Category: Uncategorized

300 kg incinerator

i) Patient and operator safety and system performance should not be adversely affected by fluid spills. ii) If the unit is affected, it should fail safely.   c) Overcurrent Protection i) Loss of power to other equipment on the same branch circuit due to internal equipment faults should be prevented by using fuses or circuit […]

3 Combustion Chambers MEDICAL WASTE BURNER

Model WS-35 Image Burning Rate Ordinary 35 kgs/hour Feed Ability Average 80 kgs Main Burning Chamber 460 Litres Secondary Burning Chamber 200 Liters 3rd Burning Chamber 200 Litres Smoke Filter Chamber Damp Scrubber System Feed Setting Handbook Voltage 220V Power 2Kw Fuel Type All-natural Gas/LPG Burner Italy Original Oil Intake (Diesel Oil) *** Gas Consumption […]

china incinerator supplier

f) Alarms i) The unit should have visual or audible alarms to warn operators of any system fault that may cause unsafe or erroneous results. ii) Audible and/or visual indicators should activate when the display reading reaches and remains at the alarm limit. iii) All alarms should be fully explained in the operator’s manual.   […]

Containerized Type Pre-Assembled Mobile Medical Facility Waste Burner Model CA100

Items/Model CA100 Image Concept Medical Waste Incineration Treatment Burn Price Average 100 kg/hour Feed Capability Standard 200kg/feeding Control Mode PLC( Programmable Logic Controller Burner) Burning Chamber 1200L Internal Measurements 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Handbook Voltage 220V Power 1.3 Kw Oil Consumption (kg/hour) Ordinary 20.4 Kgs/Hour Gas Usage (m3/hour) *** […]

ไส้กรองใยแก้วชนิดถุง

2019-05-16 กรอง อากาศ 440 views คุณสมบัติของสินค้า: l    กรอบนอก: กรอบพลาสติก กรอบสังกะสี กรอบอลูมิเนียมอัลลอยด์ หรือกรอบสแตนเลส l    ความหนาของกรอบ: 21, 25, 46, 96 มม. เป็นต้น l    วัสดุกรอง: ใยแก้ว l    อุณหภูมิสูงสุด: 93℃ l    ความชื้นสูงสุด: 99% l    ประสิทธิภาพ: F5, F6, F7, F8 (EN779) การใช้งาน: l    ระบบปรับอากาศและระบายอากาศล่วงหน้าและการกรอง, ผลิตภัณฑ์ เถ้า ภายในระบบเพื่อหลีกเลี่ยงการ ปนเปื้อน l    การกรองล่วงหน้าของเครื่องอัดอากาศขนาดใหญ่, การกรองอากาศกลับของการระบายอากาศแบบรวมศูนย์และระบบปรับอากาศในห้องปลอดเชื้อ, ยืดอายุการใช้งานที่มีประสิทธิภาพสูง […]

Small Medical Waste Incineraotr for COVID-19 Bio Hazardous Medical Waste

HICLOVER – Medical Environmental  Model YD-20 Photo Burning Rate Typical 20 kgs/hour Feed Capability Ordinary 60 kgs/feeding Main Burning Chamber 360 Litres Secondary Burning Chamber 200 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Setting Guidebook Voltage 220V Power 1.0 Kw Gas Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Intake (Diesel […]

small scale medical waste incinerator

Toxic and dangerous wastes, Medical pharmaceutical and hospitable liquids  Wastes Domestic garbage Electric and electronic wastes Industrial wastes In General, all type of wastes and garbages Capacity 50-60Kg/h Combustion supporting materials Coal oil, diesel oil Temperature inside 800-10000C 1000-12000C Burning efficiency >98% Power consumption 1.3KW Noise <78dB Index of let smoke and waste gas Ringelman’s […]

Containerized Mobile Burner Medical Waste Incinerator Model CA50

HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50 Design CA50 Picture Waste Therapy Medical Waste Incineration Treatment Feed Capacity Typical 100 kgs per feeding Burning Rate Average 50 kgs per hr Burning Time per Feed Average 2 hr Control Setting PLC( Programmable Logic Controller Burner) Voltage 220V Power 1.0 Kw Gas Diesel oil Burner […]

Medical Waste Burner for Coronavirus Condition

Coronavirus Disease 2019 (COVID-19) pandemic continues all over the world, clinics,hospitals,goverment may need to consider on-site disposal for the infectious  medical waste. The medical waste incinerators that has been effectively used to dispose of hazardous waste during  viral outbreaks like Ebola. HICLOVER.COM reaches temperatures of up to 1200oC and is able to destroy health care […]

animal crematory equipment

ii) The visual alarm must be specific to the problem and remain on until the alarm condition is corrected; it should not be possible to turn off the visual alarm.   i) Construction Quality i) The unit should have no sharp edges. ii) All external components should be securely mounted. iii) The unit should be […]