***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber***Chimney:10.0Meters***Incinerator PLC Control Case***Italy oil/gas burner: 02 units
***Oil Tank (if oil fuel): 200Liters
Items/Model TS100(PLC) Principle Waste Incineration Treatment Burn Rate Average 100 kg/hour Feed Capacity Average 200kg/feeding Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes(Dry Scrubber) Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 14–28 Gas Consumption (m3/hour) 10–32.2 Temperature Monitor Digital Display Temperature Protection Yes Oil Tank 200L Feed Door 80x60cm Chimney 10Meter Chimney Type Stainless Steel 1st. Chamber Temperature 800℃–1000℃ 2nd. Chamber Temperature 1000℃-1200℃ Residency Time 2.0 Sec. Gross Weight 6000kg External Dimensions 260x150x180cm