what is medical waste management

Item Specification
Model YD-20C
Main Product List

Primary Combustion Chamber
Secondary Combustion Chamber
Mix-Combustion Chamber
Smoke Filter Chamber
Incinerator Control Case
Chimney:5.0Meters *(upgrade to Stainless Steel, free cost)
Italy oil burner: 02 sets
Oil Tank: 100Liters

Optional:

Mobile Trailer for Incinerator

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: sales@hiclover.com
Email: hicloversales@gmail.com

Nanjing Clover Medical Technology Co.,Ltd.

bio medical waste management ppt 2020

HICLOVER Incinerator/Parts Range Main Feature
Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers
Single Combustion Chamber Small, Cheap,10-20kgs/Hr.
Three Combustion Chambers(Optional) 3 Chambers for high risk waste
Pet Cremation Equipment For Pet(small/big) Cremation Business
Animal Incineration Equipment For other animal incineration

The secondary chamber must comply with the following minimum criteria:
“• Heavy steel construction
• An excess air and high temperature operational mode.
• Sufficient size and appropriate geometry to achieve a gas temperature of at least 1000 Celsius for a retention time of at least 2 seconds when pre-heated and correctly operated.
• Sufficient forced air inflow and airflow and fuel supply controls to ensure an exhaust gas oxygen content range of 6-12% at all times.
• Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm.
• Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm.
• Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints
• An electrically powered fan forced air supply, with the capacity for variation by the operator.
• One or more fuel burners designed to use diesel fuel type 2 (vehicle standard) equipped with a spark igniter.
• A digital thermometer with connected to an electronic datalogger. The thermometer shall be located on the chamber wall away from the fuel burner.

Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 200L 300L 500L 500L
Chimney 10Meter 10Meter 14Meter 14Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 6000kg 8500kg 11000kg 16000kg
External Dimensions 260x150x180cm 300x160x190cm 400x210x300cm 450x210x300cm

CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.

1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)

2. Auto Roll Air Filter for Clean Room

2021-02-21