Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/ Email: sales@hiclover.com Email: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project. HICLOVER Incinerator/Parts Range Main Feature Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers Single Combustion Chamber Small, Cheap,10-20kgs/Hr. Three Combustion Chambers(Optional) 3 Chambers for high risk waste Pet Cremation […]
Tag: waste incineration
Newsletter – incinerator
incinerator Medical Waste Incinerators ⋅ 2019年10月3日 www.imcha.net Mapped: England’s waste incineration capacity gap ENDS Report The government should be “explicit” about the need for more waste incineration plants and to commit to keeping landfill tax at levels which make … 标记为不相关 查看更多结果 | Auto. Control Waste Incinerator & Auto. Roll Air Filter(Air Purification) Newsletter。 | 以RSS […]
Medical Waste Incineration Model TS20(PLC) Wet Scrubber (Water Spary tower)
Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/ Email: sales@hiclover.com Email: hicloversales@gmail.com Nanjing Clover Medical Technology Co.,Ltd. Items/Model TS20(PLC) Picture Principle Medical Waste Incineration Burn Rate Average 20 kg/hour Feed Capacity Average 40kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 210L Internal Dimensions 65x65x50cm Secondary Chamber 110L Smoke Filter Wet Scrubber (Water Spary tower) Feed Mode Manual Voltage 380V Power 5Kw Oil Consumption (kg/hour) 7.8–16.3 Gas […]
Small Medical Waste Incinerator 2 combustion chambers with scrubber
Small Medical Waste Incinerator 2 combustion chamber with scrubber for Virus medical waste On-Site Incineration Solution Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities, and medical research facilities. These wastes include both infectious (“red bag”) medical wastes as well as non-infectious, general housekeeping wastes. Items/Model TS30(PLC) Picture Burn Rate […]
Incinerator burn medical and bio waste
Incinerator burn medical and bio waste Items/Model TS100(PLC) Picture Principle Medical Waste Incineration Treatment Burn Rate Average 100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V/380V Power 0.7Kw Oil Consumption (kg/hour) average 20.4 Gas Consumption (m3/hour) *** […]
Incineration plant machine of 150kg/hr on LPG
Incineration plant machine of 150kg/hr On Lpg Items/Model TS150(PLC) Picture Principle Medical Waste Incineration Treatment Burn Rate Average 150 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1500L Internal Dimensions 150x100x100cm Secondary Chamber 750L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.9Kw Oil Consumption (kg/hour) Average 24.2(D.O) Gas Consumption (m3n/hour) Average 21.3(LPG) Temperature […]
MEDIUM-CAPACITY ANIMAL CARCASS INCINERATOR HICLOVER Model TS100(PLC)
MEDIUM-CAPACITY ANIMAL CARCASS INCINERATOR HICLOVER Model TS100(PLC) with wet scrubber optional Items/Model TS100(PLC) Picture Principle Waste Incineration Treatment(Poultry and dead fish Incinerator Machine) Burn Rate Average 50-100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 970L Internal Dimensions 120x90x90cm Secondary Chamber 480L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V-240V Power 0.7Kw […]
Pre-assembled containerized type Incinerator
Pre-assembled, containerized type Incinerator Model CA100 Picture Waste Treatment Medical Waste Incineration Treatment Feed Capacity Average 100-200 kgs per feed Burning Rate Average 100-120 kgs per hour Burning Time per Feed Average 1-2 hour Control Mode PLC(Programmable Logic Controller Incinerator) Voltage 220V Power 1.0Kw Fuel Diesel oil Burner Italy Burner Feed Mode Manual Temperature Monitor […]
Waste Incineration HICLOVER Model TS75
Waste Incineration HICLOVER Model TS75 Items/Model TS75(PLC) Picture Principle Waste Incineration Burn Rate Average 75 kg/hour Feed Capacity Average 150kg Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 770L Internal Dimensions 100x81x95cm Secondary Chamber 385L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) Average 16.9 Gas Consumption (m3/hour) *** […]
Waste Incineration Treatment BURNING RATE : 100-150kgs per hour HICLOVER TS150
BURNING RATE : -100-150kgs per hour MINIMUM OPERATING TEMPERATURE : 800-1000 oC ( PRIMARY COMBUSTION ) MAX OPERATING TEMPERATURE : 1000-1200 oC ( AFTER BURNER COMBUSTION ) SECONDARY BURNING CAPACITY : COMPULSORY DENSITY INSULATION : 50 mm high Refractory capacity : min 114mm HEAVY DUTY REFRACTING LINING TO WITHSATND 17500C AVEARGE BURN OUT TIME : […]