Incinerator for Waste Management Facility and Spare Parts

Items/Model TS500(PLC)
Picture

Principle Waste Incineration Treatment
Burn Rate Average 500 kg/hour
Control Mode PLC(Programmable Logic Controller Incinerator)
Combustion Chamber 2700Liters (2.7m3)
Internal Dimensions 190x120x120cm
Secondary Chamber 1300Liters (1.3m3)
Smoke Filter Chamber Dry Scrubber Chamber
Feed Mode Manual
Voltage 220V
Power 3.0Kw
Oil Consumption (kg/hour) Average 44(DO)
Gas Consumption (m3n/hour) Average 53(NG)
Temperature Monitor Digital Display
Temperature Protection Yes
Oil Tank 400L
Feed Door 90x80cm
Chimney 10Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Gross Weight 15000kg
External Dimensions 400x210x300cm(without chimney)

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: sales@hiclover.com
Email: hicloversales@gmail.com

Nanjing Clover Medical Technology Co.,Ltd.

Supply. Delivery. Insta llation, Commissioning a nd Maintenance of Industria l Standard Solid Waste lncinerator.CONTRACTOR shall be responsible to supply on-the – shelf industrial solid wast e incinerator and its accessories in the market and/or fabr icate its auxiliary related equipment for comprehensive functionalities. Capac ity 500 kg/ hour {dual chamber inc ineration) electricity from garbage
1.Primary Chamber – Destruction of Mater ial (>850°C) .
2.Secondary Hazar dous carcinogenic destroyed).
Chamber – Destruction of Gas (>1200°C to ensure induced gases is fully Waste type Compatibility
General Wastes/Industrial Wastes/Bur nable
Wastes/Medic al Wastes/Oily
Sludge/ Contaminated Soil/ Saw Dust.
Fuel type Dual Type (Diesel and Gas)
Secondary Chamber &
A ir Pollution Control (APCS) Capabilities
System Compa ny declaration that the equipment is capa ble to remove VOC’s. CO, No×,Dio×ins
& Furans (through high temperature f iltration), particulate matter. Heavy Metals (Pb, As, Sb, Cd, 丁I) – Result from an accredited lab.
2.Blac k smoke control technology : Dry scrubber, longer residence time in secondar y c ha mber (to ensure complete combustion, kill virus) .

HICLOVER Incinerator/Parts Range Main Feature
Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers
Single Combustion Chamber Small, Cheap,10-20kgs/Hr.
Three Combustion Chambers(Optional) 3 Chambers for high risk waste
Pet Cremation Equipment For Pet(small/big) Cremation Business
Animal Incineration Equipment For other animal incineration

incinerator design for schools

Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 200L 300L 500L 500L
Chimney 10Meter 10Meter 14Meter 14Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 6000kg 8500kg 11000kg 16000kg
External Dimensions 260x150x180cm 300x160x190cm 400x210x300cm 450x210x300cm