Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can use in this gear? A: This gear for medical waste, pet creature, Municipal waste, reside squander. Prohibit any volatile and radiation material, liquid gas and waste waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion speed around 2/3 of average power.
Clover incinerator use time daily to 24 hours. Between each feed/combustion time, there are approximately 0.5-1 hours cooling time and time to get feeding squander. Laboratory incinerator china maker, big animal incinerators, low-cost medical waste incinerator, pet crematory, pet incinerator deisel, pet incinerators, Real combustion time per day is about 16 hours. The life of incinerator between 5-10 year based on use.
Ordinarily, we proposition little lab, little clinic use capacity under 20 kgs per hour. When incinerator use in hospital, then please calculate the waste output capacity around 2kgs per individuals every day. If there are 200 sickbed in the hospital, that’s mean you need one incinerator capacity around 400kgs every day, switch to power per hour is around 30-40 kgs per hour. According the operation time every day, waste material, funding, development, etc, you can use capacity from 30-50 kgs each hour incinerator. *The best way to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We provide all files and incinerators simple to installation and functionality. Customer can send individuals visit our factory to learn installation and operation. Generally, we don’t send engineer to neighborhood site if not request. The dispatch price is additional based on order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi degree. The next combustion chamber: 1000-1200 centi degree. PLC mode based on model and order.
Q: Operation and maintenance costs A: Operation price based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD annually maintenance according model, use situation.
One person can service 02 unit incinerators. The team should have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower in accordance with operation user guider, and know risk of medical waste to safeguard worker self with mandatory security element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |