portable incinerator manufacturers

Tanque

Capacidade mínima: 500L

Provido de estrutura de suporte

Válvulas

Indicador de nível de tanque

Funil

Filtro de impurezas na boca do tanque

 

 

comprising of, as a minimum, electronic ignition and all necessary interlocks and safety devices to provide safe

 

operation. The chamber and burner shall be designed to maintain a minimum combustion temperature of at least

 

930 to 980 C (1700 to 1800 F), but shall not to exceed 1150 C (2100 F). The ash-removal system shall consist of, as

 

a minimum, the direct manual removal into a dry

 

Cyclone air filters shall be provided to remove the larger particulates. Cyclone air separators may be provided with

 

powered fans to increase the velocity of the gases inside the cyclone to improve the collection efficiency for smaller

 

particles.

 

5.16.2 MEDICAL WASTE INCINERATORS

 

Medical waste incinerators shall be specifically designed by the manufacturer to dispose of all medical wastes. All

units shall be designed for 8 hours

 

per day of continuous operation and be rated in quantity per hour (i.e. kg/hr or lbs/hr).

 

Incinerator loading or charging of medical waste shall be batched-fed manually.

 

Primary combustion chamber shall be the stationary fixed-hearth (or kiln), multiple-chamber, retort type or larger

 

capacity rotary-hearth (or kiln) type. Burner and combustion air controls shall be fully automatic comprising of, as a

 

minimum, electronic ignition and all necessary interlocks and safety devices to provide safe operation. The