Tag: incinerator

mobile incinerator

Petrol: diesel   Consumption: 8-10liter/hour   Capacity: to cremate (carrion and spoils) 350-400kg/hour   Temperature: 900-1350?C   Operation temperature: -30~40?C   Incinerator weight: 1800-2000 kg   Volume: 0.70-0.80m/cube   Exterior dimension: 1.4-1.6*1.0-1.15m (L*W) An incinerator represents a complete solution to the problem of disposal of all hospital waste types. The liquid fuel is diesel. The […]

pet incinerator

The incinerator plant shall incorporate a control panel for its operation. On the control panel we shall have a visual display of the chamber temperatures. This visual display must control and monitor the incinerator and his performance. Capacity of destruction in weight shall be 60 Kg/h. It should be able to operate not less than […]

incinerator manufacturer

“PYROLYTIC” combustion, by controlling the gasification of waste The incinerator manufacturer must avoid the release of black smoke and fine dust, during the loadings. It shall be able to reduce the volume of wastes by 98%. It shall be able to hold emission in the second burn with gas residence of not less than 2 […]

00 BEDS HOSPITAL INCENERATOR TECHNICAL INFORMATIONS

1) Policy – Waste disposal management shall be taken special note to prevent hospital infection. – Infections wastes shall be managed, stored strictly and burned by a incinerator located at hospital site.   2) Waste Disposal Plan a)Classification – Medical wastes in hospital are classified as follows;   Infections Waste Specially-controlled waste Organ, needle, etc. Industrial waste […]

TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals in Kenya

TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals   INTRODUCTION All the incinerators to be supplied and installed must meet the Government of Kenya waste Management Regulation 2006 in particular 3rdschedule regulation (26, 47) pertaining classification, standards, criteria, and procedure for installing/operating incinerators as authored by the National Environmental Management and Coordination (waste management) regulation 2006, legal […]

incinerator manufacturers

GOODS:  ONE INCINERATORS IN ACCORDANCE WITH THE   SUPPLIER’     REQUIREMENT     S OWN             PROPOSED                         SPECIFICA             TION/               CONFIRM         […]

waste incinerator manufacturer in china

Burning rate: 250 Kg/hr. It should be able to Operate not Less than 10 hours/day This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc… Design Specification: Types A, B, C, D, and E of medical waste “PYROLYTIC” combustion, by controlling the gasification of waste. The incinerator […]

incinerator manufacturer in china

1. Is the residence time more than 2 seconds? 2. Is the primary and secondary air preheated? 3. Could it be provided as a continuous system? 4. Is there a monitoring system for operational parameter? (temperature) 5. Is there a data logging system? 6. Does it provide for control interventions to adjust waste feed, grate […]