Containerized Mobile Incinerator(CA Model)
HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.
Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total
mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce.
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.
Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: sales@hiclover.com
Email: hicloversales@gmail.com
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate (Average) | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity(Average) | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ |
2nd. Chamber Temperature | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
The process of incineration provides the advantage of volume reduction as well as the ability to dispose of recognizable
waste and sharps. On site incinerators provide a quick and easy way of disposing medical waste. This is the most widely
accepted and feasible method of managing highly infectious waste.
The incinerator will be of the controlled air type, designed for (6-8) hour-day operations and rated at 75 kg per hour.
The incinerator plant will include the following:
• Continuous loading using hydraulic ram feeder o Burners and fuel system
o Fans
o Pumps
o Controls and Instrumentation o Chimney and flue connections
o Incinerator loader for loading hoppers or carts o Ash handling equipment
• 1 year spare parts
• Waste weighing equipment
• Wheeled 2.0m3 waste storage hoppers (number to be decided by hospital managers)
• Incinerator loader
• Incinerator building, including fire safety equipment
Incinerator with Dry Scrubber 100 kg/hra) Regulator : 1 no
b) Pyrometric Cane : 1 no
c) Burner’s Control Box : 1 no
d) Spark Electrode : 1 no
e) Flame Cell Detection : 1 no
f) Lime Stone : 1 no
g) Chamber of Combustion with door of load : 1 no
h) Burner of Combustion PRESS GV-1 allure : 1 no
i) Chamber of post combustion : 1 no
j) Burner post combustion PRESS GW-2 allure : 1 no
k) Electric panel : 1 no
l) Air fan : 1 no
m) Concreted Elements : 3 nos
n) Dry Washer : 1 no
o) Chimney Inox : 1 no