Incinerate: medical waste and general waste Capacity to burn waste: 400-500kg/hr Fuel: Diesel Fuel Consumption: 10 liters/hr maximum Incineration temperature: 950-1300 degrees centigrade Casing: thick (min 5mm) stainless steel casing and fully insulated to withstand sea humidity Voltage 220/240v or 380/415V Frequency 50Hz Feeding: Automatic Ash/leftovers removal: Automatic Flue gas filtration system: Yes Quantity: Four (4) Type: Pyrolytic Use: For drugs With Chassis to be Mounted in truck/lorry May have a primary and secondary combustion chamber Must have a dilution chamber Capacity: 100 Kgs per hour Power Source: Diesel or Natural Gas or Liquified Natural Gas
Category: blog
system solutions for medical environmental protection
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, […]
Incinerator Ignition by Diesel
1. Petrol: diesel 2. Consumption: 8-10liter/hour 3. Capacity: to cremate (carrion and spoils) 350-400kg/hour 4. Temperature: 900-1350?C 5. Operation temperature: -30~40?C 6. Incinerator weight: 1800-2000 kg 7. Volume: 0.70-0.80m/cube 8. Exterior dimension: 1.4-1.6*1.0-1.15m (L*W) 9. Trial able 10. Incinerator mouth size: 50-60cm (W), 65-75cm (L) Ignition by Diesel Minimum burning temperature 1200 Celsius Burning capacity of 20 Tons per day. Cooling by water Burn Rate 100Kg/h Shipping Weight 4000kg Capacity 300Kg MINIMUM Max. Burn out time 3.0 hrs. Avg. Ash Residue 3% Heavy Duty refracting lining to withstand 15000C Min. Operating Temperature 8500C Max. Operating Temperature 14500C Residency Time in Secondary Chamber 2 sec. Density Insulation (high) 22mm Avg. Fuel Consumption p/hr 7 to 9ltr Fuel Dual, box & Oil/Diesel Temperature Monitoring YES Auto ignition YES Refractory Casting (min.) 65mm Refractory Casting (min) 65mm INCINERATORS Biological waste disposal system (INCINERATOR). Incinerator must meet the following specifications: Combustion Capacity (kW) = 581 ±10% Combustion Capacity (kcal/h) = 500,000±10% Combustion Capacity – Solid waste IMO spec, (kg/h) = 100 IMO spec. (I/charge) Minimum Zero 0 to Maximum = 250 Combustion Capacity – Sludge oil IMO spec, (l/h) (at 20% water content) -66±10% Max. l/h (at approx. 50% water content) = 100 ±10% Weight approx. (kg) = 4,850 ±10%
Containerized Mobile Incinerator
The incinerator mounted in ISO Container before leave factory, free-installation, no incineration house build construction,movable by truck.
About Hiclover Medical Enviromental
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical disposable, biological waste, […]
Medium/Large Scale Waste Incinerators
Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel…
Required Specifications for Mobile Incinerator
Operational Capabilities PROCESS MINIMUM 1 TON PER DAY OPERATED WITH LIMITED TRAINING REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS ABILITY TO BURN WASTE LUBRICANTS (POL) HANDLE ORGANIC SOLIDS (TO INCLUDE RMW) DEPLOYABLE MOBILE 24 HRS OF CONTINUOUS USE AUTOMATIC LOADING SYSTEM AUTOMATED ASH REMOVAL SYSTEM […]
hospital incinerator manufacturers
SECTION V TECHNICAL SPECIFICATIONS OF THE INCINERATOR General Description The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The regulated sections may include but not limited to: Overall plant layout Feed chamber/charging Primary combustion chamber Particulate scrubbers Acid gas The stack/chimney. Minimum […]
hospital incinerator manufacturer
Up to 600kgs per ten-hour day of Type IV pathological waste or red bag waste rated at 2200 BTU’s per kg, based on batch loading twice daily. Incinerator, 20 kg/hr Burn Capacity (min. 1200 kgs. Waste Feed Capacity per day) (4-6 hours operations) (Power Supply 380V, 50Hz, 3Ph) Capacity: 30 kg/hr. Number item: 01 unit […]
laboratory incinerator china manufacturer
Incinerator dual chamber with capacity 1.5 m3/batch or 6 m3/ day, digital thermocontrol range 0‐1200 C, thermocouple, air supply capacity 10m3/ minute, power consumption 1.2kWH/ hour, power 3 phase with netral, cooling water sprinkler capacity 5L/ minute, completed with refractory (insulation, castable, ceramic blanket) and PLC SUPPLY, INSTALLATION AND COMMISSIONING OF WASTE INCINERATOR – TECHNICAL […]