Q: what is kind of waste can use in this equipment?
A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard
A: China Government Standard: No.GB18484-2001.
Q: Treatment capacity
A: Average Capacity calculated by medical waste(lower calorific power (L.C.P): 3.0TH Kcal/Kg per hour),
not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours.
The lifetime of incinerator between 5-10 year according to use.
Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. When incinerator
use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are
200 sickbed in the hospital, that’s mean you need one incinerator capacity around 400kgs per day, change
to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material,
budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator.
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing
A: We supply all documents and incinerators easy to installation and operation. Customer can send people
come to our factory to learn installation and operation. Generally, We do not send engineer to local
site if not request. The dispatch cost is extra according to order.
Q: Combustion Temperature
A: The first combustion chamber: 800-1000 centi degree.
The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode
A: Default Control mode is common control case. PLC mode according to model and order.
Q: Operation and maintenance costs
A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000usd per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to
operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and
know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.
Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate (Average) | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity(Average) | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ |
2nd. Chamber Temperature | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Provide incinerator with a capacity of not less than [75] kg per hour, based on operating the incinerator no
more than 8 hours continuously per day, and to be suitable for burning medical waste parts which have a water content as high as 85 percent by weight.
Provide furnace with an inside volume, exclusive of the space occupied by the refractory hearths and walls,
of not less than 2 cubic meters with a primary combustion chamber volume above the burning hearth of not
less than 1.5 cubic meters, Provide a complete waste burning system including combustion air fan, primary
and secondary burners, air distribution and burner controls, ducts, breeching, stack, bottom ash conveyor
and collection, feed rams, fire tube water tube, air compressors, slurry pumps, water pumps, fly ash collection system.
Construct the primary chamber with a steel casing supported by a steel frame, and provide with insulation
and refractory. Make the casing with 5 mm sheet steel minimum, conforming to ASTM A1011/A1011M and
reinforced to withstand internal pressures without deflection or damage to refractory or other components
of the incinerator. Construct the frame and all reinforcing members of steel conforming to ASTM A36/A36M. Provide a free-standing frame capable of supporting the weight of all components of the incinerator, including doors,
burners, breeching, stack connections, and appurtenant assemblies without binding or warping.
Make the frame and casing of all welded construction, completed and erected prior to installation of the
refractory and insulation. Provide all access doors and parts with seals to prevent emission of smoke or
admission of significant amounts of air during incinerator operation, and a primary chamber with no
openings which would permit leakage of waste fluids.