Specifications for Double Chamber Incinerator:
Primary Combustion
・ The primary combustion chamber shall be accepted as the primary combustion zone.
・ The minimum combustion temperature of the primary chamber shall not be less than 800 degrees c
Secondary Combustion
・ The residence time in the secondary chamber shall not be less than 2 seconds
・ The gas temperature as measured against the inside wall in the secondary chamber ,not in the flame zone shall not be less than as indicated in Lot 1-7
・ Both the primary and secondary temperatures shall be maintained until all the waste has been completely combusted
Chimney
・ The chimney shall have a minimum height of 4 metres above ground level
・ The minimum exit velocity of the emissions shall not be less than 10metres/second
Temperature Warnings
・ An audible and/or visible alarm to warn the operator when the secondary temperature drops to below the required temperature
General
・ Control box can be detached and mounted on separate stand of atleast 1.5metres from the incinerator at approximately 1.6 metre height
・ CE compliant or equivalent for incinerators of this size and model
・ Drawings and photos for the offered lots
・ 1 year spare parts,fuel tanks and 10metre hose to come standard with every incinerator
Specifications for Mobile Incinerator Units
Trailer mounted mobile incinerator units suitable for the following applications
・ Medical waste
・ Domestic waste
・ Industrial waste
・ Animal cadavers