seconds
Fuel Diesel/LPG/LNG, please indicate
Power Supply for Control Box 220V-240V, single phase 50-60Hz
Minimum operating temperature 1200°C, please indicate
One year Spare Parts Package for complete maintainability
Item 14 10m Hose Pipe, indicate length
Item 15 1000 Litre Fuel Tank + Pipe System, indicate volume
Item 16 Additional chimney extension, indicate height
Warranty, indicate no of years
Lot 5 – Mobile Incinerator
2. Incinerator provides 2 chamber incineration and holds gasses for a minimum of 2 seconds.
3. Each incinerator must have adequate labelling for parts/areas of high occupational health and safety risk on the incinerator.
4. Evidence their product meets relevant national or international emissions standards, such as the United States Environmental Protection Agency, United Kingdom Department for Environment Food
& Rural Affairs, or European Union regulations and directives.
Item 17 Mobile Incinerator model E
Burn Rate 50kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Minimum operating temperature 850 °C, please indicate
One year Spare Parts Package for complete maintainability
Item 18 10m Hose Pipe, indicate length
Item 19 1000 Litre Fuel Tank + Pipe System, indicate volume
Item 20 Additional chimney extension, indicate height
Lot 6 – Mobile Incinerator
Item 21 Mobile Incinerator model F
Burn Rate 100kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Minimum operating temperature 850 °C, please indicate
One year Spare Parts Package for complete maintainability
Item 22 10m Hose Pipe, indicate length
Item 23 1000 Litre Fuel Tank + Pipe System, indicate volume
HTW Mobile Incinerator model G
Burn Rate 100kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Minimum operating temperature 1200 °C, please indicate
One year Spare Parts Package for complete maintainability
10m Hose Pipe, indicate length
1000 Litre Fuel Tank + Pipe System, indicate volume
Blog
BRÛLEUR DIESEL, AVEC RÉSERVOIR DE STOCKAGE DE GAZ DE 1000 LTR ET ARBRE FUMÉE 6M
Articles / modèle
TS250 (API)
photo
Idée
Traitement d’incinération des déchets
Prix de gravure
250 kg / heure en moyenne
Capacité d’alimentation
Critère 400kg / alimentation
Contrôle Etablissement
PLC (brûleur de contrôleur de raisonnement programmable)
Chambre de combustion
2000 L
Mesures intérieures
210 x 88 x 110 cm
Deuxième chambre
1000 L
Chambre de filtre à fumée
Oui
Réglage de l’alimentation
Guide
Tension
220V
Pouvoir
2,0 Kw
Consommation d’huile (kg / heure)
Régulier 24,2 (DO)
Consommation de gaz (m3 / heure)
***
Affichage de la température
Présent numérique
Protection du niveau de température
Oui
Cuve à mazout
1000 L
Porte d’alimentation
2,04 x 1,06 M
Smokeshaft
3 mètres
Type de cheminée
Acier inoxydable
1er.
Poids brut
9 000 kg
Mesures extérieures
3,00 mx1,60 mx3,00 m (sans cheminée)
STRATÉGIE DE RECHANGE DE RECHANGE DE DEUX (2) ANS POUR LE SYSTÈME DE CHAUFFAGE À ÉVACUATION D’HUILE 2 X LINE THING
2 X ENSEMBLE DE RÉPARATION DE BÉTON (25KG)
2 X THERMOCOUPLE
2 X CORDE À FEU (1M)
2 X HT MASTIC (PAR BRÛLEUR)

1 X PPE ENSEMBLE
2020-06-27
2 X CORDE À FEU (1M)
2 X HT MASTIC (PAR INCINÉRATEUR)
1 X PAQUET D’ÉPI

Tél: + 86-25-8461 0201
Site Web: www.hiclover.com
E-mail: [email protected]
E-mail: [email protected]
2020-06-27
Больничная печь для сжигания отходов (TS50 PLC)
описание продукта
Nanjing Clover Medical Technology Co., Ltd. – ведущий производитель мусоросжигательных установок в Китае. Мы – местный производитель и один из крупнейших экспортеров Китая. Техническое оборудование пиролитических инсинераторов – это основная переработка отходов во всем мире, включая медицинские отходы, сжигание животных, кремацию домашних животных и другие твердые отходы. Емкость от 10кг / час. до 500 кг / час, до 6 тонн в день. В настоящее время мы поставляем различные серии в соответствии с требованиями местных клиентов и проектируем обновленную мусоросжигательную печь с использованием наших передовых технологий. Обновленные конструктивные особенности нашего ассортимента мусоросжигательных печей делают их одними из самых экономичных в мире.
Инсинератор с ПЛК модели TS – это новейшая разработка для обработки отходов, включая медицинские отходы, кремацию животных и другие твердые отходы. Это качественное оборудование для китайских производителей кремационного оборудования, китайских производителей медицинских инсинераторов, китайских кладбищ для домашних животных, китайских поставщиков инсинераторов, производителей клиник, таких как больница, экологический отдел, агентства по кремации животных и т. Д. CLOVER Incinerator поставляет обновленные модели с двойная камера сгорания и камера дымового фильтра с огнеупорными линиями, а температура в камере сгорания до 1200 градусов C.
| Предметы / Модель | TS10 (ПЛК) | TS20 (ПЛК) | TS30 (ПЛК) | TS50 (ПЛК) |
| Скорость сжигания | 10 кг / час | 20 кг / час | 30 кг / час | 50 кг / час |
| Емкость подачи | 20кг | 40кг | 60кг | 100кг |
| Режим управления | ПЛК | ПЛК | ПЛК | ПЛК |
| Камера сгорания | 100л | 210л | 330 л | 560 л |
| Внутренние размеры | 50x50x40 см | 65x65x50 см | 75x75x60 см | 100x80x70 см |
| Вторичная камера | 50 л | 110л | 180л | 280L |
| Камера дымового фильтра | да | да | да | да |
| Режим подачи | Руководство по эксплуатации | Руководство по эксплуатации | Руководство по эксплуатации | Руководство по эксплуатации |
| Напряжение | 220В | 220В | 220В | 220В |
| Мощность | 0,5 кВт | 0,5 кВт | 0,5 кВт | 0,7 кВт |
| Расход масла (кг / час) | 5,4–12,6 | 7,8–16,3 | 10,2–20 | 12.1–24 |
| Расход газа (м3 / час) | 6,2–11,4 | 8–15,7 | 9,8–20 | 9,9–26,1 |
| Монитор температуры | да | да | да | да |
| Температурная защита | да | да | да | да |
| Масляный бак | 100л | 100л | 100л | 100л |
| Дверца подачи | 30×30 см | 45×40см | 55×50см | 70×55см |
| Камин | 3 метра | 3 метра | 5 метров | 5 метров |
| Тип дымохода | Нержавеющая сталь | Нержавеющая сталь | Нержавеющая сталь | Нержавеющая сталь |
| 1-й. Температура камеры | 800–1000 градусов | 800–1000 градусов | 800–1000 градусов | 800–1000 градусов |
| 2-й. Температура камеры | 1000-1200 градусов | 1000-1200 градусов | 1000-1200 градусов | 1000-1200 градусов |
| Время проживания | 2.0 сек. | 2.0 сек. | 2.0 сек. | 2.0 сек. |
| Вес брутто | 1500 кг | 2200кг | 3000кг | 4500кг |
| Внешние размеры | 140x90x120 см | 160x110x130 см | 175x120x140 см | 230x130x155 см |
Specifications for Double Chamber Incinerator
INCINERATOR DESCRIPTION
The Model is for up to 300kgs capacity per batch load and will burn at around 55kgs per hour.
The unit has top loading design and has a heavy duty refractory cement lining for maximum heat retention. Unit have large top lid for easy loading, and specially designed front ash door, for ash removal.
This unit operates at over 1100°C in the primary chamber to ensure complete combustion. This model also benefits
from a heavy duty secondary chamber and burner which ensures a complete re-burn of any smoke and emissions and a 0.5 second gas retention time.
Burn rate 150kg/h minimum
Secondary Chamber Yes
Gas Retention Time 2 seconds
Fuel Diesel/LPG/LNG
Power Supply for Control Box 220V-240V 50Hz single phase
Minimum Operating Temperature 920˚C
PRIMARY CHAMBER
Heavy-duty steel casing
High quality refractory lining and insulation
Large full size top load door and liquid retention sill
1 x diesel oil fired ignition burners operated on/off
SECONDARY CHAMBER
Heavy-duty steel casing
High quality refractory lining and insulation
1 x diesel oil fired ignition burners operated on/off
Specifications for Double Chamber Incinerator:
Primary Combustion
The primary combustion chamber shall be accepted as the primary combustion zone.
The minimum combustion temperature of the primary chamber shall not be less than 800 degrees c
Secondary Combustion
The residence time in the secondary chamber shall not be less than 2 seconds
The gas temperature as measured against the inside wall in the secondary chamber ,not in the flame zone shall not be less than as indicated in Lot 1-7
Both the primary and secondary temperatures shall be maintained until all the waste has been completely combusted
Chimney
The chimney shall have a minimum height of 4 metres above ground level
The minimum exit velocity of the emissions shall not be less than 10metres/second
Temperature Warnings
An audible and/or visible alarm to warn the operator when the secondary temperature drops to below the required temperature
General
Control box can be detached and mounted on separate stand of atleast 1.5metres from the incinerator at approximately 1.6 metre height
CE compliant or equivalent for incinerators of this size and model
Drawings and photos for the offered lots
1 year spare parts,fuel tanks and 10metre hose to come standard with every incinerator
Specifications for Mobile Incinerator Units
Trailer mounted mobile incinerator units suitable for the following applications
Medical waste
Domestic waste
Industrial waste
Animal cadavers
CHIMNEY
Heavy-duty stainless steel casing
1.5m length
0.6m refractory lined stack
CONTROL PANEL
Control of 1 burner
Timer control 0- 12 hours
Integral fan timer control
Temperature Monitoring
Thermostatic Control
Automatic Control
Cycle time set up
ANCILLARIES
Operating and maintenance manuals
Spares list
CONTAINERISATION
incinerator fully installed inside of 10 ft ISO certified container
3,5 kwA electricity generator, 1000 litres fuel tank
Incinerator mounted on the silenblock cushion.
Exigences générales d'un brûleur à 3 chambres de combustion de 100 kg / h
| Spécifications générales d’un incinérateur de 100 kg / h | |||
| Non . | La description | Valeur du paramètre | |
| maquette | HICLOVER YD100 | ||
| 1 | Mode de fonctionnement de la machine | Huile + Puissance | Huile + Puissance |
| 2 | Tension | 220V C 3 phases ou 1 phase | 220V 1P |
| 3 | Consommation d’huile (lit / h) | Moyenne 25-32 lit / h / chambre | Moyenne 33 litres / heure / incinérateur total 3 brûleurs |
| 6 | Taux d’incinération | 100 kg / h = 400-600 kg / 8 h | en moyenne 100kgs par heure |
| 7 | Mode d’alimentation | Manuel | Manuel |
| 8 | Taux de combustion primaire | 1000 lit | 1080 litres |
| 9 | Taux de combustion secondaire | 240 lit | 207 Litres |
| dix | Taux de combustion tertiaire | 416 lit | 452 litres |
| 11 | Matériau de la chambre de combustion | Haute température. béton résistant | Haute température. béton résistant |
| 12 | Dimensions internes ( 1ère chambre) | 100 * 100 * 100 cm (l * w * h) = 1000 allumé | 120 * 100 * 90cm (l * w * h) = 1080 allumé |
| 13 | Dimensions internes (2 ème chambre) | 40 * 40 * 150 cm = 240 éclairés | Diamètre 42 * 150cm = 207 litres |
| 14 | Dimensions internes (3 ème chambre) | 40 * 40 * 260 cm = 416 éclairé | Diamètre 60 * 160cm = 452 litres |
| 15 | Dimensions extérieures | 300 * 155 * 200 cm (l * l * h) | 220 * 160 * 370 cm (l * l * h) |
| 16 | Ouverture de porte | 90 * 90 centimètres | 90 * 90 centimètres |
| 17 | Ventilateur d’air supplémentaire | 1 ventilateur (sur la porte) | 1 ventilateur (sur la porte) |
| 18 | Type de carburant | Diesel/ | Diesel |
| 19 | Brûleur | Marque: Radiateur ou Hofmat | Italie Baltur |
| 20 | Longueur de la cheminée | 3-4 mètres | 5 mètres |
| 21 | Type et matériau de la cheminée | Acier inoxydable de type H ou haute température. béton résistant | 1 mètre haute température. béton résistant +4 mètres en acier inoxydable |
| 22 | Filtre de fumée et d’odeur | Oui, deux étapes. | Épurateur à sec 2 étapes |
| 23 | Moniteur de température | Oui, (pour le 1 er et 3 e chambres) | Oui, (les 3 chambres) |
| 24 | Contrôle de la température | Optionnel | Oui |
| 25 | Cuve à mazout | 500 litre nécessaires. | Oui |
| 26 | Efficacité de combustion | > 98% | Oui |
| 27 | 1ère température de la chambre | 300 à 700 o C | 800 à 1000 o C |
| 28 | 2 ème température de la chambre | 500 à 1000 o C | 1 000 à 1 200 o C |
| 29 | 3 ème température de la chambre | 800 à 1200 o C | 1000 à 1300 o C |
| 30 | Temps de résidence de la fumée | > 2 sec. | > 2 sec. |
| 31 | Poids brut | 5-8 tonnes | moyenne 6,5 tonnes |
| 32 | Nombre de brûleurs | 3 | 3 |

Tél: + 86-25-8461 0201
Site Web: www.hiclover.com
E-mail: [email protected]
E-mail: [email protected]
2020-06-27
Newsletter – waste incinerator
| waste incinerator | |||||||
| www.imcha.net | |||||||
NJ almost passed an eco-friendly food waste bill. Then Trenton happened
NJ almost passed an eco-friendly food waste bill. Then Trenton ….. “Do they want a recycling bill or do they want an incinerator and landfill bill?
|
|||||||
|
Viridor incinerator under investigation by Environment Agency
The incinerator was built on Beddington Lane for Viridor to service a contract from the South London Waste Partnership – made up of Croydon, Sutton, …
|
|||||||
|
Medical Waste Incinerators Market to Witness Comprehensive Growth by 2024
Medical Waste Incinerators Market: Overview. Medical waste incinerator is mainly used for burning wastes produced by medical research facilities, …
|
|||||||
|
South Wales Echo letters: Friday, August 30, 2019
If the incinerator in Cardiff Bay is not enough, they now propose building an incinerator at Corporate Park, Wentloog, near Trowbridge. As a result …
|
|||||||
|
Medical Waste Incinerators Market : Drivers, Restraints, Opportunities, and Threats (2019-2025)
The ‘ Medical Waste Incinerators market’ study Added by Market Study Report provides an in-depth analysis pertaining to potential drivers fueling this …
Global Medical Waste Incinerators Market 2019 – Elastec , Strebl Energy Pte Ltd, Dan Daniel, TTM … – Investor Opinion
|
|||||||
|
Medical Waste Management Market 2019 Dynamics | Industry Growth, New Technologies, Industry …
“Medical Waste Management Market” report presents information of … Incineration segment is estimated to rule the medical waste management …
|
|||||||
|
Production Volume of Incinerator Equipment Market with Expenditures, Company Profiles and …
Global Incinerator Equipment Market industry offers an in-depth scenario which is bifurcate according to manufacturers, Incinerator Equipment product …
|
|||||||
|
Global Incinerator Equipment Market Volume Analysis, Segments and Key Trends 2019-2028
The Global Incinerator Equipment Market report scrutinizes the market status … Others (Furnace, Waste gas flare, Catalytic combustion, Moving grate …
|
|||||||
|
Global Incinerators Market 2019 – ACS, Inc. , INCINERATOR INTERNATIONAL, INC. , Vikas …
The Global Incinerators 2019 2019 report delivers a comprehensive and … EEW Energy from Waste , Gershman, Brickner & Bratton , Martin , Novo E …
|
|||||||
| 查看更多结果 | Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification) | |||||||
| Newsletter。 |
以RSS Feed的形式接收此快讯 |
|
发送反馈
|
Incinerador médico
Información básica.
Información adicional.
Descripción del producto
P: ¿Qué tipo de residuos se pueden utilizar en este equipo?
R: Este equipo para desechos médicos, animales de compañía, desechos municipales, desechos vivos. Prohibir cualquier material explosivo y radiactivo, desechos líquidos y desechos gaseosos.
Q: Estándar de humo del incinerador
A: Estándar del gobierno de China: No. GB18484-2001.
Q: capacidad de tratamiento
A: Capacidad media calculada por residuo médico (menor poder calorífico (LC P): 3.0TH Kcal / Kg por hora), no significa ningún material de desecho. La tasa de combustión animal / mascota es de alrededor de 2/3 de la capacidad promedio.
Tiempo de uso del incinerador de trébol por día hasta 24 horas. Entre cada tiempo de alimentación / combustión, hay alrededor de 0,5 a 1 horas de tiempo de enfriamiento y tiempo para alimentar los desechos. Quema del fabricante del incenrador, quema de desechos médicos, quema de la cámara de desechos, compre un crematorio portátil, compre un incinerador pequeño, compre sistemas de cremación de animales, el tiempo real de combustión por día es de alrededor de 16 horas. La vida útil del incinerador es de 5 a 10 años según el uso.
Generalmente, proponemos laboratorios pequeños, capacidad de uso de clínicas pequeñas por debajo de 20 kg por hora. Cuando se usa el incinerador en el hospital, calcule la capacidad de producción de desechos en alrededor de 2 kg por persona por día. Si hay 200 lechos de enfermo en el hospital, eso significa que necesita una capacidad de incinerador de alrededor de 400 kg por día, el cambio a la capacidad por hora es de alrededor de 30-40 kg por hora. Según el tiempo de operación por día, material de desecho, presupuesto, desarrollo, etc., puede utilizar una capacidad de incinerador de 30 a 50 kg por hora.
* Cómo calcular la tasa de quemaduras por cremación de animales: 2/3 de los desechos médicos.
Q: Montaje y prueba
R: Suministramos todos los documentos e incineradores de fácil instalación y funcionamiento. El cliente puede enviar personas a nuestra fábrica para aprender a instalar y operar. Generalmente, no enviamos al ingeniero al sitio local si no lo solicitamos. El costo de envío es adicional según pedido.
Q: temperatura de combustión
R: La primera cámara de combustión: 800-1000 grados centígrados.
La segunda cámara de combustión: 1000-1200 grados centígrados.
Q: Modo de control del incinerador
R: El modo de control predeterminado es un caso de control común. Modo PLC según modelo y pedido.
P: Costos de operación y mantenimiento
A: Costo de operación según tasa de consumo de combustible y energía / personal, etc.
Anual alrededor de $ 500- $ 1000 USD por año de mantenimiento según modelo, situación de uso.
Una persona puede dar servicio a 02 incineradores unitarios. El personal debe tener conocimientos básicos de electricista para operar / inspeccionar / mantener el incinerador / quemador / soplador de acuerdo con la guía del usuario de operación, y conocer el riesgo de desechos médicos para proteger al trabajador con el elemento de protección necesario.
P: El tiempo de residencia en la cámara de combustión secundaria.
A: 02 seg.
| Artículos / Modelo | YD-10C | YD-20C | YD-30C | YD-50C |
| Tasa de combustión (kg / hora) | 10 kg / hora | 20 kgs / Hr. | 30 kg / hora | 50 kgs / Hr. |
| Capacidad de alimentación (kgs) | 40 kilogramos | 40 kilogramos | 50 kilogramos | 80 kilogramos |
| Peso del equipo | 1200 kilogramos | 1200 kilogramos | 1800 kilogramos | 2200 kilogramos |
| Cámara primaria (litros) | 200 | 200 | 250 | 400 |
| Cámara secundaria (litros) | 140 | 140 | 140 | 140 |
| Dimensiones externas (cm) | 170 x 140 x 160 | 170 x 140 x 160 | 170x140x190 | 180x160x200 |
| Dimensiones internas (cm) | 55x55x65 | 55x55x65 | 55x55x85 | 70x70x85 |
| Tanque de aceite (litros) | 50 | 100 | 100 | 150 |
| Apertura de la puerta (cm) | 38 x 48 | 38 x 48 | 38 x 48 | 45 × 55 |
| Chimenea (M) | 5 | 5 | 5 | 5 |
| Tipo de chimenea | Acero inoxidable | Acero inoxidable | Acero inoxidable | Acero inoxidable |
| Cámara secundaria | SÍ | SÍ | SÍ | SÍ |
| Cámara de mezcla de combustión | SÍ | SÍ | SÍ | SÍ |
| Cámara de filtro de humo | SÍ | SÍ | SÍ | SÍ |
| Combustible de combustión | Gas de petróleo | Gas de petróleo | Gas de petróleo | Gas de petróleo |
| Tiempo de residencia | 2,0 seg. | 2,0 seg. | 2,0 seg. | 2,0 seg. |
| Monitoreo de temperatura | SÍ | SÍ | SÍ | SÍ |
Diesel/LPG/LNG burning primary combustion chamber/primary combustion incinerator
Primary combustion
Diesel/LPG/LNG burning primary combustion chamber/primary combustion zone
Secondary combustion
Residence time in the secondary chamber not less than 2 seconds
Both primary and the secondary temperatures maintained until all the waste has been completely combusted
Chimney
Chimney with a minimum height of 4 meters above ground level
Minimum exit velocity of the emissions not less than 10 metres/second
Temperature Warnings
Audible and/or visible alarm to warn the operator when the secondary temperature drops to below the required temperature
General
Control box that can be detached and mounted on separate stand at least 1.5 meters from incinerator at approximately 1.6 meter
heightItem 1
Incinerator model A
Burn Rate 65kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Minimum operating temperature 850 °C, please indicate
One year Spare Parts Package for complete maintainability
10m Hose Pipe, indicate length
I000 Litre Fuel Tank + Pipe System, indicate volume
Additional chimney extension, indicate height
Warranty, indicate no of years
Item 2
Incinerator model B
Burn Rate 150kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Diesel/LPG/LNG, please indicate
Power Supply for Control Box- 220V-240V 50Hz single phase
Minimum operating temperature 920 °C, please indicate
One year Spare Parts Package for complete maintainability
10m Hose Pipe, indicate length
I000 Litre Fuel Tank + Pipe System, indicate volume
Additional chimney extension, indicate height
Warranty, indicate no of years
Item 3
Incinerator model C
Burn Rate 250kg/h minimum
Weight (kg) please indicate:
Secondary Chamber
Gas Retention Time 2 Seconds
Fuel Diesel/LPG/LNG, please indicate
Power Supply for Control Box 220V-240V 50Hz single phase
Minimum operating temperature 920 °C, please indicate
One year Spare Parts Package for complete maintainability
10m Hose Pipe, indicate length
I000 Litre Fuel Tank + Pipe System, indicate volume
Additional chimney extension, indicate height
Warranty, indicate no of years
High Temperature Waste Incinerator
Capacity at least (4000) kg/day ((Day=16 Working Hours))
Capacity at least (4000) kg/day ((Day=24 Working Hours))
With the following features:
*Automatic feeder as original part of the unit.
*Automatic ash / leftovers removal as original part of the unit.
*Water Injection System to control the temperature>
*Flue gas filtration system complying with EU.
*Continuous emission monitoring and recording system.
*It should include installation, testing, and staff training.
*6 nos. of heavy duty loading containers.
Item 4
HTW Incinerator model D
Burn Rate – 150kg/hour minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time 2 Seconds
Fuel Diesel/LPG/LNG, please indicate
Power Supply for Control Box 220V-240V, single phase 50-60Hz
Minimum operating temperature 1200°C, please indicate
One year Spare Parts Package for complete maintainability
10m Hose Pipe, indicate length
1000 Litre Fuel Tank + Pipe System, indicate volume
Additional chimney extension, indicate height
Mobile Incinerator
Item 5
Mobile Incinerator model E
Burn Rate 50kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Minimum operating temperature 850 °C, please indicate
One year Spare Parts Package for complete maintainability
Mobile Incinerator
Item 6
Mobile Incinerator model F
Burn Rate 100kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Minimum operating temperature 850 °C, please indicate
One year Spare Parts Package for complete maintainability
10m Hose Pipe, indicate length
1000 Litre Fuel Tank + Pipe System, indicate volume
Additional chimney extension, indicate height
Warranty, indicate no of years
High Temperature Waste Mobile Incinerator
Item 7
HTW Mobile Incinerator model G
Burn Rate 100kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Minimum operating temperature 1200 °C, please indicate
Primary combustion
Diesel/LPG/LNG burning primary combustion chamber/primary combustion zone
Secondary combustion
Residence time in the secondary chamber not less than 2 seconds
Both primary and the secondary temperatures maintained until all the waste has been completely combusted
Chimney
Chimney with a minimum height of 4 meters above ground level
Minimum exit velocity of the emissions not less than 10 metres/second
Temperature Warnings
Audible and/or visible alarm to warn the operator when the secondary temperature drops to below the required temperature
General
Control box that can be detached and mounted on separate stand at least 1.5 meters from incinerator at approximately 1.6 meter
height
Warranty, indicate no of years
incinérateur de laboratoire
la carcasse entière des animaux (bovins, chevaux,
Moutons, porcs, etc.), ainsi que des déchets biologiquement dangereux
Produits dans le poêle à combustible.
? Portes d’ouverture – le système automatisé de fermeture et de fixation,
Qui sont gérés à distance par l’opérateur.
? conçu pour fonctionner en mode long et rapide
Action (Quick Start EP – i)
? Entièrement mobile – monté sur châssis à roues
Même pendant l’opération. Des incinérateurs doivent être fournis
En équipement standard, un camion spécial
rétention d’air pendant au moins 2 secondes à une température inférieure à 850 ° C, la combustion
Afin d’obtenir le bon effet.
? doit être un incinérateur à deux chambres, primaire et secondaire
Poêles à combustible
? Les déchets pour réduire le volume initial
Possibilité de minimiser (environ 5% de cendres stériles
Forme).
Des incinérateurs doivent être installés dans le réservoir de carburant (diesel)
? La capacité minimale de l’incinérateur de carcasses animales
La destruction de 1000 kg / heure. La capacité de l’incinérateur est calculée
8MJ / kg- matière et 60% d’humidité.
? Il doit être possible d’utiliser l’incinérateur +40
Incinérateur de laboratoire C à – 15 0C
Température et 5% – 95% – des conditions d’humidité.
? Contrôleur PLC et panneau de température intégré
Contrôle automatique, un ordinateur de contrôle, qui est stocké
Informations sur la variation de température en fonction du temps et
Images graphiques.
? doit avoir du carburant avec commande automatique et dysfonctionnement
Système de détection.
? la capacité de pré-échauffement, les déchets corporels brûlent et s’éteignent
La cohérence est indépendante des chambres première et secondaire.
? assurant l’incinérateur en électricité, il
Doit être installé sur le générateur.
? nettoyer l’incinérateur doit être des outils simples,
Sans utiliser aucun équipement supplémentaire
Мусоросжигательные заводы на Фиджи
Чёрный дым выходит из труб Мемориального госпиталя колониальной войны в Суве – это обычное явление.
А после недавнего письма редактору Сатиш Накчед, The Fiji Times провела расследование дыма, который создает препятствие для жителей близлежащих улиц Вайману-роуд.
Распространено мнение, что дым – это продукт сжигаемых в больнице частей тела.
Министр здравоохранения и медицинских услуг Джоне Усамате пояснил, что «мусоросжигательная установка в CWM сжигает все медицинские отходы, производимые в больнице».
«Выбор типа отходов, которые следует сжигать, соответствует международным стандартам инфекционного контроля и утилизации медицинских отходов», – сказал г-н Усамате.
Клинические отходы включают кровь, ткани, человеческие органы и другие части тела.
«Сжигание происходит в контролируемой среде, где предметы сжигаются при очень высокой температуре, чтобы убить все микроорганизмы в отходах.
«Мусоросжигательные установки используются в больницах по всему миру и являются выбранным методом утилизации отходов, поскольку они сводят к минимуму шансы распространения болезней и инфекций».
автор: http://www.fijitimes.com/story.aspx?id=334379