Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: sales@hiclover.com
Email: hicloversales@gmail.com
Nanjing Clover Medical Technology Co.,Ltd.
HICLOVER Incinerator/Parts Range | Main Feature |
Medical Waste Incinerators | HICLOVER 10-500kgs/Hr.Double Combustion Chambers |
Single Combustion Chamber | Small, Cheap,10-20kgs/Hr. |
Three Combustion Chambers(Optional) | 3 Chambers for high risk waste |
Pet Cremation Equipment | For Pet(small/big) Cremation Business |
Animal Incineration Equipment | For other animal incineration |
what are the main products of incineration process
Maximum load of the camera (kg) | 1200 | 1200kgs |
Overall dimensions (without burner), (mm) | 2823x1970x1724 | 500x220x190cm(without chimney) |
2823x1970x1724 chamber Volume, m3 | 2.5 m3 | 300*100*100 cm, 3.0m3 |
EXT.main camera size | (d)2392x (b)1140 | ??? |
Size of loading opening, (mm) | (W)1152x (l)1425 | W.1000*L.2000mm |
Combustion temperature (C0) | 650° – 1100° | 800℃–1200℃ |
Weight (kg) | 4500 | 7000kg |
Weight of residues after combustion (kg) | no more than 5% | no more than 5% |
Opening the hatch with a winch | availability | power-driven |
The method of loading | the vertical | Top Feeding Door |
Burners | Gas burners | Gas burners |
Fire-resistant gasket,
why is medical waste a problem |
Z-blok fire-resistant gasket | Fire Brick and Refractory castable |
Pipe dimensions (diameter, length) (mm) | 1420×3000 | ??? |
Availability of fire-resistant gaskets | Yes | yes |
Temperature properties of the gasket (C0) | 1650° | 1700°C |
Lining layer (fireclay brick)(mm) | 114 | 114mm |
Temperature properties of the lining (C0) | 1650° | 1700°C |
burner gas (m3 / h) | 9.9-17 m3 / h | 22.8m3n/h max. |
Burn rate (kg / h) | 300-450 | 300-450 |
Electricity (volts/Hz) | 220/50 Hz | 220/50 Hz |
Auto-ignition | Auto-ignition Yes | Auto-ignitio |
Temperature sensor | availability | availability |
Automatic control panel | the presence of | yes |
Burn time at full load (hour) | 4-8h | yes |
Compliance of MPV and MPC emissions | corresponds to | China Standard |
Painting | heat-resistant enamel | yes |
Items/Model | TS100(PLC) | TS150(PLC) | TS300(PLC) | TS500(PLC) |
Burn Rate (Average) | 100 kg/hour | 150 kg/hour | 300 kg/hour | 500 kg/hour |
Control Mode | PLC Auto. | PLC Auto. | PLC Auto. | PLC Auto. |
Combustion Chamber | 1200L | 1500L | 2000L | 3000L |
Internal Dimensions | 120x100x100cm | 150x100x100cm | 170x120x100cm | 210x120x120cm |
Secondary Chamber | 600L | 750L | 1000L | 1500L |
Smoke Filter Chamber | Dry Scrubber | Dry Scrubber | Dry Scrubber | Dry Scrubber |
Feed Mode | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V |
Power | 1.38Kw | 1.69Kw | 2.57Kw | 4.88Kw |
Diesel Oil Consumption (kg/hour) | Ave.20.4 | Ave.24.2 | Ave.33 | Ave.44 |
Natural Gas Consumption (m3n/hour) | Ave.24.5 | Ave.29 | Ave.39.6 | Ave.52.8 |
Temperature Monitor | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes |
Oil Tank | 200L | 300L | 500L | 500L |
Chimney | 10Meter | 10Meter | 14Meter | 14Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ |
2nd. Chamber Temperature | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 6000kg | 8500kg | 11000kg | 16000kg |
External Dimensions | 260x150x180cm | 300x160x190cm | 400x210x300cm | 450x210x300cm |
A heat exchanger to pre-heat air destined for the primary chamber is not compulsory but recommended.
The combustion air systems and fans shall be designed to ensure high combustion efficiency and avoid a reducing (corrosive) atmosphere, incomplete burnout of the flue gases and related problems. It should also be possible to heat the primary air from 10°C to approximately 145°C, depending on the waste composition and moisture content.
“The incinerator shall be designed and equipped to be installed, commissioned and operated in such a way as to prevent emissions into the air giving rise to significant ground-level air pollution; in particular, exhaust gases shall be discharged in a controlled fashion by means of a stack the height of which is calculated in such a way as to safeguard human health and the environment.
CE Certification Pass
HICLOVER Solution for Fighting COVID-19 with CE Certification.
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
2. Auto Roll Air Filter for Clean Room
2021-02-23