Incinerator design for hospitals

Items/Model TS300(PLC)
Picture

Principle Solid Waste Incineration Treatment
Burn Rate Average 300 kg/hour
Feed Capacity Average 400kg/feeding
Control Mode PLC(Programmable Logic Controller Incinerator)
Combustion Chamber 2000L
Internal Dimensions 170x120x100cm
Secondary Chamber 1000L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 2.0Kw
Oil Consumption (kg/hour) Average 38(DO)
Gas Consumption (m3/hour) Average 45.6(NG)
Temperature Monitor Digital Display
Temperature Protection Yes
Oil Tank 200L
Feed Door 80x60cm
Chimney 10Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Gross Weight 11000kg
External Dimensions 400x210x300cm(without chimney)

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: sales@hiclover.com
Email: hicloversales@gmail.com

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range Main Feature
Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers
Single Combustion Chamber Small, Cheap,10-20kgs/Hr.
Three Combustion Chambers(Optional) 3 Chambers for high risk waste
Pet Cremation Equipment For Pet(small/big) Cremation Business
Animal Incineration Equipment For other animal incineration
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 200L 300L 500L 500L
Chimney 10Meter 10Meter 14Meter 14Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 6000kg 8500kg 11000kg 16000kg
External Dimensions 260x150x180cm 300x160x190cm 400x210x300cm 450x210x300cm

Controlled hygienic, mechanical or automatic feeding methods must not negatively influence the air supply and temperature in the primary and secondary chambers of the incinerator.
“Each unit shall include a diesel fuel storage tank of sufficient capacity to enable operation of the unit for 5 working days of 10 hours each.
• The unit shall include a pumping system and lines to supply the burners from the tank and the diesel-electric generator. The pumping system will have two pumps in parallel for redundancy.
• The supply lines will be fabricated from steel tubing and adequately protected and supported against damage during operations and include shutoff valves for each line.
• The unit shall be equipped with a fuel meter.

“The waste incinerators shall be designed for the following electricity supply:
• 3 phase, 4 wire, 415 V a.c. ±10%, 50 Hz ±3%
• 3 phase 4 wire, 220 V a.c. ±10%, 60 Hz ±3%
Incinerators must be able to support different power sources (PV solar system , diesel Electric generator , local or compound mini-scale grid)

CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.

1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)

2. Auto Roll Air Filter for Clean Room