Nanjing Clover Medical Technology Co.,Ltd.

Capacity: Average 300 kgs per hour

Model YD-300
Picture

Burning Rate Average 300 kgs/hour
Feed Capacity Average 500 kgs/feeding
Primary Combustion Chamber 2400 Liters
Secondary Combustion Chamber 1200 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Wet Scrubber System(3 Section Type)
Feed Mode Manual
Voltage 380V
Power 12.0 Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) Average 33kg/hour
Gas Consumption (Natural Gas) ***
Internal Dimensions 220 x 110 x 100cm (primary chamber)
External Dimensions 260 x 220 x 420cm (without chimney/wet scrubber)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 500 Liters
Door Opening 90 x 110cm
Chimney Length 10.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 14000 kgs
Operation Technical Specifications
Primary Chamber Temperature 800℃–1000℃
Secondary Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Burning Efficiency >98%
Waste Lower Calorific Power 3000Kcal