Blog

modern medical waste burning machine

we supply medical two chambers incinerator 800 to 1200 degrees. the capacity from 10kgs per hour to moran than 1000kgs per hour. all incinerator pass ISO and CE certificate.

HICLOVER brand incinerator made in chin and use heavy duty refractory firebrick, fix with PLC AUTO control system.

Call on Mobile: +86-138139 31455(WhatsApp)

Nanjing Clover Medical Technology Co.,Ltd.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour 300-400 kg/hour 500-600 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

Prefabricated Incinerator with a concrete base and chain link fence

The incinerator should be portable, very easy to install, allow for re-location, fit in small space with a chimney length of 4m to drive smoke away to safe heights and also cause current flow of fresh air to drive moisture out of the
rubbish such that the bad odour from sanitary pads is removed and the waste is dried automatically. The incinerator should be made of a non-rusting material such as stainless steel of 4mm gauge. It should not require an extra heat source, but use the heat generated from burning of the solid waste
as its major energy source. This incinerator should be capable of raising temperature to its maximum within three minutes and the heat losses kept to the minimum

Average Temperature
Average Temperature; 850 degrees Cent grade (As per Ministry of Health)
Capacity Capacity; 60 Liters, Auto combustion/nonfuel assisted
Destruction rate 30 liters per hour, waste reduction up to 95%volume
Batch Load 5Kgs per load
Life Span Life span; minimum 10 years

The proposed incinerator units must be complete and include all of the key features listed below and all of the associated support services and interconnections
The forecasted feedstock loads, and daily loading rates are generally summarized as:
• Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values and densities. The wastes will consist of 100% biomedical wastes.
• Wastes either small enough to fit within a 60 litre waste sack or broken up or shredded to less than 300mm in size.

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com
Email: sales
Email: hicloversales

modern medical waste burning machine

we supply medical two chambers incinerator 800 to 1200 degrees. the capacity from 10kgs per hour to moran than 1000kgs per hour. all incinerator pass ISO and CE certificate.

HICLOVER brand incinerator made in chin and use heavy duty refractory firebrick, fix with PLC AUTO control system.

Call on Mobile: +86-138139 31455(WhatsApp)

Nanjing Clover Medical Technology Co.,Ltd.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour 300-400 kg/hour 500-600 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

Prefabricated Incinerator with a concrete base and chain link fence

The incinerator should be portable, very easy to install, allow for re-location, fit in small space with a chimney length of 4m to drive smoke away to safe heights and also cause current flow of fresh air to drive moisture out of the
rubbish such that the bad odour from sanitary pads is removed and the waste is dried automatically. The incinerator should be made of a non-rusting material such as stainless steel of 4mm gauge. It should not require an extra heat source, but use the heat generated from burning of the solid waste
as its major energy source. This incinerator should be capable of raising temperature to its maximum within three minutes and the heat losses kept to the minimum

Average Temperature
Average Temperature; 850 degrees Cent grade (As per Ministry of Health)
Capacity Capacity; 60 Liters, Auto combustion/nonfuel assisted
Destruction rate 30 liters per hour, waste reduction up to 95%volume
Batch Load 5Kgs per load
Life Span Life span; minimum 10 years

The proposed incinerator units must be complete and include all of the key features listed below and all of the associated support services and interconnections
The forecasted feedstock loads, and daily loading rates are generally summarized as:
• Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values and densities. The wastes will consist of 100% biomedical wastes.
• Wastes either small enough to fit within a 60 litre waste sack or broken up or shredded to less than 300mm in size.

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com
Email: sales
Email: hicloversales

photo cell for incinerator burner spare parts

we supply kinds of spare parts for waste incinerator and oil or gas burners.

SENSOR. BTL20/BTL26 BURNER, FLAME DETECTOR, QRB1B L=350
CAPTEUR. BTL20 / BTL26 BRULEUR, DETECTEUR DE FLAMME
Motor  
Control box Simens
Pump coupling oil pump
Photo cells  
Sets ht leads High voltage cable
Sets electrode Ignition electrode
Oil valve Oil pump electromagnetic valve
Nozzle

Nanjing Clover Medical Technology Co.,Ltd.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour 300-400 kg/hour 500-600 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com
Email: sales
Email: hicloversales

inquired medical waste incinerator comprehensive detailed catalogs and data sheets

TS10 PLC Waste Incinerator

Outline Dimension:1.75 x 1.3 x 1.7m
Weight: Ave.1500kgs
Main body(Primary combustion chamber) Material:Carbon Steel Q235B+Stainless Steel 310s+refractory firebrick material(high temperature resistance up to 1750℃) Capacity: 10-20kg/batch Combustion temperature: 800-1000℃ With chamber door, oxygen supplementation wind port, burner port, temperature control and alarm device, etc.
[1 unit ]
Secondary combustion chamber Material:Carbon Steel Q235B+Stainless Steel 310s+refractory firebrick material(high temperature resistance up to 1750℃) Combustion temperature:1000-1200℃ With observation port, burner port, temperature control and alarm device, etc.
[1 unit ]
High temperature flue gas filtration chamber Material: Outside plate: Q235B, Inside acid-resisting, alkali-resisting refractory poured material. With ash door and filtration material.
[1 unit ]
1# BURNER OF 1# CHAMBER Riello brand (Italy) (High quality, combustion-resisting) Fuel: Natural gas
[1 unit ]
2# BURNER OF 2# CHAMBER Riello brand (Italy) (High quality, combustion-resisting) Fuel: Natural gas
[1 unit ]
Chimney Material: Stainless steel,304 Length: 5m ( other length as customer request)
[1 unit ]
Temperature control device -Thermocouple
[2 unit ]
Control valve
[2 pcs ]
Fastening and sealing elements -Bolts, nuts, washers, paper packing etc.
[1 set ]
Control Cabinet Rain proof type Power indicator Voltage: 220V Temperature indicator Overload protector Leakage protection device
[1 set ]

Nanjing Clover Medical Technology Co.,Ltd.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com
Email: sales
Email: hicloversales

pictures of 500kg per hour machine

pictures of 500kg per hour machine

Items/Model TS500(PLC)
Picture

Principle Medical Waste Incineration Treatment

how many burners does the primary have

Burn Rate Average 500 kg/hour,if 500kg has 1 burner
Feed Capacity Average 500kg/feeding
Control Mode PLC(Programmable Logic Controller Incinerator)
Combustion Chamber 2700L
Internal Dimensions 190x120x120cm
Secondary Chamber 1300L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 3.0Kw
Oil Consumption (kg/hour) Average 44(DO)
Gas Consumption (m3/hour) ***
Temperature Monitor Digital Display
Temperature Protection Yes
Oil Tank 400L
Feed Door 90x80cm
Chimney 10Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Gross Weight 15000kg
External Dimensions 400x210x300cm(without chimney)

Nanjing Clover Medical Technology Co.,Ltd.
h. include an operator’s manual (in English and French and Spanish).
i. require minimal preprocessing i.e. there shall be no/very limited need for prior sorting, crushing or shredding.
j. be capable of handling mixed solid waste streams and incinerable hazardous wastes as indicated.
k. can accommodate large variations in waste composition and calorific value.
l. allow for batch loading
m. incorporate an Air Pollution Control System suitable for basic emission control
n. have a thermal efficiency of not less than 85%.
o. primary and secondary chambers shall preferably have rounded inside corners to avoid the formation of dead zones or cold pockets
p. have very low levels of unburned material in the slag
q. include a supplement fuel source and storage unit (e.g., diesel tank),
“r. proposals shall include the fuel consumption at the rated capacity
be CE Certified, meet relevant British, EU or American Standards, or equivalent.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com
Email: sales
Email: hicloversales

pictures of 500kg per hour machine

pictures of 500kg per hour machine

Items/Model TS500(PLC)
Picture

Principle Medical Waste Incineration Treatment

how many burners does the primary have

Burn Rate Average 500 kg/hour,if 500kg has 1 burner
Feed Capacity Average 500kg/feeding
Control Mode PLC(Programmable Logic Controller Incinerator)
Combustion Chamber 2700L
Internal Dimensions 190x120x120cm
Secondary Chamber 1300L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 3.0Kw
Oil Consumption (kg/hour) Average 44(DO)
Gas Consumption (m3/hour) ***
Temperature Monitor Digital Display
Temperature Protection Yes
Oil Tank 400L
Feed Door 90x80cm
Chimney 10Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Gross Weight 15000kg
External Dimensions 400x210x300cm(without chimney)

Nanjing Clover Medical Technology Co.,Ltd.
h. include an operator’s manual (in English and French and Spanish).
i. require minimal preprocessing i.e. there shall be no/very limited need for prior sorting, crushing or shredding.
j. be capable of handling mixed solid waste streams and incinerable hazardous wastes as indicated.
k. can accommodate large variations in waste composition and calorific value.
l. allow for batch loading
m. incorporate an Air Pollution Control System suitable for basic emission control
n. have a thermal efficiency of not less than 85%.
o. primary and secondary chambers shall preferably have rounded inside corners to avoid the formation of dead zones or cold pockets
p. have very low levels of unburned material in the slag
q. include a supplement fuel source and storage unit (e.g., diesel tank),
“r. proposals shall include the fuel consumption at the rated capacity
be CE Certified, meet relevant British, EU or American Standards, or equivalent.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com
Email: sales
Email: hicloversales

incinerator for poultry farm dead checkin 575 kg

incinerator for poultry farm dead checkin 575 kg, HICLOVER YD50 incinerator or TS50

Model

YD-50

Picture

Burning Rate

Average 50 kgs/hour

Feed Capacity

Average 150 kgs/feeding

Primary Combustion Chamber

700 Liters

Secondary Combustion Chamber

300 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.8Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Ave.23.5 kg/hour

Gas Consumption (Natural Gas)

Ave.28.2 m3n/hour

Internal Dimensions

110 x 90 x 70cm(Primary Chamber)

External Dimensions

200 x 170 x 340cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

400 Liters

Door Opening

55 x 55cm

Chimney Length

5.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

5500 kgs

Operation Technical Specifications

Primary Chamber Temperature

800℃–1000℃

Secondary Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Burning Efficiency

>98%

Waste Lower Calorific Power

3000Kcal

Nanjing Clover Medical Technology Co.,Ltd.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com
Email: sales
Email: hicloversales

one set small incinerator to Kenya hospital kirinyaga county

there was one set oil fired incinerator send to Kenya. average capacity 30-50kgs per hour for small hospital.

if you have any requirement, please send technical details such as capacity(kgs/hour or day), diesel oil or natural gas, etc, we will support for best incinerator and price.

Mobile: +86-138139 31455(WhatsApp)

Nanjing Clover Medical Technology Co.,Ltd.

Packing Details Serie No. Part Name Size(CM) Weight(Kgs)
01 Incinerator Mainbody 190*130*190 3500
02 Oil Tank Stand Dia.60*Height 190 20
03 Chimney Dia.25*Length 250 70
04 Chimney Dia.25*Length 250 70
Total 5.5 CMB 3660 Kgs

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com
Email: sales
Email: hicloversales

small biometric incinerator

HICLOVER incinerator exert the advantages and discard the disadvantages of the same kind of equipment at domestic and abroad. It is an unique and international advanced medical waste incineration equipment. The equipment is small size, high efficiency, reasonable process, leading technologies and a high harmless degree, ideal garbage treatment equipment for hospital, laboratory, hotel, station, etc.

Main Characteristics:

1, Using fever of gasifying unites burning technology. It applied to burn various kinds of medical waste, such as syringes, infusion set, disposable dressing, and also small animal, some city waste, like paper, tree leaves.

2, Closed vacuum-wide operation, applicable to treat infectious medical waste and to prevent secondary pollution.

3, Whole design, easy to transfer to different place.

4, Combustion burner from China or Italy.

• Sufficient forced air inflow and airflow and fuel supply controls to ensure an exhaust gas oxygen content range of 6-12% at all times.
• Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm.
• Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm.
• Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints
• An electrically powered fan forced air supply, with the capacity for variation by the operator.
• One or more fuel burners designed to use diesel fuel type 2 (vehicle standard) equipped with a spark igniter.
• A digital thermometer with connected to an electronic datalogger. The thermometer shall be located on the chamber wall away from the fuel burner.
”
A heat exchanger to pre-heat air destined for the primary chamber is not compulsory but recommended.
The combustion air systems and fans shall be designed to ensure high combustion efficiency and avoid a reducing (corrosive) atmosphere, incomplete burnout of the flue gases and related problems. It should also be possible to heat the primary air from 10°C to approximately 145°C, depending on the waste composition and moisture content.
“The incinerator shall be designed and equipped to be installed, commissioned and operated in such a way as to prevent emissions into the air giving rise to significant ground-level air pollution; in particular, exhaust gases shall be discharged in a controlled fashion by means of a stack the height of which is calculated in such a way as to safeguard human health and the environment.

Nanjing Clover Medical Technology Co.,Ltd.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com
Email: sales
Email: hicloversales

L'opérateur de l'incinérateur de déchets de Burnaby poursuivi en justice pour des problèmes de pollution

Le Greater Vancouver Sewerage and Drainage District poursuit Maxxam Analytics International Corp.et Covanta Burnaby Renewable Energy ULC pour avoir prétendument omis de tester correctement les échantillons de cendres volantes de l’installation de valorisation énergétique du district à Burnaby.

Le district a déposé un avis de poursuite civile devant la Cour suprême de la Colombie-Britannique le 16 octobre. Covanta, selon la réclamation, exploite l’usine d’incinération sous contrat avec le district, et l’installation génère des cendres volantes qui doivent être traitées avant de quitter l’usine et testées. une fois par mois pour assurer le respect de la réglementation sur les déchets dangereux.

Les cendres volantes non dangereuses sont prélevées et éliminées à la décharge de Cache Creek, indique la réclamation. Les échantillons analysés par Maxxam à l’été et à l’automne 2012, cependant, sont revenus indiquant des niveaux élevés de cadmium qui dépassaient les niveaux acceptables autorisés pour l’élimination au site d’enfouissement.

Les résultats, affirme le district, «ont remis en question l’efficacité du traitement des cendres volantes» dans l’installation, obligeant le plaignant à engager des coûts en exigeant davantage d’échantillonnage et de tests, en recherchant la cause des niveaux élevés de cadmium et en trouvant une autre élimination. site de cendres volantes en Alberta. Après que le ministère de l’Environnement a frappé le district avec une lettre d’avis de non-conformité, le plaignant a engagé des «consultants, experts et conseillers juridiques» pour l’aider à enquêter.

Un audit du laboratoire de Maxxam a révélé qu’il ne suivait pas les méthodes appropriées, appelées «Procédure de lixiviation des caractéristiques toxiques» et «Méthode 1311 de l’Agence de protection de l’environnement des États-Unis» pour tester les cendres volantes, selon le procès. L’évaluation du ministère de l’Environnement a révélé que les résultats de Maxxam n’étaient pas fiables en raison de procédures de test inappropriées et a révélé que «les protocoles de contrôle et d’assurance qualité de Covanta au WTEF [Waste-to-Energy Facility] n’étaient pas suffisamment développés pour identifier si la lixiviabilité se produisait ou s’il y avait un problème. avec les cendres volantes traitées et / ou le système de traitement », déclare la revendication. En outre, le ministère a constaté que Covanta ne pouvait pas facilement «fournir l’assurance que les cendres volantes traitées répondaient aux exigences en matière de déchets dangereux en vertu du règlement sur les déchets dangereux».

Le district demande des dommages-intérêts pour négligence, fausse déclaration, exécution négligente d’un service et rupture de contrat. Les allégations n’ont pas été prouvées devant le tribunal et les défendeurs n’avaient pas déposé de réponses à la plainte au moment de la presse.

par: http://prod-admin1.glacier.atex.cniweb.net:8080/preview/www/2.2551/2.2759/2.2742/1.1493460#