HICLOVER Incinerator/Parts Range
Medical Waste Incinerators | HICLOVER 10-500kgs/Hr.Double Combustion Chambers |
Single Combustion Chamber | Small, Cheap,10-20kgs/Hr. |
Three Combustion Chambers(Optional) | 3 Chambers for high risk waste |
Pet Cremation Equipment | For Pet(small/big) Cremation Business |
Animal Incineration Equipment | For other animal incineration |
Temperature Control, Primary and Secondary
Stoking tools
Stainless Steel Spark Screen
Primary Chamber Door Locking System
HICLOVER Solution for Fighting COVID-19, with ISO9001:2015/CE(2006/42/EC,2014/30/EU) Certification.
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
2. Auto Roll Air Filter for Clean Room(Air Purification)
Nanjing Clover Medical Technology Co.,Ltd.
Tel: +86-25-8461 0201
Mobile: +86-138139 31455
WhatsApp: 008613813931455
WhatsApp: 008615380948599
Twitter ID: @hiclovercom
Wechat: 008613813931455 (ID: hiclovercom)
Wechat: +8615380948599 (ID: wasteincinerator)
Website1: www.hiclover.com
Website2: www.clover-incinerator.com
Email1: sales@hiclover.com
Email2: hicloversales@gmail.com
Email3: sales@clover-incinerator.com
Email4: cloverincinerator@gmail.com
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) |
Brand | HICLOVER | HICLOVER | HICLOVER | HICLOVER |
Burn Rate (Average) | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour |
Feed Capacity(Average) | 20kg | 40kg | 60kg | 100kg |
Control Mode | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm |
Secondary Chamber | 50L | 110L | 180L | 280L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 |
Temperature Monitor | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ |
2nd. Chamber Temperature | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm |
Prefabricated Incinerator with a concrete base and chain link fence.The incinerator should be portable, very easy to install, allow for re-location, fit in small space with a chimney length of 4m to drive smoke away to safe heights and also cause current flow of fresh air to drive moisture out of the rubbish such that the bad odour from sanitary pads is removed and the waste is dried automatically. The incinerator should be made of a non-rusting material such as stainless steel of 4mm gauge. It should not require an extra heat source, but use the heat generated from burning of the solid waste as its major energy source. This incinerator should be capable of raising temperature to its maximum within three minutes and the heat losses kept to the minimum.Average Temperature
Average Temperature; 850 degrees Cent grade (As per Ministry of Health)
Capacity Capacity; 60 Liters, Auto combustion/nonfuel assisted
Destruction rate 30 liters per hour, waste reduction up to 95%volume
Batch Load 5Kgs per load
Life Span Life span; minimum 10 years
Items/Model | TS100(PLC) | TS150(PLC) | TS300(PLC) | TS500(PLC) |
Burn Rate (Average) | 100 kg/hour | 150 kg/hour | 300 kg/hour | 500 kg/hour |
Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. |
Combustion Chamber | 1200L | 1500L | 2000L | 3000L |
Internal Dimensions | 120x100x100cm | 150x100x100cm | 170x120x100cm | 210x120x120cm |
Secondary Chamber | 600L | 750L | 1000L | 1500L |
Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber |
Feed Mode | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V |
Power | 1.38Kw | 1.69Kw | 2.57Kw | 4.88Kw |
Diesel Oil Consumption (kg/hour) | Ave.20.4 | Ave.24.2 | Ave.33 | Ave.44 |
Natural Gas Consumption (m3n/hour) | Ave.24.5 | Ave.29 | Ave.39.6 | Ave.52.8 |
Temperature Monitor | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes |
Oil Tank | 200L | 300L | 500L | 500L |
Chimney | 10Meter | 10Meter | 14Meter | 14Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ |
2nd. Chamber Temperature | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 6000kg | 8500kg | 11000kg | 16000kg |
External Dimensions | 260x150x180cm | 300x160x190cm | 400x210x300cm | 450x210x300cm |
CE and ISO Certification Pass Incinerators