Burner YD-500 for Vietnam


We finish this project in year 2010 to 2011 and also distribution to Hochiminh port, Vietnam with 1×× 40′ feet open leading full container.

Items/Model YD-500
Burning Rate (kgs/Hour) 500 kgs/Hr.
Feed Capacity (kgs) 800 kgs
Equipment Weight 13000 kgs
Primary Chamber (Liters) 4000
Secondary Chamber (Liters) 1500
External Dimensions (cm) 320x220x460
Internal Dimensions (cm) 257x147x108
Oil Tank(Liters) 500
Door Opening (cm) 108 x 128
Chimney (M) 14
Chimney Type Stainless Steel
Secondary Chamber  YES
Mix-Combustion Chamber YES
Smoke Filter Chamber YES
Combustion Fuel Oil/Gas
Residency Time 2.0 Sec.
Temperature Monitoring YES
1st. Chmaber Temperature 800℃–1000℃
2nd. Chmaber Temperature 1000℃-1200℃

Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


Biological Waste Incinerators

Basic Info.

Export Markets:Global

Product Description

Key Features:  * All versions with Dual combustion chamber.  *according to order  * High fever, long lifetime of incinerator.  * Free or minimum installation onsite.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton daily.  *according to order  New Design for pet animal cremation business.  * One year warranty on incinerator and components in stock.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

установка для сжигания медицинских отходов китай

Установка для сжигания медицинских отходов, Китай, Проектирование, поставка и производство на заводе одной установки для сжигания медицинских / общих отходов Surefire Manual Load TS50 / 1, как указано ниже: –

· Тип отходов: смешанные типы отходов o, 1, 2, 3 и 4, опасные для больниц / клинических учреждений.

· Плотность отходов: от 125 до 350 кг / м3

· CV отходов: 4000 ккал / кг

· Содержание влаги: 10-25%

· Расчетный остаток золы: 5-10%

· Номинальная производительность: загрузка партии 30 кг / час.

· Вторичная камера: 0,5 секунды при 850oC
· Компактный лабораторный стиль

· Две камеры сгорания

· Экологически чистый

· До 50 кг отходов / час

· Для животных

Catálogo Pdf Incinerador Capacidad 100kg

Información básica.

No. de modelo: tecnología de tratamiento de residuos médicos sin incineración
Mercados de exportación: Global

Descripción del producto

Características principales:
* Todos los modelos con doble cámara de combustión.
* Chimenea / chimenea de acero inoxidable, larga vida útil. * según pedido
* Alta temperatura, larga vida útil del incinerador.
* Instalación gratuita o mínima en obra.
* Alta velocidad de combustión, de 10 kg a 500 kg por hora, hasta 6 toneladas por día.
* Plano de control PLC. * según pedido
* Nuevo diseño para el negocio de cremación de animales de compañía.
* Garantía de un año en incinerador y piezas en stock.

Ámbito de aplicación:
1. Hospital y clínica: Residuos Iátricos, Residuos Infecciosos, Vendajes, Biorresiduos, Medicina.
2. Matadero y hospital y granja de mascotas: animal muerto, biorresiduos.
3. Comunidad, puerto y estación marítima: residuos sólidos urbanos, etc.
4. Laboratorios, ubicaciones remotas, operaciones de socorro en casos de desastre, cremación de animales

Nanjing Clover Medical Technology Co., Ltd. es un fabricante líder de incineradores de desechos en China. Somos fabricantes locales y uno de los mayores exportadores de China. El equipo técnico del incinerador pirolítico es el principal tratamiento de desechos en todo el mundo, para desechos médicos, cómo construir un incinerador de gas LPG, cómo construir incineradores portátiles a pequeña escala, cómo comprar un crematorio para mascotas, fabricantes, cómo diseñar y construir un incinerador de desechos médicos. , Incineración de animales, cremación de mascotas y otros sólidos sólidos. La capacidad de 10kgs / Hr. Hasta 500kgs / Hr., Hasta 6ton por día. Actualmente, suministramos diferentes series para los requisitos de los clientes locales y diseñamos un incinerador actualizado con nuestra tecnología líder. La característica de diseño actualizado de nuestra gama de incineradores los convierte en uno de los más rentables del mundo.

Artículos / Modelo TS10 (PLC) TS20 (PLC) TS30 (PLC) TS50 (PLC) TS100 (PLC)
Velocidad de combustión 10 kg / hora 20 kg / hora 30 kg / hora 50 kg / hora 100 kg / hora
Capacidad de alimentación 20 kg 40 kg 60kg 100 kg 200 kilogramos
Modo de control SOCIEDAD ANÓNIMA SOCIEDAD ANÓNIMA SOCIEDAD ANÓNIMA SOCIEDAD ANÓNIMA SOCIEDAD ANÓNIMA
Cámara de combustión 100L 210L 330L 560L 1200L
Dimensiones internas Los 50x50x40cm Los 65x65x50cm Los 75x75x60cm El 100x80x70cm El 120x100x100cm
Cámara secundaria 50L 110L 180L 280L 600L
Cámara de filtro de humo sí sí sí sí sí
Modo de alimentación Manual Manual Manual Manual Manual
Voltaje 220 V 220 V 220 V 220 V 220 V
Energía 0,5 Kw 0,5 Kw 0,5 Kw 0,7 kilovatios 0,7 kilovatios
Consumo de aceite (kg / hora) 5,4-12,6 7,8–16,3 10.2-20 12.1-24 14-28
Consumo de gas (m3 / hora) 6.2-11.4 8-15,7 9,8-20 9,9-26,1 10–32,2
Monitor de temperatura sí sí sí sí sí
Protección de temperatura sí sí sí sí sí
Tanque de aceite 100L 100L 100L 100L 200L
Puerta de alimentación Los 30x30cm Los 45x40cm Los 55x50cm Los 70x55cm Los 80x60cm
Chimenea 3 metros 3 metros 5 metros 5 metros 10 metros
Tipo de chimenea Acero inoxidable Acero inoxidable Acero inoxidable Acero inoxidable Acero inoxidable
Tiempo de residencia 2,0 seg. 2,0 seg. 2,0 seg. 2,0 seg. 2,0 seg.
Peso bruto 1500 kg 2200 kg 3000 kg 4500kg 6000 kg
Dimensiones externas El 140x90x120cm El 160x110x130cm El 175x120x140cm Los 230x130x155cm Los 260x150x180cm

TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals in Kenya

TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals

 

INTRODUCTION

  • All the incinerators to be supplied and installed must meet the Government of Kenya waste Management Regulation 2006 in particular 3rdschedule regulation (26, 47) pertaining classification, standards, criteria, and procedure for installing/operating incinerators as authored by the National Environmental Management and Coordination (waste management) regulation 2006, legal notice No. 121 of 29th September 2006
  • The capacity of the incinerator required should be to the specifications with a capacity to burn 100kgs/Hr
  • The incinerator shall be run on a 3-phase power supply (mains)
  • For the technical evaluation, not only the treatment plant but the entire system will be considered.  It will be the responsibility of the Bidder to supply a full system, including all eventually additionally necessary secondary systems and additional equipment.
  • The system offered shall be designed to operate normally under the conditions of the purchaser’s country. The conditions include Power Supply, Climate, Temperature, Humidity, etc.
  • The Bidder must provide a warranty for one year.
  • All text, parameter etc. on all control operating interfaces as well as on information displays and on print-outs shall be in English language.
  • The Bidder is responsible for all permits and approvals for importation. The Bidder shall provide all the necessary documentation in order to facilitate the legal requirements for the installation and putting into use of the equipment.
  • Period of Execution is 90 days from contract signature for delivery to site and completion of all verification operations required for the issuance of provisional acceptance.
  • Representatives of the Contracting Authority and the Beneficiary, together with the Bidder’s representative, shall carry out the controls, testing and initial approval for provisional and final acceptance as.  The provisional and final acceptance shall take place at the final destination.
  • After-Sales Service: The Bidder is required to ensure that a maintenance, service and repair centre, which is authorised by the Manufacturer, and which is able to rapidly supply genuine spare parts and consumables recommended by the Manufacturer is available throughout the one year warranty period. In fulfillment of this requirement with their offer Bidders must submit a statement signed by a representative of the manufacturer:
    • Providing the name and address of its authorised maintenance, service and repair centre,
    • Confirming that this authorised maintenance, service and repair centre is able to rapidly supply genuine spare parts and the consumables recommended by the Manufacturer; and

 

  • The Bidder will be responsible to deliver and install all to be supplied equipment at to be set up waste handling areas in the Republic of Kenya. The Bidder shall deliver a time schedule over the complete construction and assembling period. The delivery and installation time must be agreed between bidders, target Hospital and the Contracting Authority. The treatment plant must arrive pre-assembled. The Bidder shall ensure that all parts of the plant transported by sea shall not be shipped as “deck cargo”.

 

  • It is expected that the Bidder cooperates closely with the contractor for the new waste handling building/area and will make available all needed technical information, drawing, etc. to the contractor.

 

  • The Bidder shall supply and install the incinerator with the following attached specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

           
TECHNICAL INCINERATORS SPECIFICATIONS FOR EAPHLNP
           
ITEM DESCRIPTION UNIT QTY RATE KSHS.
           
  Incinerator        
  To supply and install the following    2NO.    
  Hospital Incinerators to Nema standards        
  The following are the incinerator specifications :-        
A Ø      Waste type:      Mixed type 0,1,2,3 & 4 hospital/clinical bio hazard waste        
  Ø      Waste density:   125 to 350Kg/M³        
  Ø      Waste CV:        4000 KCAL/Kg        
  Ø      Moisture content:   10-25%        
  Ø      Estimated ash residue: 5-10%        
  Ø      Nominal capacity:   100Kg/hour batch load        
  Ø      Secondary chamber:  2 second @ 1100ºC        
  Ø      Environmental:    NEMA ACT           (EMCA) 1999        
                Clean Air Act 1999        
  BS3316 1987        
  Equipment Set      
  The Incinerator must comprise of: –        
  Ø      Manual Loading door (heavy duty steel door with appropriate refractory lining)        
  Ø      Horizontal solid hearth, refractory lined primary combustion chamber 800mm diameter x 2100mm long        
  Ø      Full sized bulk load/ash removal door        
  Ø      1 off diesel-fired ignition burner – temperature controlled        
  Ø      1 off combustion air supply fan and distribution system, automatic control        
  Ø      High capacity secondary combustion chamber 2 second @ 1100ºC with        
  Ø      1 off diesel-fired afterburner – temperature controlled        
  Ø      Control Panel – automatic operation        
  Ø      Temperature indication primary and secondary chambers 0-1200ºC. Both chambers must be insulated with refractory material (super duty 100mm thick firebrick with 25mm thick calcium silicate insulation)        
  Ø      Refractory lined flanged chimney to a height of 10M and it must be 3m above the height of any existing roof adjacent to the incinerator        
  Carried Forward To Collection Page.        
 

 

 

NOTE: WE REQUIRE TWO INCINERATORS. ONE        
ITEM DESCRIPTION UNIT QTY RATE KSHS.
B Diesel Tank:        
  To provide for diesel service tank (Capacity 400 litres) including level indicator

The tank should be connected to the incinerator at a higher level to enable free-flow of diesel from the tank to the incinerator. The connecting pipe must be a black pipe of approved gauge and diameter. Include other accompanying accessories and fittings

Item 1    
C Installation & commissioning works        
D Positioning of Incinerator: –

Provide lifting gears as forklift, gantry, rollers, and lifting jacks and position incinerator.

Item 1    
E Connect burners to fuel supply. No. 2    
F Chimney Installation:        
 G Composition of the chimney: –

Provide a chimney with scrubber (for filtration)

Provide lifting gear to hoist, erect and mount chimney, and provide supports slings as necessary. Allow for cutting of tree branches to facilitate the exercise.

The chimney shall be painted with approved heat resistant paint after installation.

Item. 1    
H Commissioning & Training:        
  Testing set operating parameters, training of operators and technical staff. Item 1    
I Commissioning Maintenance Contract        
  Before the expiry of the warranty/signing off, the suppler shall provide a one-year replacement service parts (e.g. filters, air filters), the Quarterly routine maintenance price per quarter for three (3) quarters. Maintenance contract proposal).  The maintenance contract price includes labour, transport and accommodation for the attending technicians. Item 3    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EVALUATION CRITERIA

Evaluation shall be carried out in four stages namely preliminary examination of documents for conformance with mandatory requirements, technical evaluation, site visit and commercial evaluation.

Stage One: Preliminary Examination

– Preliminary Evaluation under special condition of the tender. These are mandatory requirements.

This shall include confirmation that a bidder has complied with the special condition of tender above.

Failure to meet any one of the above requirements stated in the special conditions of the contract shall lead to automatic disqualification.

Stage Two: TECHNICAL EVALUATION (70 MARKS)

 

ITEM DESCRIPTION UNIT QTY MARKS ALLOCATED   MARKS RECEIVED  
           
  Incinerator        
  To supply and install the following    2NO.    
  Hospital Incinerator to Nema standards        
 

 

The following are the incinerator specifications :-        
           
A Ø      Waste type:      Mixed type 0,1,2,3 & 4 hospital/clinical bio hazard waste     35  
  Ø      Waste density:   125 to 350Kg/M³        
  Ø      Waste CV:        4000 KCAL/Kg        
  Ø      Moisture content:   10-25%        
  Ø      Estimated ash residue: 5-10%        
  Ø      Nominal capacity:   100Kg/hour batch load        
  Ø      Secondary chamber:  2 second @ 1100ºC        
  Ø      Environmental:    NEMA ACT           (EMCA) 1999        
                Clean Air Act 1999        
  BS3316 1987        
  Equipment Set      
  The Incinerator must comprise of: –        
  Ø      Manual Loading door (heavy duty steel door with appropriate refractory lining)        
  Ø      Horizontal solid hearth, refractory lined primary combustion chamber 800mm diameter x 2100mm long        
  Ø      Full sized bulk load/ash removal door        
  Ø      1 off diesel-fired ignition burner – temperature controlled        
  Ø      1 off combustion air supply fan and distribution system, automatic control        
  Ø      High capacity secondary combustion chamber 2 second @ 1100ºC with        
  Ø      1 off diesel-fired afterburner – temperature controlled        
  Ø      Control Panel – automatic operation        
  Ø      Temperature indication primary and secondary chambers 0-1200ºC. Both chambers must be insulated with refractory material (super duty 100mm thick firebrick with 25mm thick calcium silicate insulation)        
  Ø      Refractory lined flanged chimney to a height of 10M and it must be 3m above the height of any existing roof adjacent to the incinerator        
           
ITEM DESCRIPTION UNIT QTY RATE KSHS.
B Diesel Tank:        
  To provide for diesel service tank (Capacity 400 litres) including level indicator

The tank should be connected to the incinerator at a higher level to enable free-flow of diesel from the tank to the incinerator. The connecting pipe must be a black pipe of approved gauge and diameter. Include other accompanying accessories and fittings

Item 1 20  
C Installation & commissioning works        
D Positioning of Incinerator: –

Provide lifting gears as forklift, gantry, rollers, and lifting jacks and position incinerator.

Item 1 10  
E Connect burners to fuel supply. No. 2 5  
F Chimney Installation:        
 G Composition of the chimney: –

Provide a chimney with scrubber (for filtration)

Provide lifting gear to hoist, erect and mount chimney, and provide supports slings as necessary. Allow for cutting of tree branches to facilitate the exercise.

The chimney shall be painted with approved heat resistant paint after installation.

Item. 1 10  
H Commissioning & Training:        
  Testing set operating parameters, training of operators and technical staff. Item 1 10  
I Commissioning Maintenance Contract        
  Before the expiry of the warranty/signing off, the suppler shall provide a one-year replacement service parts (e.g. filters, air filters), the Quarterly routine maintenance price per quarter for three (3) quarters. Maintenance contract proposal).  The maintenance contract price includes labour, transport and accommodation for the attending technicians. Item 3 10  
  TOTAL      

100

 

 

Pass mark for technical evaluation is 70/100 marks

 

Stage Three: Site Visit

The evaluation committee will visit the premises of the bidders who are responsive to technical  evaluation stage to verify the authenticity of statutory document submitted; ascertain the accuracy of the information given in the tender documents, assess firm’s capacity, location, among others.

The Tenderer will be automatically disqualified where false or fraudulent Information is found to have been given.

 

Stage 4 Commercial Evaluation

Bids that pass the above three (3) stages shall be compared on the basis of prices / cost quoted and the lowest priced will be considered the lowest evaluated bid and subsequently recommended for award. Prevailing market prices will be used to determine the price responsiveness of the bidders.

 


SECTION V – SCHEDULE OF REQUIREMENTS

 

ITEM

NO

ITEM DESCRIPTION UNIT QTY. REQUIRED UNIT PRICE (KHS) REMARKS
1. Supply, Delivery, installation and commissioning of Incinerator in  

 

 

NO

 

 

 

 

 

 

1

   
2. Supply, Delivery, installation and commissioning of Incinerator  

 

 

NO

 

 

 

 

 

 

1

   

 

 

 

 

Signature of tenderer

 

Note: In case of discrepancy between unit price and total, the unit price shall prevail.

 

SECTION VI – STANDARD FORMS

 

  1. Form of tender
  2. Contract form
  3. Confidential Questionnaire form
  4. Tender security form
  5. Performance security form
  6. Bank guarantee for advance payment
  7. Declaration form

 

 

 

 

Brûleur d'une capacité de fusion de 500 kg / jour

en acinérateur avec 300 kg / heure par double filtre humide et sec. Incinérateur Pet Cadaver jusqu’à 80 kg, fonctionnant au gaz est préférable. brûleur à déchets pour animaux de compagnie d’une capacité d’environ 40 kg. Nous utiliserons cet objet pour faire fondre les cadavres d’animaux de compagnie de manière typique (pas malade aninal). Pouvez-vous s’il vous plaît me faire parvenir un devis pour le brûleur qui s’approprie pour le service Ville avec une population de 200 000 personnes comprenant d’autres déchets de la communauté générale à jeter. Fiche d’information sur les exigences techniques
Liste de contrôle et également les quantités de consommables appelées chaque mois
Liste et dépense de toutes les pièces de rechange nécessaires chaque année
Liste ainsi que les dépenses de toutes les pièces de rechange nécessaires dans 5 ans
Liste de contrôle et également les dépenses de toutes les pièces de rechange demandées dans 10 ans

2 incinérateurs, un avec une capacité de combustion de 500 kg / jour, un autre avec une capacité de fusion de 1000 kg / jour

1 x électrode

1 x filtre à carburant

1 x cellule photoélectrique

1 x pipeline polyvalent

1 x buse

1 x boîte de contrôle

инсинераторы на продажу

камера и горелка должны быть спроектированы таким образом, чтобы поддерживать минимальную температуру горения от 760 до 870 ° C.

(От 1400 до 1600 F). Система золоудаления должна состоять из автоматического непрерывного удаления золы в золоуловитель.

приямок охлаждается водой и удаляется конвейером.

Вторичная камера сгорания должна представлять собой цилиндрический тип с твердыми стенками и полом, горизонтальный, с огнеупорной футеровкой.

инсинератор, предназначенный для окисления (или сжигания) органических паров и газов. Регуляторы горелки и воздуха для горения должны быть

полностью автоматический, состоящий, как минимум, из электронного зажигания и всех необходимых блокировок и предохранительных устройств для

обеспечить безопасную работу. Камера и горелка должны быть спроектированы таким образом, чтобы поддерживать минимальную температуру горения.

минимум от 930 до 1200 ° C (от 1700 до 2200 F) с минимальным временем пребывания (или выдержки) газа 2,0 секунды. Удаление пепла

Система должна состоять, как минимум, из прямого ручного извлечения в бункер для сухого сбора.

Должны быть предусмотрены циклонные воздушные фильтры для удаления более крупных частиц. Циклонные воздушные сепараторы могут быть снабжены

вентиляторы с приводом для увеличения скорости газов внутри циклона для повышения эффективности сбора для меньших

частицы.

Heater YD-100 for Iraq


There are 03 sets Design YD-100 circulation to Iraq between year 2013 to 2014. The heater use for neighborhood a number of structure as well as construction sites in addition to all gas kind is diesel oil.

Items/Model YD-100
Burning Rate (kgs/Hour) 100 kgs/Hr.
Feed Capacity (kgs) 200 kgs
Equipment Weight 5300 kgs
Primary Chamber (Liters) 1200
Secondary Chamber (Liters) 500
External Dimensions (cm) 220x180x360
Internal Dimensions (cm) 130x100x90
Oil Tank(Liters) 300
Door Opening (cm) 55 x 80
Chimney (M) 10
Chimney Type Stainless Steel
Secondary Chamber  YES
Mix-Combustion Chamber YES
Smoke Filter Chamber YES
Combustion Fuel Oil/Gas
Residency Time 2.0 Sec.
Temperature Monitoring YES
1st. Chmaber Temperature 800℃–1000℃
2nd. Chmaber Temperature 1000℃-1200℃
Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


brûleur écologique

Établissement de soins de santé de 50 lits et aimerait également avoir votre référence pour un brûleur capable de gérer avec succès la charge d’un hôpital de 50 lits.Incinérateur pour poubelle brûlable (papier et organique) capacité d’outil (100/150 lts). Incinérateurs de déchets bio-médicaux,

Capacité: 50 kg par heure Brûleur à déchets médicaux Modèle TS50 (PLC) avec deux choix sur le carburant (gaz et aussi / ou brûleurs Diesel2
2 Thermocouple de niveau de température
5 mètres pour joint thermique
1 instance de contrôle de brûleur
1 ventilateur incinérateur écologique pour éliminer les sacs en polypropylène, nous avons 10 paquets par semaine