Items/Model TS300(PLC) Picture ![]()
Principle Solid Waste Incineration Treatment Burn Rate Average 300 kg/hour Feed Capacity Average 400kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 2000L Internal Dimensions 170x120x100cm Secondary Chamber 1000L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 2.0Kw Oil Consumption (kg/hour) Average 38(DO) Gas Consumption (m3/hour) Average 45.6(NG) Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 200L Feed Door 80x60cm Chimney 10Meter Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 11000kg External Dimensions 400x210x300cm(without chimney)
Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: sales@hiclover.com
Email: hicloversales@gmail.com
Nanjing Clover Medical Technology Co.,Ltd.
HICLOVER Incinerator/Parts Range | Main Feature |
Medical Waste Incinerators | HICLOVER 10-500kgs/Hr.Double Combustion Chambers |
Single Combustion Chamber | Small, Cheap,10-20kgs/Hr. |
Three Combustion Chambers(Optional) | 3 Chambers for high risk waste |
Pet Cremation Equipment | For Pet(small/big) Cremation Business |
Animal Incineration Equipment | For other animal incineration |
Items/Model | TS100(PLC) | TS150(PLC) | TS300(PLC) | TS500(PLC) |
Burn Rate (Average) | 100 kg/hour | 150 kg/hour | 300 kg/hour | 500 kg/hour |
Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. |
Combustion Chamber | 1200L | 1500L | 2000L | 3000L |
Internal Dimensions | 120x100x100cm | 150x100x100cm | 170x120x100cm | 210x120x120cm |
Secondary Chamber | 600L | 750L | 1000L | 1500L |
Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber |
Feed Mode | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V |
Power | 1.38Kw | 1.69Kw | 2.57Kw | 4.88Kw |
Diesel Oil Consumption (kg/hour) | Ave.20.4 | Ave.24.2 | Ave.33 | Ave.44 |
Natural Gas Consumption (m3n/hour) | Ave.24.5 | Ave.29 | Ave.39.6 | Ave.52.8 |
Temperature Monitor | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes |
Oil Tank | 200L | 300L | 500L | 500L |
Chimney | 10Meter | 10Meter | 14Meter | 14Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ |
2nd. Chamber Temperature | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 6000kg | 8500kg | 11000kg | 16000kg |
External Dimensions | 260x150x180cm | 300x160x190cm | 400x210x300cm | 450x210x300cm |
Controlled hygienic, mechanical or automatic feeding methods must not negatively influence the air supply and temperature in the primary and secondary chambers of the incinerator.
“Each unit shall include a diesel fuel storage tank of sufficient capacity to enable operation of the unit for 5 working days of 10 hours each.
• The unit shall include a pumping system and lines to supply the burners from the tank and the diesel-electric generator. The pumping system will have two pumps in parallel for redundancy.
• The supply lines will be fabricated from steel tubing and adequately protected and supported against damage during operations and include shutoff valves for each line.
• The unit shall be equipped with a fuel meter.
”
“The waste incinerators shall be designed for the following electricity supply:
• 3 phase, 4 wire, 415 V a.c. ±10%, 50 Hz ±3%
• 3 phase 4 wire, 220 V a.c. ±10%, 60 Hz ±3%