SECTION V   TECHNICAL SPECIFICATIONS OF THE INCINERATOR   General Description   The plant must have four distinct sections that demonstrate three principles of turbulence, residence time and temperature retention. The regulated sections may include but not limited to:   Overall plant layout Feed chamber/charging Primary combustion chamber Particulate scrubbers Acid gas The stack/chimney. Minimum […]
Burning Capacity: 125 kg minimum/time (3-6times/day), double chamber, double combustion system Imputing door Mouth Width (mm): 760*760 (approx.) Chimney External Diameter (mm): 300 ± 10 Combustion Improver Device: 0.11kw, Fuel consumption: 7kg/ hour (max) Re-Burning Device: Oil consumption: 5kg/h, 0.37kw, Oil consumption: 10-20kg/h Voltage: 380v/220v AC, Warranty: 1 Year, 50 Hz Per your advertisement for […]
Major components are – Ethanol, Paraffin, Silicon, Aluminium chloro hydrate, Bentone ,LPG quote for incinerators for industrial chemical wastes treatment, 1 burning rate must be Average 30kgs/h 2 inside of chamber material must be refractory concrete cement 3 it works in three system diesel oil/ Natural gas or LPG 4 voltage must be 220V 5 […]
Burning rate: 250 Kg/hr. It should be able to Operate not Less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… Design Specification: Types A, B, C, D, and E of medical waste “PYROLYTIC” combustion, by controlling the gasification of waste. The incinerator […]
“PYROLYTIC” combustion, by controlling the gasification of waste The incinerator manufacturer must avoid the release of black smoke and fine dust, during the loadings. It shall be able to reduce the volume of wastes by 98%. It shall be able to hold emission in the second burn with gas residence of not less than 2 […]
1.    Capacity of destruction in weight: 60 Kg/h. 2.    It should be able to operate not less than 10 hours/day 3.    This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… 4.    Design Specification : Types A, B, C, D, and E of medical waste 5.    “PYROLYTIC” […]
medical waste Medical Waste Incinerators ⋅ 2019年9月18日 www.imcha.net Biomedical waste dumped at Rajindra Hospital The Tribune Posing a serious health hazard to the hundreds of patients, biomedical waste has been dumped in open on the premises of the Government Rajindra … 标记为不相关 Marion commissioners to vote on 1-year deal to keep Covanta incinerator open Statesman Journal […]
1    Basic Plant Design    An approved plant must have four distinct sections that demonstrate three principles of Turbulence, Residence Time and Temperature are inbuilt in the plant design .The regulated sections may include but not limited to: Overall plant layout. Feed chamber/ charging Primary Combustion Chamber. Secondary Combustion Chamber. Particulate Scrubbers Acid Gas Scrubbers The […]
waste incinerator 每天更新 ⋅ 2019年9月18日 www.imcha.net Marion commissioners to vote on 1-year deal to keep Covanta incinerator open Statesman Journal Marion commissioners to vote on 1-year deal to keep Covanta incinerator ….. that would have designated trash incineration as renewable energy. 标记为不相关 Waste incineration levels double over five years ENDS Report The amount of municipal […]
The Incinerator Plant is output wastes incineration from Different petrochemical units. In this project we want to incinerate all output wastes from petrochemical units and also produced high pressure steam from incinerator plant heat generated. At first output waste from petrochemical collects and transfers to transit and sorting center in various forms. Input feeds of […]