Blog

Medical Waste Incinerators for Clinics and Small Hospitals

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: [email protected]
Email: [email protected]

Nanjing Clover Medical Technology Co.,Ltd.

Item Serie No. Part Name
Packing List 1# Incinerator Mainbody
2# Oil Tank(Deposit)
3# Oil Tank(Daily)
4# Chimney(Vertical,High Temperature)
5# Chimney(Horizontal,High Temperature)
6# Wet Scrubber
7# Chimney(S shape)
8# Chimney(Below)
9# Chimney(Top)

Hospital Incinerators for Medical Waste Destruction

SN  Item Specification
1 Model TS100
2 Burning Rate Ave.50-100Kgs/Hour
3 Feeding Capacity Ave.200Kgs/Feeding
4 Primary Chamber 1000 Liters
5 Secondary Chamber 540 Liters
6 Chimney Yes
7 Wet Scrubber Yes
8 Wet Scrubber Parameter Dia. 100cm Hight 2500cm
9 Feeding Model Manual
10 Power 380V 3P 50Hz
11 Power 6.0 Kw
12 Fuel Type Diesel Oil
13 Burner Italy
14 Oil Consumption (Diesel Oil) Average 20.4 Kgs/Hour
15 Internal Dimensions Primary Chamber 120 x 100 x 90 cm
16 External Dimensions (Main Body) 270 x 190 x 170cm
17 Temperature Monitor Yes
18 Oil Tank (Daily) 1.8M3
19 Oil Tank(Deposit) Parameter 10M3, Dia. 200cm Length 3500cm
20 Feeding Door 80 x 60cm
21 Chimney 6.0 M
22 Chimney Material S.Steel
23 Weight Ave.8500Kgs
24 1st. Chamber Temperature 800℃–1000℃
25 2nd. Chamber Temperature 1000℃-1200℃
26 Residency Time 2Sec.

2020-07-27

Medical Waste Incinerators for Clinics and Small Hospitals

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: [email protected]
Email: [email protected]

Nanjing Clover Medical Technology Co.,Ltd.

Item Serie No. Part Name
Packing List 1# Incinerator Mainbody
2# Oil Tank(Deposit)
3# Oil Tank(Daily)
4# Chimney(Vertical,High Temperature)
5# Chimney(Horizontal,High Temperature)
6# Wet Scrubber
7# Chimney(S shape)
8# Chimney(Below)
9# Chimney(Top)

Hospital Incinerators for Medical Waste Destruction

SN  Item Specification
1 Model TS100
2 Burning Rate Ave.50-100Kgs/Hour
3 Feeding Capacity Ave.200Kgs/Feeding
4 Primary Chamber 1000 Liters
5 Secondary Chamber 540 Liters
6 Chimney Yes
7 Wet Scrubber Yes
8 Wet Scrubber Parameter Dia. 100cm Hight 2500cm
9 Feeding Model Manual
10 Power 380V 3P 50Hz
11 Power 6.0 Kw
12 Fuel Type Diesel Oil
13 Burner Italy
14 Oil Consumption (Diesel Oil) Average 20.4 Kgs/Hour
15 Internal Dimensions Primary Chamber 120 x 100 x 90 cm
16 External Dimensions (Main Body) 270 x 190 x 170cm
17 Temperature Monitor Yes
18 Oil Tank (Daily) 1.8M3
19 Oil Tank(Deposit) Parameter 10M3, Dia. 200cm Length 3500cm
20 Feeding Door 80 x 60cm
21 Chimney 6.0 M
22 Chimney Material S.Steel
23 Weight Ave.8500Kgs
24 1st. Chamber Temperature 800℃–1000℃
25 2nd. Chamber Temperature 1000℃-1200℃
26 Residency Time 2Sec.

2020-07-27

Small Medical Waste Incinerator 2 combustion chambers with scrubber

Small Medical Waste Incinerator 2 combustion chamber with scrubber for Virus medical waste

On-Site Incineration Solution‎

Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities,
and medical research facilities. These wastes include both infectious (“red bag”)
medical wastes as well as non-infectious, general housekeeping wastes.

Items/Model TS30(PLC)
Picture

Burn Rate Average 20-30 kg/hour
Feed Capacity Average 60kg per feeding
Control Mode PLC(Programmable Logic Controller Incinerator)
Combustion Chamber 330L
Internal Dimensions 75x75x60cm
Secondary Chamber 180L
Smoke Filter Chamber Yes
Feed Mode Manual Feeding
Voltage 220V
Power 0.5Kw
Oil Consumption (kg/hour) Average 13.3
Gas Consumption (N.G, m3n/Hour) Average 16
Gas Consumption (L.P.G, m3n/Hour) Average 11.7
Temperature Monitor Four Digital Display
Temperature Protection Yes
Oil Tank 100L or More(Optional)
Feed Door 55x50cm
Chimney 5Meter or More(Optional)
Chimney Type Stainless Steel
1st. Chamber Temperature 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Gross Weight 4000kg
External Dimensions 175x120x140cm

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: [email protected]
Email: [email protected]

Nanjing Clover Medical Technology Co.,Ltd.

2020-07-27

Small Medical Waste Incinerator 2 combustion chambers with scrubber

Small Medical Waste Incinerator 2 combustion chamber with scrubber for Virus medical waste

On-Site Incineration Solution‎

Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities,
and medical research facilities. These wastes include both infectious (“red bag”)
medical wastes as well as non-infectious, general housekeeping wastes.

Items/Model TS30(PLC)
Picture

Burn Rate Average 20-30 kg/hour
Feed Capacity Average 60kg per feeding
Control Mode PLC(Programmable Logic Controller Incinerator)
Combustion Chamber 330L
Internal Dimensions 75x75x60cm
Secondary Chamber 180L
Smoke Filter Chamber Yes
Feed Mode Manual Feeding
Voltage 220V
Power 0.5Kw
Oil Consumption (kg/hour) Average 13.3
Gas Consumption (N.G, m3n/Hour) Average 16
Gas Consumption (L.P.G, m3n/Hour) Average 11.7
Temperature Monitor Four Digital Display
Temperature Protection Yes
Oil Tank 100L or More(Optional)
Feed Door 55x50cm
Chimney 5Meter or More(Optional)
Chimney Type Stainless Steel
1st. Chamber Temperature 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Gross Weight 4000kg
External Dimensions 175x120x140cm

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: [email protected]
Email: [email protected]

Nanjing Clover Medical Technology Co.,Ltd.

2020-07-27

HICLOVER Waste Incinerator 10-500kgs/Hr.Double Combustion Chambers

HICLOVER Incinerator/Parts Range Main Feature
Medical Waste Incinerators HICLOVER 10-500kgs/Hr.Double Combustion Chambers
Single Combustion Chamber Small, Cheap,10-20kgs/Hr.
Three Combustion Chambers(Optional) 3 Chambers for high risk waste
Pet Cremation Equipment For Pet(small/big) Cremation Business
Animal Incineration Equipment For other animal incineration
General Waste Incinerator For MSW
Mobile Incinerator(Optional) Small-Middle scale, mobile function by

1. )Wheel

2.)DC-Power Trolley

3.)Trailer

4.)Containerized

Wet Scrubber for Smoke Filter(Optional) 1. ) 1 Section Wet Scrubber

2.)3 Sections Wet Scrubber

1 Section Wet Scrubber S.S304 Cooling Spray tower
3 Sections Wet Scrubber 1.)S.S304 Cooling Spray tower

2.)S.S304 Dust Scrubber

3.) S.S304 Fog and Water Separator

Feeding Door 1.) Front/Side Manual Loading

2.) Top Feeding Door(Optional)

3.) Auto. Feeding Door(Optional)

3rd Combustion Chamber(Optional)
Stainless Steel Main Body(Optional) S.S201 or S.S304
Control Model 1.) Electric control box(Semi-automatic)

2.) PLC Auto.control box(Automatic)

Light Weight Upgrade(Optional)
W2E(Waste to Energy)(Optional) Hot Water(Non-drinking water)
Fuel Burner Italy Baltur Brand

4.) Both D.O and N.G/LPG(not 2in1 burner, exchange burner type)

Temperature Thermocouple 1.) K Type,Stainless Steel 1300(Standard)

2.) K Type,Corundum 1300(Optional)

3.) S Type,Platinum Rhodium 1600(Optional)

Control Case Material 1.) Steel (Standard)

2.) Stailess Steel(Optional)

Chimney/Stack 1.) Stailess Steel (Standard)

2.) Steel(Optional)

3.)Length(Optional)

4.)Thickness(Optional)

Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Oil Tank 200L 300L 500L 500L
Feed Door 80x60cm 80x60cm
Chimney 10Meter 10Meter 14Meter 14Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 6000kg 8500kg 11000kg 16000kg
External Dimensions 260x150x180cm 300x160x190cm 400x210x300cm 450x210x300cm

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: [email protected]
Email: [email protected]

Nanjing Clover Medical Technology Co.,Ltd.

2020-07-27

Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste

Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste.

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: [email protected]
Email: [email protected]

Nanjing Clover Medical Technology Co.,Ltd.

2020-07-21

Smallest Waste Incinerator for PPE waste face mask glove waste

Smallest Waste Incinerator for PPE waste face mask glove waste

Ave 400kgs for shipping, 1 chamber, 1 burner ,1 air fan, 1 control box, 1.5Meter chimney

ave 10kgs per hour, 100kgs per day(10hr/day working)

Equipment Technical Specifications
Model YD-10
Picture

Feed Capacity Average 20 kgs per feeding
Burning Rate Average 10 kgs per hour
Burning Time per Feed 2 hours
Voltage 220V
Power 0.5Kw
Fuel Diesel oil
Burner Italy Burner
Feed Mode Manual
Fuel consumption (Oil) Ave. 4.2 Kgs/Hour
External Dimensions Dia.100 x 130cm (mainbody)
Internal Dimensions Dia.50 x 80cm
Waste combustion chamber 200Liters
Oil Tank Capacity 100 Liters
Door Opening 35 x 35cm
Chimney 1.5M
Gross Weight Ave.400kgs
Chamber Material Refractory Concrete&Ceramic Fiber
Max. Heat Value 42,000Kcal/Hr.
Operation Technical Specifications
Chamber temperature 8000C -10000C
Chamber Anti-Rate 14000C
Burning efficiency >98%
Waste Lower Calorific Power 3000Kcal

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: [email protected]
Email: [email protected]

Nanjing Clover Medical Technology Co.,Ltd.

2020-07-17

Incinerator YD-150 with Stainless Steel Wet scrubber-Cooling Spray tower

Model YD-150
Burning Rate Average 150 kgs/hour
Feed Capacity Average 300 kgs/feeding
Primary Combustion Chamber 1500 Liters
Secondary Combustion Chamber 500 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 1.03Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 17–36 kg/hour
Gas Consumption (Natural Gas) 11–36.7 m3/hour
Internal Dimensions 150 x 100 x 96cm (primary chamber)
External Dimensions 240 x 170 x 380cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 300 Liters
Door Opening 59 x 81cm
Chimney Length 10.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 7500 kgs

before start the 2nd burner, full close all air valve on the 1st chamber. other operation keep same.

reason: at the first 10-20 min burnning the plactic waste, deflagration combustion in the chamber.

after 10-20 min, gradually increase air injection by air valve on the 1st chamber.

meanwhile, proposal 20-30 min burnning of the 1st chamber, stop the 1st burner(stop fire only, the fan inside the burner
still working), let the plastic burn itself(Spontaneous combustion) to save diesel oil.

a small waste to energy project to turn municipal solid waste

Model YD-150
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix-Combustion Chamber
Smoke Filter Chamber(Dry Scrubber)
Incinerator Control Case(PLC Auto.Type)
Chimney:10.0Meters

*(upgrade to Stainless Steel, free cost)

Italy oil/gas burner: 02 sets
Oil Tank (if oil fuel): 300Liters
Optional Part:

Stainless Steel Wet scrubber(Cooling Spray tower)

into electricity. The project is to cater for a local council with a population of around 60,000 people and will serve as a

pilot project. If project is successful than other such plants will be installed in other towns and villages. The villages

will all cater for the MSW in their locality instead of a central large incineration plant to cate for the whole county.for a 7 ton per

hour plant on turn-key basis with your best price and delivery including full technical specifications, literature, drawings

and best export price.

Provided you can offer a good solution there is a chance of selling many more such plants for the local councils of the same

country, so this is an excellent chance for you to join forces with our company for market penetration with your products in

Europe.

1. TS100 model with dry scrubber system
2. YD150 with a wet scrubber system

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: [email protected]
Email: [email protected]

Nanjing Clover Medical Technology Co.,Ltd.

2020-07-14

Incinerator burn medical and bio waste

Incinerator burn medical and bio waste

Items/Model TS100(PLC)
Picture

Principle Medical Waste Incineration Treatment
Burn Rate Average 100 kg/hour
Control Mode PLC(Programmable Logic Controller Incinerator)
Combustion Chamber 1200L
Internal Dimensions 120x100x100cm
Secondary Chamber 600L
Smoke Filter Chamber Yes(Dry Scrubber)
Feed Mode Manual
Voltage 220V/380V
Power 0.7Kw
Oil Consumption (kg/hour) average 20.4
Gas Consumption (m3/hour) ***
Temperature Monitor Digital Display
Temperature Protection Yes
Oil Tank 200L
Feed Door 80x60cm
Chimney 10Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Gross Weight 6000kg
External Dimensions 260x150x180cm

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel: +86-25-8461 0201
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/
Email: [email protected]
Email: [email protected]

Nanjing Clover Medical Technology Co.,Ltd.

2020-07-14