Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting gaseous products are completely oxidized in the secondary chamber at higher temperatures with sufficient resident time. Other specifications are as follows. A combustion chamber of waste:
* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load
* A burner of lighting which the use is limited to the ignition of waste.
* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminum and insulates bricks in order to assure a minimum temperature on the outside sheet metal.
* Composition of the refractory
Burning Capacity | Max. 200kgs/h | |
Auxiliary Fuel | Diesel | |
Type of Burner | Monoblock automatic burners | |
Temperatures | Primary Chamber: 800°C ± 50°C
Secondary Chamber: 1300°C ± 50°C |
|
Type | Static solid hearth | |
Material of Construction | Mild Steel | |
Refractory thickness | 115 mm thick | |
Material | Refractory bricks | |
Insulation thickness | 50 mm thick | |
Waste Charging | Manual | |
Ash Removal | Manual | |
Type | Static solid hearth | |
Material of Construction | Mild Steel | |
Refractory thickness | 115 mm thick | |
Material | Refractory bricks | |
Insulation thickness | 50 mm thick | |
Type | Centrifugal | |
Modulation | Manual damper control | |
Material of Construction | Mild Steel | |
Type of temperature controller | Digital | |
Finish & painting type | Double coat | |
Material of construction & capacity | Mild Steel/ Plastic, suitable capacity | |
Other Standard Accessories | Diesel oil level indicator, piping with valves & Non-return valve | |
Visual Checking of Fuel | Provided | |
No. of Burners | 2 one in primary and in secondary chamber) | |
Type & Model | Monoblock automatic oil fired | |
Make | Riello | |
Fuel | Diesel | |
Fuel delivery | 10 20 kg/h | |
Firing stage | 1 | |
Thermal power | 118 236 kW | |
Motor power | 240 W | |
Pump pressure | 10 12 bar (standard calibration), Max. pressure 15 bar | |
Electrical supply | Single phase 220V, 50Hz. | |
Material of construction | Burnt bricks | |
Height | 9 meters from ground level |