Waste Incineration Treatment BURNING RATE : 100-150kgs per hour HICLOVER TS150

BURNING RATE : -100-150kgs per hour

MINIMUM OPERATING TEMPERATURE : 800-1000 oC ( PRIMARY COMBUSTION )

MAX OPERATING TEMPERATURE : 1000-1200 oC ( AFTER BURNER COMBUSTION )

SECONDARY BURNING CAPACITY : COMPULSORY

DENSITY INSULATION : 50 mm high

Refractory capacity : min 114mm

HEAVY DUTY REFRACTING LINING TO WITHSATND 17500C

AVEARGE BURN OUT TIME : MAXIMUM 3HRS

FUEL TYPE : FUEL OIL ( DIESEL )

FUEL CONSUMPTION IN LTRS/HR : average 14

RESIDNECY TIME IN SECONDARY CHAMBER : 2 STAGES

Items/Model TS150(PLC)
Picture

Principle Waste Incineration Treatment
Burn Rate Average 100-150 kg/hour
Feed Capacity Average 750kg/feeding
Control Mode PLC(Programmable Logic Controller Incinerator)
Chamber Material High Alumina Fire Brick Wall, 1750℃ Rate
Paint for outside face 800°C Rate
Combustion Chamber 1570L
Internal Dimensions 150x100x105cm
Secondary Chamber 750L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 210/230V 50/60Hz
Power 0.9Kw
Oil Consumption (Liter/hour) Average 14(D.O)
Gas Consumption (m3/hour) ***
Temperature Monitor Digital Display
Temperature Protection Yes
Oil Tank 2000L
Feed Door 80x60cm
Chimney 10Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Gross Weight 8500kg
External Dimensions 300x160x280cm(without chimney)