Category: Incinerator

Incinerator Fire flames in primary chamber

The incinerator should be a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner. It should employ a temperature based logic control system to provide optimum control of the operating conditions and incorporate a high capacity thermal oxidizing secondary chamber. It should be designed to retain the exhaust […]

Gasified incineration for burning medical

Fuel type: Natural Gas Burning Capability: – 30-50 kg/time – Daily 3-6 times Medical Waste Incinerators To be used by small hospitals and clinics to safely dispose of infectious and pathological wastes. Load Capacity in the range of up to 200 kg – Burning Rate approx. 50kg/Hour – Incinerators to be very effective, fuel efficient […]

Incinerators and additional equipment

The incinerator shall have chimney, castable high quality refractory lining and incinerator shell, perforated blind for the primary and secondary combustion chambers and air circulation system. The incinerator shall also have the following:- Ash door Primary and secondary burners and fans Temperature indicator devices Electrical wiring from the local isolator FD fan Air receiver Air […]

automating all operations of the incinerator

automating all operations of the incinerator Construction Constructed from heavy duty mild or aluminized steel or equal and approved equivalent Insulation Refractory material lining Combustion Temperatures Above 850 0C, controlled electronically Gas residue or retention time > 2 second at minimum 850 0C Secondary Burner Provided, Diesel fired, Fully automatic, with fuel, temperature and speed […]

TECHNICAL SPECIFICATION FOR DIESEL FIRED INCINERATOR

1.The double chamber incinerator shall preferably be designed. Air supply in the primary and secondary chamber shall be regulated between 30%-80% and 170%-120% of stoichiometric amount respectively. Flow meter/suitable flow measurement device shall be provided on the primary and secondary air ducting. The combustion air shall be supplied through a separate forced draft fan accounting […]

SPECIFICATIONS OF A DIESEL FIRED INCINERATORS

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR 1.0 INCINERATOR, DIESEL, FIRED. Specifications Indicate if item offered complies with each specification. 1.1 General description The incinerator should be a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner. It should employ a temperature based logic control system to provide optimum […]

Incinerator Capacity of destruction in weight: 60Kg/h

1.Capacity of destruction in weight: 60Kg/h 2.It should be able to operate not less than 10 hours/day. 3.This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc.. 4.Design Specification: Types A, B, C, D and E of medical waste 5.“PYROLYTIC” combustion by controlling the gasification of waste. […]

Incinerator Rated Capacity: 100/KG/Hr

Incinerator Rated Capacity: 100/KG/Hr Type of Design: Double Chambered Mode of Heating: Heating Elements Primary Combustion Chamber Waste Charging Door: Provided with refractory lining with sealing gaskets Ash Removed Door: Provided with refractory lining with sealing gaskets Outer Body MOC: Mild Steel, 5mm Primary Chamber: Stainless Steel Operating Temperature :800. ± 50◦C Insulation: Insulation Brick […]

TECHNICAL SPECIFICATIONS FOR NAMAPA HOSPITAL,INCINERATOR 20KG

INCINERATOR 20KG General Specifications 6mm plate steel sheel construction 11cm 1400 º C Refractory L iner Temperature controlled Burners Secondary combustion Burners Interlock Switch on Load Doors Separate Ash Door One Second secondary Residence @ 1000 º C 400 ° C Silicone Based Paint Finish. Alloy Temperature Sensor Factory wired and tested Capacity-20 kg / […]