Product Description
Technology Respond(FAQ)
Q: What is kind of waste can use within this equipment? A: This equipment for medical waste, pet creature, Municipal waste, live waste. Prohibit any volatile and radiation material, liquid waste and gas waste. GB18484-2001. The animal/pet combustion speed around 2/3 of ordinary capacity.
Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are approximately 0.5-1 hours cooling time and time for feeding waste. Actual combustion time daily is around 16 hours. The life of incinerator involving 5-10 year based on use.
Generally, we proposition little lab, little clinic use capability under 20 kgs per hour. If incinerator use in hospital, please calculate the waste output capacity around 2kgs per individuals each day. If there are 200 sickbed in the clinic, that’s imply you need one incinerator capability around 400kgs per day, switch to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, funding, growth, etc, you can use capacity from 30-50 kgs each hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Meeting and Testing A: We supply all files and incinerators simple to installation and functionality. Customer can send individuals come to our factory to find out installation and operation. Small scale medical waste incinerator, syc-30 incinerator, waste incinerator manufacturer China, Generally, We do not send engineer to neighborhood website or even ask. The dispatch cost is extra based on order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi level. The next combustion chamber: 1000-1200 centi level. PLC mode based on model and order.
Q: Operation and maintenance costs A: Operation cost based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD annually maintenance according version, use situation.
One individual can service 02 device incinerators. The staff should have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and understand threat of medical waste to protect worker self with essential protection element.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |