The temperature is over the minimum and under the maximum required temperature (e.g 1150?C) of the thermal
reactor (partial load).
When switching off, only the solenoid valve for the fuel supply closes, the burner fan stays on to cool and protect the
burner head.
The reactor burner shall be modulating burner with pre-ventilation working on the principle of an oil pressure atomizer
with return nozzle for diesel oil, consisting of:
– Fan housing with high-powered fan and cover
– Electric motor
– Oil pressure pump with built-in oil pressure controller
– Burner nozzle rod with return nozzle and baffle plate
– Coupled control with servomotor, rate controller, regulating segment and air valves
– Electromagnetic shut-off dampers
– Burner tube with flame pot, burner connection and insulation flange
– Electrical high voltage ignition with ignition transformer and ignition electrodes
In the control panel:
– Oil firing sequence control automation relay.
capacity – 50 Kg
Burn rate – 20 Kg/h
maximum Temperature – 1000C
Operating Energy – Diesel
Ignition method –
Combustion chambers – 2
Insulation – refractory Lining
No of burners – 2
Loading Method – Front load with safety latch
Chimney – Heavy duty stainless steel
Control – Burner control
Thermostat control
Timer control
Fan timer control
Instrumentation -4 Digit temperature display
Ash removal – Separate ash removal door
Fuel consumption per Kg –
Automatic & simple to operate control pannel –
3 mm steel casing & fully insulation
Dense refractory concrete lining rated to 1400 degree to C
safety chute for easy loading –
SS Flue as standard –
Heat recovery option –
Easy onsite Installation –