Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can use within this equipment? A: This equipment to medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour)doesn’t mean any waste material. The animal/pet combustion speed around 2/3 of ordinary power.
Clover incinerator use time daily to 24 hours. Between each feed/combustion time, you will find about 0.5-1 hours cooling time plus time for feeding waste. The life of incinerator between 5-10 year according to use.
Generally, we proposition small laboratory, small clinic use capacity under 20 kgs per hour. If incinerator use in hospital, please calculate the waste output around 2kgs per people every day. If there are 200 sickbed at the clinic, that’s mean you need one incinerator capacity around 400kgs per day, change to power per hour is approximately 30-40 kgs per hour. According the performance time every day, waste material, budget, growth, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Meeting and Testing A: We provide all files and incinerators easy to installation and functionality. Customer can send people visit our factory to find out operation and installation. Generally, we don’t send engineer to neighborhood site if not ask. The dispatch cost is extra according to order. The next combustion chamber: 1000-1200 centi level. PLC mode according to model and order.
Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD annually maintenance according model, use situation.
One person can service 02 device incinerators. The staff must have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to performance consumer guider, and know risk of medical waste to safeguard worker self with necessary protection component.
Q: The Residency period in combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |