Tag: waste incinerator

Wet scrubber for incinerators

having waste from production process which is having very fine/powder material with moisture of 40%. Will this machine suitable for this application. For power waste, proposal plus wet scrubber system. Optional 1 section type: Wet Cooling Spray Scrubber. Function: cooling, remove dust.   Optional 3 section type: Wet Cooling Spray Scrubber+Wet Dust Scrubber+Fog and Water Separator. […]

Incineration plant machine of 150kg/hr on LPG

Incineration plant machine of 150kg/hr On Lpg Items/Model TS150(PLC) Picture   Principle Medical Waste Incineration Treatment Burn Rate Average 150 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1500L Internal Dimensions 150x100x100cm Secondary Chamber 750L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.9Kw Oil Consumption (kg/hour) Average 24.2(D.O) Gas Consumption (m3n/hour) Average 21.3(LPG) Temperature […]

hospital for burning hazardous waste and chimicals

use in the hospital for burning hazardous waste and chimicals, minimal Capacity 300 per hour. I’ll be reselling to my customer? . Below is the advice I was given and nothing else. The hospital incinerator for use in the clinical waste as required by global environmental management. Minimum temperature of 1100 degree Celsiu.the incinerator machine […]

Incinerator burn medical and bio waste

Incinerator burn medical and bio waste Items/Model TS100(PLC) Picture   Principle Medical  Waste Incineration Treatment Burn Rate Average 100 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V/380V Power 0.7Kw Oil Consumption (kg/hour) average 20.4 Gas Consumption (m3/hour) *** […]

Double Combustion Chamber Containerized Mobile Incinerator

Double Combustion Chamber Waste Incinerator Mounted in ISO 20′ or 40′ Container before leave Factory. Free Installation The incinerator design with primary combustion chamber, secondary combustion chamber(post combustion) and dry scrubber optional. This layout will reduce black smoke, burn completely and Environmentally Friendly. Mobile Incinerator The incinerator mounted already in the container, complete with fuel […]

Incinerator YD-150 with Stainless Steel Wet scrubber-Cooling Spray tower

Model YD-150 Burning Rate Average 150 kgs/hour Feed Capacity Average 300 kgs/feeding Primary Combustion Chamber 1500 Liters Secondary Combustion Chamber 500 Liters Mix Combustion Chamber Yes Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V/380V Power 1.03Kw Fuel Type Diesel Oil/ Natural Gas/LPG Burner Italy Original Oil Consumption (Diesel Oil) 17–36 kg/hour Gas Consumption (Natural […]