How medical waste is incinerated?
The pyrolytic incinerator comprises a pyrolytic chamber and a post-combustion chamber. Medical waste is thermally decomposed in the pyrolytic chamber through
an oxygen-deficient, medium-temperature combustion process (800– 900°C), producing solid ashes and gases.
What are the treatment methods for treatment of bio medical waste?
Thermal processes
Low-heat systems (operates between 93 -177oC) use steam, hot water, or electromagnetic radiation to heat and decontaminate the waste
High-heat systems employ combustion and high temperature plasma to decontaminate and destroy the waste. …
Incineration.
Autoclaving.
Microwaving.
Deep Burial.
Nanjing Clover Medical Technology Co.,Ltd.
waste to energy plant suppliers
medical waste incinerator types
hospital waste disposal methods
ovens incineration sale
medical waste incinerators in south africa
where and how incinerator install
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | |
Burn Rate (Average) | 10-20 kg/hour | 20-30 kg/hour | 30-50 kg/hour | 50-100 kg/hour | |
Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. | |
Combustion Chamber | 100L | 210L | 330L | 560L | |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | |
Secondary Chamber | 50L | 110L | 180L | 280L | |
Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber | |
Feed Mode | Manual | Manual | Manual | Manual | |
Voltage | 220V | 220V | 220V | 220V | |
Power | 0.75Kw | 0.83Kw | 0.99Kw | 1.2Kw | |
Diesel Oil Consumption (kg/hour) | Ave.8.4 | Ave.10.9 | Ave.13.3 | Ave.16.9 | |
Natural Gas Consumption (m3n/hour) | Ave.10.1 | Ave.13 | Ave.16 | Ave.20.2 | |
Temperature Monitor | Yes | Yes | Yes | Yes | |
Temperature Protection | Yes | Yes | Yes | Yes | |
Items/Model | TS100(PLC) | TS150(PLC) | TS300(PLC) | TS500(PLC) | |
Burn Rate (Average) | 100-150 kg/hour | 150-200 kg/hour | 300-400 kg/hour | 500-600 kg/hour | |
Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. | |
Combustion Chamber | 1200L | 1500L | 2000L | 3000L | |
Internal Dimensions | 120x100x100cm | 150x100x100cm | 170x120x100cm | 210x120x120cm | |
Secondary Chamber | 600L | 750L | 1000L | 1500L | |
Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber | |
Feed Mode | Manual | Manual | Manual | Manual | |
Voltage | 220V | 220V | 220V | 220V | |
Power | 1.38Kw | 1.69Kw | 2.57Kw | 4.88Kw | |
Diesel Oil Consumption (kg/hour) | Ave.20.4 | Ave.24.2 | Ave.33 | Ave.44 | |
Natural Gas Consumption (m3n/hour) | Ave.24.5 | Ave.29 | Ave.39.6 | Ave.52.8 | |
Temperature Monitor | Yes | Yes | Yes | Yes | |
Temperature Protection | Yes | Yes | Yes | Yes |
All incinerators shall meet the following emission and operating standards:
• Combustion efficiency (C.E.) shall be at least 99.0%
• The combustion efficiency shall be computed as follows:
o C.E = (CO2 X 100) / (%CO2 +%CO)
Suitably designed pollution control devices such as scrubbers, filters or electrostatic precipitators,
shall be installed/retrofitted with the incinerator to achieve emission limits.”
“Each unit shall include a complete vertical exhaust and stack system, including the following features:
• Steel construction.
• Refractory lining in the lower section.
• The exit height of the stack shall be not less than a range of 3-12 metres above ground level depending
on the capacity of the incinerator unit.
• The diameter of the stack shall be selected by the Contractor to deliver an exhaust exit velocity of not
less than 10 metres per second vertically upwards when at full scale operation.
• An emission stack sampling port shall be included immediately above the secondary chamber.
HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)
Mobile: +86-138139 31455(WhatsApp)
Website: www.hiclover.com
Email: sales
Email: hicloversales