Blog

Clinical Waste Incinerators


Incinerator yet the measurement of chamber > > 2000 x >> 1200 mm. Prepare for burn FLUID Waste +/- 20 liter/hr.
Continual by Heavy OIL Burner.waste disposal incinerator, with the capability of taking care of both completely dry as well as damp rubbish. That consist of house hold wastes along with dry fallen leaves.
The chamber of the burner ought to have the capability to hold about 200 – – – – 250 kg of waste at an offered time. edical Waste Incinerators.
The mobile device is our top priority after that the cared for devices. Clinical Waste Incinerators. The mobile system is our priority afterwards the dealt with systems.
a; Establish Ability for each design, just how much bunches can we place in one-time. I require tio under stand in term of set load single I can ut in Kgs.
b: Burning capability per hr, to recognize simply just how much time it will definitely take to melt one collection and what is cooling timem each.
c: The quantity of collection can we place in each day basis per 1 day.
d: Most of systems will definitely be worked with Gas, so I require to comprehend the needed stress of gas in psi to run the system without any issue.
e; I do prefer to recognize a common life of system as well as after the quantity of years we need the fixing solution of linning and so on.

2. What is your minimum ability and also optimum capability burner.

3. You do offer secodn hand burner in excellent working condition.
4. We require just double chamber twin heating unit incinerator.
5. Please send us DEFRA and DADR consent records by accessory, copy of ISO along with recap of gas emmission report from heaters.


nanjing clover incinerator price


Significant incinerators – – – – INDUSTRIAL INCINERATORS – – – specifications listed below.

2.) Measurement requirement for the heaters is 750 — — — — 850 kg ability

3.) The bum price require to be 80 LL 100 kg/ hour.

4) The key chamber shouId have an operating temperature level of 900 -1200 degree C.

5) The incinerator should despise a heat 2nd chamber along with 2 second gas
retention time at 850- 1150 degree C so that it appropriates for high risk materials.

6). The incinerator needs to have temperature degree surveillance and also thermostat control for simplicity of
procedure as well as also warranty of lower temperature to confirm ideal treatment.

7). The heater should can shedding any one of the contaminateds materials detailed in the
subsequent location.

8) The burner need to can burning diesel oil and additionally need to consist of a bigger gas
container (10-500 litres) as well as likewise generator (3 –– – – 40 kV) developed that can be carried on the trailer with the
incinerator to see to it that the device needs no exterior electrical power supply.

9.) The heater requires to be trailer installed to ensure that it is a po

Infected products to be Blazed

Hazardous strong chemical:

Various types of flammable solids, used fabrics, oil, along with toner cartridges, chemicals
for water filtration as well as picture consumables and also plastic item, vacant
plastic/metal containers that still have residue hazardous product, oil absorbing.

Damaging fluid chemical:

Normally different kinds. of Acid, Paint, Varnish, Acetone, White Spirit Aromatic-less
Solvents, Artificial Fluid for Break Solutions, Aircraft De-icing Fluid, Hydraulic as well as
Compressor oil, Freon, utilized in some older refrigeration systems, Pesticide liquid/spray, air
freshen spray and various other comparable chemicals.

Contaminated gas:
Primarily diesel or gasoline contaminated by water or solvents.

Used and/or Infected oil:

Taken advantage of electrical motor oils and/or mineral oils unfit for their originally meant use. Primarily electrical motor
as well as likewise transmission oil (approximately 80%) polluted by a mix of white spirit and likewise acetone (concerning 51%), hydraulic fluid (about 5%).

Contaminated water:

Waste oilshvater, seeps, hydrocarbons/water blends, services as well as also leachate.

Polluted dirt:

Soil infected by oil, gas or 11 chemicals.
Polluted soil polluted by chemicals that needs to be reused in land fill.
Contaminated dirt—— — — dealt with as well as changed on web site.

Oil Infected Solids
Cloths, Absorbents, Cardboard, oil and additionally gas filters, air filters are dismiss as unsafe materials.

Electronic waste:

Waste digital or electric house appliances or settings up, consisting of printed circuit card,
including toxic material and/or heavy metal and/or emitting low radiation.

Used battery cells:

Dry battery, UPS battery or other kinds, unsorted waste batteries/ battery cells, having
items that are hazardouy.

Used lead-acid batteries:
Waste lead-acid batteries, rained/un-drained, as well as whole or smashed.

Harmful clinical waste:

Expert as well as associated waste, arising from professional, nursing or similar methods and likewise waste
generated in facilities throughout the examination or therapy of individuals (biography threat).

Ran out medications, strong:

Waste medicines, medications and likewise medicines, containing delicate medicines.

Ended medications Iiquid:

Waste liquid pharmaceuticals, numerous kind liquid chemicals for treatment, clinical
oil, along with paraffin based xpired medications.

Ran out and/or contaminated fod:

Ruined fresh food or unusable MRE’s (Meal Ready for Consume – – – – completely dry food)

Onsite Training and also Assem Option for Industrial Incinerators

I. The prospective customers should includ 1a rate in their bargain for training in a central place (Goma or
Bukavu) approximately 15 workers in the procedure and maintenance of the
devices.

Smart Ash Incinerators

1. Size demand for the burners is that the gadget works together with a 55 gallon open ended up
steel drum.
2. The system ought to operate wit. no gas and also make use of just 120V or 220V electric energy for the blowers.
3. The system needs to can melting oil contaminated wastes as well as additionally clinical wastes with a moisture product of 0-15% J.
4. Each tool should certainly consist of 2 steel drums, to make sure that an extra drum is offered.

Spare Components Selection.
If there are any type of provider recommended extra components, that list in addition to price should certainly be consisted of as a choice in the bargain.


Nayu วัสดุป้องกันไฟฟ้าสถิตย์

2019-05-20 ความสำเร็จและ กรณี389 มุมมอง

Nayu วัสดุป้องกันไฟฟ้าสถิตย์

ชื่อโครงการ : โรงทำความสะอาดวัสดุป้องกันไฟฟ้าสถิตย์ Nayu ห้องอาบน้ำแอร์

แนะนำโครงการ : ออกแบบ ผลิต และติดตั้งโรงเรือนสะอาด 7 แห่ง

ระยะเวลาดำเนินการ: 2013.5




Nayu Anti-Static Materials (Tianjin) Co., Ltd. เป็นองค์กรที่ได้รับทุนสนับสนุนจากเกาหลีที่จดทะเบียนกับ Tianjin Administration for Industry and Commerce ที่อยู่สำนักงานตั้งอยู่ในเมือง Saida International Industrial City เขตพัฒนาเศรษฐกิจและเทคโนโลยี Xiqing ซึ่งเป็นศูนย์กลางทางเศรษฐกิจของ Bohai Rim เรามีผลิตภัณฑ์และความเชี่ยวชาญที่ดีที่สุด ทีมขายและเทคนิคของเราในกระบวนการพัฒนาบริษัทเราให้บริการลูกค้าด้วยผลิตภัณฑ์ที่ดีที่สุดการสนับสนุนด้านเทคนิคที่ดีและบริการหลังการขายที่ดี

URL เนื้อหาเพิ่มเติม: www.ecolead.cn โทร: 025-57138032

installation d'un système d'incinération jetable de déchets

installation d’un système jetable de déchets à l’aéroport, incinérateur avec brûleur fioul
Capacité 2 tonnes / jour, réservoir d’huile 300 l Pompe à huile 0.4Kw, brûleur 0.2Kw
Modèle: Série YD
Pays d’origine: ITALIE.- Incinérateur diesel.

– 25 kg / h. Il contiendra principalement du papier, du carton et de la nourriture, mais il incinérera également les déchets médicaux. L’incinérateur doit donc être en mesure de traiter les déchets organiques et dangereux.

– Pièces de rechange pour un an.Capacité de combustion: 400 kg / heure (le temps de combustion maximal est de 6 fois / jour)
Diamètre extérieur de la cheminée: pas plus de 400 mm
Puissance du ventilateur: ne doit pas dépasser 1,1 kW
Tension: 220V
Consommation d’huile: ne doit pas dépasser 14 kg / h
Largeur de la porte d’alimentation: pas moins de 1000x1300mm
Température d’incinération: 800 degrés ou plus
Émission:
CO- Ne doit pas dépasser 100 mg / m3
SO2- Ne doit pas dépasser 400 mg / m3
HF (fluorure d’hydrogène) – Ne doit pas dépasser 9 mg / m3
NO2 – Ne doit pas dépasser 500 mg / m3
Poussière de fumée: ne doit pas dépasser 100 mg / m3

– La conception doit empêcher tout rejet de substances polluantes dans le sol, les eaux de surface et les eaux souterraines.

– La zone de combustion doit atteindre au moins 860 degrés dans les conditions les plus défavorables avec au moins 6% d’oxygène. Puisqu’il traitera les déchets dangereux et organiques, la température doit atteindre au moins 1100 degrés pendant au moins 2 secondes.

– Les gaz de combustion doivent être refroidis à 200 degrés ou moins avant le traitement des gaz de combustion. L’équipement d’épuration des gaz de combustion doit être au moins un précipitateur électrostatique à deux champs / ESP, poussière <30 mgNm3.

– Efficacité thermique d’au moins 85%.

– Il doit être équipé d’un filtre pour réduire et contenir les polluants issus des déchets organiques et médicaux.

– Facile à utiliser pour les travailleurs presque non qualifiés.

Small Medical Office Waste Incinerators

Product Description

PLC( Programmable Logic Controller), Intelligent and Automatic operation.

Items/Model TS50(PLC)
Picture  
Burn Rate 50 kg/hour
Feed Capacity 100kg
Control Mode PLC
Combustion Chamber 560L
Internal Dimensions 100x80x70cm
Secondary Chamber 280L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.7Kw
Oil Consumption (kg/hour) 12.1–24
Gas Consumption (m3/hour) 9.9–26.1
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 70x55cm
Chimney 5Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800degree–1000degree
2nd. Chamber Temperature 1000degree-1200degree
Residency Time 2.0 Sec.
Gross Weight 4500kg
External Dimensions 230x130x155cm

Nanjing Clover Medical Technology Co., Ltd.. Is a leading waste incinerator maker in China. We are local manufacturer and one of the greatest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the planet, such as Medical Waste, Animal Incineration, refractory, refractory concrete incinerator petroleum and gas, refractory incinerator, rotary kiln incinerator layout, s. A. Incinerator company- fuel capacity sizing to incinerator, Pet cremation and other good wste. The potential from 10kgs/Hr. To 500kgs/Hr. Up to 6ton per day. Presentlywe provide different show for local customer requirements and layout upgraded incinerator with our leading technology. The upgraded design characteristic of our range of incinerators create them one of the most cost effective in the world.

dual chamber burner


Waste calorific worth: 4000KCAL/KG
Moisture Web content: 10-25%.
Small Ability: 50Kg/Hour set load.
Additional Chamber: 2 Secs @ 850degrees C
The main burning chamber must make certain very little separation temperature degree is not much less than 850 degrees C.

INSULATION.
Calcium Silicate.
Restricting Constant solution restriction 1000 degrees C.
Density 25mm

THROUGHPUT.
50kg/hour at a tiny calorific worth of 4,000 kcal/kg as well as an average bulk density of 120kg/MCubed for standard waste as well as 160kg/MCubed for medical care waste.All type of chemicals substances (Biocides) that made use of for Oil procedure sites (water base Exploration, oil operating centers for the corrosion as well as additionally others: The circumstances of the biocides are “WS-36, HAI-85M, SOFT DRINK ASH, DSMA, MICRO MATRIX, CALCIUM CARBONATE PENALTY, BARAKLEAN, GILSONITE, MIXED WASTE DIRT CHEMICALS, ZINC CARBONATE, CAUSTIC SODA, ENVIROTHIN, BARAZAN D,. etc) in addition to the products are solid and fluid.

2. In regards to the quantity of dropping the waste, possibly 200 – – – – 500 kg per human resources.

3. Our Operational time can be in Day in addition to can be during the night.

4. Can you please provide me the expenditure of device operated with Diesel as well as Gas.The primary burning chamber is the major structure of the heater, produced from light steel plate as well as tensed with rolled steel areas. It is brought from the flooring degree on a substantial steel assistance framework. Internally the covering is lined with calcium silicate insulation and additionally a warm face combination of incredibly duty brickwork or high strength castable.
The vital burning chamber must see to it minimum departure temperature level is very little less than 850 ° C
. One Hands-on Lots Incinerator comprising:.
·???????? Guidebook Loading door.
·???????? Horizontal strong fire place, refractory lined main combustion chamber. Approximate dimensions 800 mm dimensions x 2100mm long.
·???????? Complete sized bulk load/ash elimination door.
·???????? 1 off diesel-fired ignition heater– – temperature level managed. ·???????? 1 off shedding air supply fan in addition to distribution system, automated control.
·???????? High capacity additional burning chamber with residence time very little less than 2 secs @ >> 850 ° C. ·???????? 1 off diesel-fired afterburner– – temperature handled.
·???????? Control board– – automated operation.
e????? Temperature level sign key as well as likewise second chambers 0-1200 ° C.
e????? Refractory lined flanged smokeshaft to an elevation of 10M over ground degree


incinerator plant specification


1) Power Supply:
( a) Keys Supply:
( i) Singular Phase supply; 220– – 240V, 50Hz( ii) 3 Stage supply; 380– – 415V, 50Hz( iii) The power supply electrical outlet (sockets) for solitary stage supply system in the hospital is three pins as well as additionally adheres to BS1363.

(b) Change:( i) Keys modification is an usual concern, the performance requires to be affected by this problem a resistance of ± 15% or more in both the nominal voltage should certainly be permitted.
( ii) Keys Cut-off (black out) is a regular problem. Where required, Uninterrupted Power Supply (UPS) System should be consisted of to stay clear of damages of equipment as a result of sudden disruption in power supply.
( iii) There are spikes not necessarily from the secrets supply nonetheless results when specific plants or devices began.
( iv) Vendors must as a result validate to make certain that their power supply systems will not be affected by the above conditions.

2) Supply Of Water a) High quality: the mains supply is tough water. The supplier requires to check/modify their equipment with filters or descalers where required.
b) Anxiety: this varies and connected with frequent removed. Where needed, the company ought to consist of boosters or pumps to overcome this problem.
c) Where called for, representatives must contain water distillers

2-83 Location VI. Needs

3) Temperature degree: ambient temperature level varieties in between 21– – 450 C or even a lot more in inadequately aerated areas. The hottest month of the year is March. Environmental temperature level can be such that inferior rubber as well as also plastic items can easily melt or warped. Prospective buyers must make certain all items will certainly have the capability to endure such temperatures

4) Humidity: moisture is generally high concerning 65– – 90%. Electronic gadgets should be secured to prevent the impact of condensation.

5) Dirt: this is a significant concern specifically throughout the dry duration. Dust get in tools as well as congests filters. Additional safety and security needs to be provided where crucial along with where suitable extra filters offered to last not much less than 5 years continuous usage.

6) Vermin: these are additionally supplied as well as sometimes take part in equipment to chew cable tv along with pee on boards to create short circuit. This can be stopped by using vermin guard where required to prevent entry of such destructive pets.
7) The proposed tools has to adapt today ideal international standard such as ISO; CE; IEC, ANSI and/or BS

8) Language: a) All tags along with markings on the tools require to be in English language. b) All software program application programs in the suggested gadgets should remain in English language c) All handbooks need to remain in English language.

9) Each of the devices supplied requirement to be provided with client and additionally technological manuals. Guidelines on their use, storage space as well as also remedy must be clearly indicated in the handbooks and additionally where essential, on the tools.

10) Where ideal the following will use: a) Electrical Safety i) The tool needs to be supplied a line (power) cable of acceptable sturdiness, size, ampacity, and also top quality as well as additionally needs to be safeguarded with ideal stress and anxiety alleviations.
ii) The device ought to include, or the bidder or distributor have to provide, power plugs that are sufficient for the optimum voltage and also current of the device.
iii) The structure requires to be based as well as grounding resistance needs to not surpass 0.15 ohm.
iv) If the system is twin shielded, it ought to be so classified.
v) Electrical leak current from the structure of the gadget should not surpass 500µA per IEC 601-1 b) Effects of Fluids

Location VI. Needs 2-84

i) Individual as well as likewise operator safety and also safety and security as well as system efficiency require to not be detrimentally affected by liquid spills.
ii) If the system is influenced, it needs to fail safely.

c) Overcurrent Safety i) Loss of power to different other devices on the precise very same branch circuit as a result of internal equipment blunders need to be protected against by utilizing incorporates or breaker that are clearly labeled as well as easy to replace or reset.
Long-lasting markings near each fuse holder need to suggest fuse scores.
of the tiny line voltage of 220Volts.
ii) The system must not be harmed by voltages from -21% to +12.5% of the small line voltage of 220Volts.

e) Electromagnetic Disruption (EMI).
i) The tool’s performance should not be influenced by EMI discharged or carried out with the high-voltage line from one more tool.
ii) If the system is affected, it ought to fall short securely.

f) Alarms.
i) The device needs to have aesthetic or audible alarm to recommend chauffeurs of any type of kind of system mistake that might activate harmful or incorrect results.
ii) Audible and/or aesthetic indicators should certainly cause when the display reading gets to and stays at the security system limitation.
iii) All alarms have to be absolutely clarified in the chauffeur’s manual.

g) Audible Alarms.
i) Audible alarm systems need to be distinctive along with easily recognized.
ii) Distinct alarm systems should be made it possible for when the device is turned on (i.e., the default volume need to not be readied to OFF) as well as ought to be plainly distinct at any type of sort of amount setting.
iii) If the alarm system quantity is versatile, it needs to not be feasible to turn the quantity down so minimized that it is not more than likely to be listened to.
iv) Although an audible-alarm silence is acceptable, the alarm must repeat automatically if the problem is not treated.
v) If an alarm system is silenced, an aesthetic display ought to plainly suggest which alarm system is burdened.

h) Aesthetic Security system.
i) Visual security system should be basic to recognize.

2-85 Location VI. Demands

ii) The aesthetic alarm system needs to define to the trouble as well as continue to be on up until the alarm problem is taken care of; it needs to not be feasible to turn off the aesthetic alarm.

i) Structure and building Top-notch.
i) The system has to have no sharp edges.
ii) All external components ought to be firmly placed.
iii) The system ought to be secured along with supply suitable protection versus transferring as well as electrically stimulated elements.
iv) The system should certainly be well constructed with long lasting products to withstand common misuse and also cleansing.
v) Switches over, deals with, as well as various other controls must be designed for problems of hefty usage.
vi) Electrical wiring and likewise tubes should be well arranged in addition to packed, if ideal. vii) Mechanical, electric, along with pneumatic terminators, adapters, outlets, in addition to.
solder joints should be created to stop fluid infiltration, imprecise links, and also mismating of ideal in addition to combinings.
viii) Connections need to be risk-free to stand up to unintended disconnection as well as ought to protect sterility, when perfect.

j) Controls.
i) The controls (i.e., switches over, knobs, and so on) require to be noticeable in addition to simply established, and likewise their attributes have to be self-evident.
ii) Device design ought to prevent false impression of screen screens as well as likewise regulate arrangements.
iii) Buttons and additionally manages should certainly be secured versus unforeseen configuration adjustments (e.g., due to an individual cleaning versus the panel).
iv) Controls requires to be sealed versus infiltration of liquids.

k) Categorizing.
i) Labels as well as markings should certainly be clear and likewise readable.
ii) Labels and additionally markings must be resilient adequate to withstand normal cleansing as well as likewise normal wear.
iii) Correct care tales should be provided on the device.

l) Ease of Usage and upkeep.
i) The system has to be fundamental to find out to use, run, and additionally keep.
ii) The system needs to have abbreviated operating instructions consisted of on or with the unit (e.g., on a laminated card affixed to the device).
iii) The gadget needs to be simple to tidy, sterilize, and/or decontaminate, as ideal. iv) The device should be created for simple accessibility to functional components.

m) Unique maintenance tools, spare-parts along with consummables.
i) Where needed or needed, the carrier has to consist of any type of sort of special tools required for the upkeep of the suggested gadgets.
ii) Each devices ought to be given with the recommended spare-parts

Location VI. Needs 2-86

needed for precautionary maintenance for 5 years and also where needed contain supply of encouraged spare-parts for rehabilitative maintenance.
n) Training.
i) The vendor is required to supply ample training on each tools on the suitable use as well as procedure of the tools.
ii) Likewise, suppliers are required to provide adequate vendor’s training on the installation as well as likewise maintenance( both preventative and restorative).
o) Product packaging and also Storage space Room Troubles of Devices.
i) The tools as well as components ought to take on temperature as well as also dampness extremes more than likely to be experienced throughout storage space as well as likewise transport.
ii) The manufacturer must recommend treatments for storage of the tools.

6) Vermin: these are additionally offered as well as sometimes participate in equipment to eat cable televisions as well as pee on boards to produce brief circuit.


Incinérateur de déchets médicaux 30kgs modèle TS30 PLC

Incinérateur de déchets médicaux de 30 kg par heure (en moyenne), conception double
chambres de combustion (chambre primaire et chambre secondaire),
chambre de filtre à fumée, PLC auto. système de contrôle, 0,33 m3 (330 litres)
chambre de combustion primaire , brûleur à mazout ou à gaz en italie. pour petit
traitement des déchets médicaux hospitaliers.
Acheter un incinérateur de déchets, trouver hiclover

Articles / modèle

Automate TS30

Principe

Incinération des déchets

Taux de brûlure

30kgs / heure en moyenne

Type de carburant

Gazole / gaz naturel

Mode de contrôle

Panneau de contrôleur logique programmable (PLC)

Chambre de combustion primaire

0,33 m 3

Dimensions internes (primaire)

750x750x600 millimètre

Chambre de combustion secondaire

0,18 m 3

Dimensions internes (secondaires)

400 x 750 x 600 mm

Chambre de filtre à fumée

Oui

Mode d’alimentation

Manuel

Tension

220V

Pouvoir

0,5 Kw

Consommation d’essence

10,2―20,0 kg / heure

Consommation de gaz

9,8―20,0 m 3 / heure

Moniteur de température

Affichage numérique

Protection de la température

Contrôle PLC

Réglage de l’heure

Contrôle PLC, 0-120 minutes

Cuve à mazout

100 litres

Porte d’alimentation des déchets

550x500mm

Cheminée

5,0 mètres

Type de cheminée

Acier inoxydable

Température de la chambre primaire

800 ℃ –1000 ℃

Température de la chambre secondaire

1000 ℃ -1200 ℃

Temps de résidence

2,0 sec.

Poids brut

3000 kg

Dimensions extérieures

1750x1200x1400 millimètre


Incinérateurs de déchets
Incinérateur de déchets médicaux
Crémation d’animaux de compagnie
Déchets solides   Incinérateur
Environnement médical

Tél: + 86-25-8461 0201
Mobile: + 86-13813931455 (whatsapp / wechat)
Site Web: www.hiclover.com
E-mail: [email protected]
E-mail: [email protected]
Nanjing Clover Medical Technology Co., Ltd.

animal cremation

Technical Specifications of External SHREDDER Controls:

  • Pre-programmed PLC controlled
  • Password activated and reversal history indication
  • Motor starter with overload protection
  • Automatic instantaneous stop on hard object in shredder bed
  • Automatic heavy cutting load reversal and re-try , up to three times
  • Control housing Nema type 12

 

Cutting Hardwires:

  • Chamber Dimensions(WxLxH): approx 33 c m x 38 cm x 25cm
  • Number of knives: Approx 18 or to suit customer needs
  • Knife Thickness: Approx 18mm or to suit customer needs
  • Knife Diameter: Approx 16cm or to suit customer needs
  • Tecth per Knife : minimum 3
  • Number of Shafts: 2 ie double shaft shredder

 

Drive of the shredder:

  • Must be motor driven
  • Motor Horsepower : approx, 10 HP
  • Motor RPM: minimum 1750
  • Speed Reduction: 60:1
  • Generated Torque; min 40 Nm or 350 lbs/in
  • Gearbox: should be parallel shaft
  • Shock protection: Rubber mount torque arm
  • Power : 220vac, 1ph or 400 VAC, 3 ph or suit customer needs

 

Ancillaries to be included:

  • Sherdder stand, fabricated from 3” sq. steel tube, standard height 30 inches
  • Shredder hopper , fabricated form 16 gauge steel, with optional switched hopper lid.

 

(E) Features & Technical Specification of Conveyer:

To carry processed waste from vessel to shredder

 

Control:

  • Motor starter overload protection
  • Control housing Nema Type 12
  • Safety pull stops along both sides of conveyor

 

Ancillaries:

  • Conveyor stand , fabricated from 2” sq. steel tube
  • Raised sidewalls fabricated form 16 gauge steel

 

dimension:

  • Over-all length: between 20-25 feet or appropriate length depending on the installation requirement.
  • Over-all width: between 24-30 inch
  • over-all (without including stand) : between 12-14 inch
  • Available inclines: 0-40 degrees

 

Belt:

  • Belt Speed: 75 fi/min
  • Dam spacing; approx, 16 inch

 

Drive:

  • Motor driven
  • Horsepower: Approx .075
  • Motor RPM: approx.60
  • Electrical power input: 220 vac. 1ph or 400 VAC, 3 ph or to suit customer needs.

 

(F) Technical Specification of tipper features:

  • It is to be designed to allow for easy bin positioning under the door to unload processed waste and easy

inaneuverapility for lifting and tipping the waste into the shredder hopper.

  • Equipment with 2 bins to accommodate processed waste loads to be loaded into the shredder and shredded waste to be

transported to the disposal bin.

  • Frame: Rugged heavy duty frame constructed of formed and welded steel formed and welded steel for extra strength.
  • Mast: Fabricated with channel steel for greater strength and dependability. Open structure design complete with

safety cage to offer greater visibility

  • Lifting Chains: Must be dual lifting chain of roller style & must meet safety factor at least 6:1
  • Hydraulic system: durable cylinder with a chrome plated ram and a relief valve for overload protection
  • Forks: Heavy duty approx 4.0” wide x 42” long fixed forks.
  • Platform; solid steel
  • Battery: A heavy duty 12 volt, 125 amps/hour industrial strength battery.
  • Overload protection plugs into any 220 VAC outlet.
  • Steering: A pallet truck style steer handle for steering and approx. 4” phenolic wheels with roller bearings located

in the straddle legs.

  • Brake: A hand controlled floor lock brake that secures the unit in place.

 

Specifications:

  • Load capacity; Approx 1500 lbs
  • load centre: Approx 24 inch
  • Raised fork height: to suit customer needs
  • Overall must height: to suit customer needs
  • Lowered height: minimum 4.0 inch
  • Fixed fork width: approx 7 inch
  • Fork length : approx 42 inch
  • Platform of approx.25”x25”
  • overall width approx 25 inch
  • castors: approx 5 inch phenolic
  • Front wheel : approx 4 inch phenolic

Horno de cremación utilizado para mascotas

Descripción del producto

Nanjing Clover Medical Technology Co., Ltd. es un fabricante líder de incineradores de desechos en China. Somos fabricantes locales y uno de los mayores exportadores de China. El equipo técnico de incineración pirolítica es el principal tratamiento de desechos en todo el mundo, para desechos médicos, incineración de animales, cremación de mascotas y otros wste sólidos. La capacidad de 10kgs / Hr. Hasta 500kgs / Hr., Hasta 6ton por día. Actualmente, incinerador diesel de 10 kg por hora, incinerador diesel de doble cámara, incinerador doméstico, incinerador de doble cámara de 100 kg por hora, fabricantes con precios, suministramos diferentes series para los requisitos del cliente local y diseñamos incineradores actualizados con nuestra tecnología líder. La característica de diseño actualizado de nuestra gama de incineradores los convierte en uno de los más rentables del mundo.

Una velocidad de quemado del crematorio animal modelo de 20 a 400 kg por hora. Cámara de combustión resistente y traje para cremación de animales grandes.

Cámara secundaria y cámara de mezcla y combustión. Tiempo de residencia 2,0 seg. En cámara de postcombustión. Prácticamente libre de humo y olor.

Cámara de filtro de humo con ladrillo de filtro, prácticamente libre de humo y olor después de la combustión.

Quemador de gas o aceite original de Italia, calidad confiable. Es adecuado para gasoil, gas natural, gas LPG.

Guía del usuario, documento completo de instalación y funcionamiento para el cliente.

Artículos Especificación
Modelo A360 / A600 / A900 / A1200 / A1500 / A2400 / A4000 / A5500
Lista de productos principal Cámara de combustión primaria
Cámara de combustión secundaria
Mezclar la cámara de combustión
Cámara de filtro de humo
Caso de control común del incinerador
Chimenea de acero inoxidable
Quemador de gasoil / gas Italia: 02 unidades
Tanque de aceite (si es combustible de aceite)