lab incinerator china producer

Incinerator double chamber with capacity 1.5 m3/batch or 6 m3/ day, digital thermocontrol array 0‐1200 C, thermocouple, air supply capacity 10m3/ min, power use 1.2 kWH/ hr, power 3 stage with netral, cooling water sprinkler ability 5L/ minute, finished with refractory (insulation, castable, ceramic covering) and also PLC SUPPLY, INSTALLMENT In Addition To COMMISSIONING OF […]

diesel oil fired medical waste incenerator

Heat Waste Incinerator Layout D. MEGABYTES 750XL Melt Rate-150Kg/ hr minimum Weight( Kg) -4000 kg Added Chamber (double chamber with post-burning) Gas Retention Time 2 2nd Gas Diesel Power Supply for control box 220V-240, solitary phase 50-60Hz Minimum operating temperature degree 1200 oC One year extra parts bundle for full maintainability 10m pipe pipe. 1100 […]

garden incinerator

c) All manuals must be in English language.   9)  Each of the equipment supplied must be provided with user and technical manuals. Instructions on their usage, storage and service must be clearly indicated in the manuals and where necessary, on the equipment.   10)Where applicable the following shall apply: a) Electrical Safety i) The […]

maker of ha zardous waste heater in china

Burning Capability: 125 kg minimum/time (3-6times/ day), twin chamber, double burning system Assigning door Mouth Size (mm): 760 * 760 (approx.). Smokeshaft External Size (mm): 300 ± 10. Combustion Improver Tool: 0.11 kw, Fuel intake: 7kg/ hr (max). Re-Burning Tool: Oil intake: 5kg/h, 0.37 kw, Oil usage: 10-20kg/ h. Voltage: 380v/220v Air Conditioning System, Service […]

incinerator for medical waste

MINIMUM REQUIREMENTS FOR ENGINE OF INCINERATION CAPACITY OF INCINERATION 30KG / H 1. GENERAL SPECIFICATIONS: The incinerator for medical waste must be designated for the destruction of all types of waste produced by the Center for Health (waste type hospital, clinic, medical laboratory for destructive capacity of 30kg / h) . Pyrolytic gasification combustion control […]

China incinerator

Burner Of Burning Capacity 30 kg/hr = 1 No The Incineration System contains: I. Main Heater with A. Refractory lined Key as well as Added Chamber. B. Refractory lined main billing door as well as ash cleansing door. II i. 1 No. totally automated oil heating unit for major chamber. III.Centrifugal required draft combustion air […]

300 kg incinerator

i) Patient and operator safety and system performance should not be adversely affected by fluid spills. ii) If the unit is affected, it should fail safely.   c) Overcurrent Protection i) Loss of power to other equipment on the same branch circuit due to internal equipment faults should be prevented by using fuses or circuit […]

china incinerator supplier

f) Alarms i) The unit should have visual or audible alarms to warn operators of any system fault that may cause unsafe or erroneous results. ii) Audible and/or visual indicators should activate when the display reading reaches and remains at the alarm limit. iii) All alarms should be fully explained in the operator’s manual.   […]