Category: blog

diesel fired incinerator

diesel fired incinerator that can accommodate a batch load of up to 100 kg with a daily burning requirement of up to 500kg per 8 hour day. air pollution regulations in which the dust level should be less 50 mg/m3 with smokeless emissions.Our electrical power supply is 415V, 3 phase, 50 Hz.

Containerised Biohazard Incinerator

BIOHAZARD DISPOSAL: CONTAINER GENERAL INCINERATOR, IDEAL FOR INCINERATION OF VARIOUS TYPES OF WASTE, FULLY CONTAINERISED IN A 20 FT CONTAINER, TO INCLUDE BUILT-IN FUEL TANK AND GENERATOR. mobile Incinerator TECHNICAL SPECIFICATIONS: COMBUSTION CHAMBER VOLUME (M3); 0.54 m3. SUGGESTED BATCH SIZE: 60 KG, BURN RATE: 69 KG PER HOUR, AVERAGE FUEL CONSUMPTION 13 KG PER HOUR, […]

Incinerator for hospital

DESCRIPTION OF WORKS   The services and equipment described in this specification comprises the supply, delivery, installation, testing and commissioning of an incinerator and the associated accessories including oil installation at the Hospital.   The tenderer is to ensure that the equipment they proposes to supply is from a reputable manufacturer with full spare back-up […]

organic and hazardous waste incinerators

Diesel incinerator. 25Kg/h. It will have mainly paper, cardboard and food, though also it will incinerate medical waste. So the incinerator shall be able to handle organic and hazardous waste. Spare parts for one year. The design should prevent any release of polluting substances into soil, surface water and groundwater. Combustion zone has to reach […]

The medical waste incinerator

Electrical safety: The medical waste incinerator shall meet the requirements of IEC 61010-2-040, UL 61010A-2-041, or an equivalent electrical safety standard; as weil as the electromagnetic compatibility requirements under EN 61326:1997 or equivalent standard. Physical: Safety           Belts, pulleys, chains, gears and other rotating parts as well as sharp edges, located where persons come in close […]

Double Combustion Chamber Incinerators

Primary combustion chamber temperature # 850°C with no cold spots Secondary combustion chamber: Shall be constructed with an exterior casing (reinforced to withstand internal pressures without deflection or damage to the refractory or other components) and provided with refractory lining and insulation Secondary combustion chamber temperature 1100°C or higher Secondary combustion chamber residence time # […]

Dual-chamber controlled air incinerator

Materials of construction: The incinerator shall not have any asbestos, asbestos-containing substances, mercury thermometers, and mercury switches. Refractory materials shall be able to meet relevant standards under ISO TC33 and CEN/TC                                                                               187. Types of incinerator design acceptable: Dual-chamber controlled air incinerator or dual- chamber pyrolytic incinerator Waste feed system into the combustion chamber batch or […]

Equipment Double chamber medical infectious waste incinerator

Equipment Double chamber medical infectious waste incinerator Capacity 10-30 kg per hour Characteristics of waste Mainly syringes and needles from immunization routine and campaign activities. However, the following average characteristics are considered*:   heating value above 2000 kcal/kg (8370 kJ/kg); content of combustible matter above 60%; content of non combustible solids below 5%; content of […]